B + Stroke L K A + Stroke 2 x 4-M6 x 1.0 effective depth 10 M W Rod end male threads H1 Rod end nut C1 X L1 Rod end male threads mm Bore size (mm) C1 X H1 L1 20 25 18.5 12 14 M8 x 1.25 22.5 15 17.5 M10 x 1.25 Standard type mm A B C D E E1 E2 F H K L M Q W Bore size (mm) 20 25 Stroke range (mm) 15 to 50 36.5 32 7 10 36 18 21 15.5 M5 x 0.8 8 4.5 25.5 21 39 15 to 50 41.5 36.5 12 12 40 20 23.5
common 10 m or less Note 5) 33 OP Z phase pulse detector (Open collector) 1 P15R Plate SD 10 m or less 2 m or less Note 4) CN1 Emergency stop EMG 42 Servo ON SON 15 Note 4) CN6 RES 19 Reset 3 MO1 PC 17 Proportion control Analog monitor 1 10 VDC 1 LG TL 18 External torque limit selection 10 VDC Analog monitor 2 2 MO2 LSP 43 Forward rotation stroke end LSN 44 Reverse rotation stroke end 2
Note 3) Not used for 10 and 12. 15-16-9 10 Series ASR/ASQ Flow Characteristics Pressure Valve: Series ASR (Inlet pressure: 0.5 MPa) ASR430F ASR530F ASR630F 20 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Effective area mm2 Effective area mm2 Effective area mm2 400 6 12 1000 15 300 4 8 500 10 200 500 4 2 5 100 10 5 0 10 5 0 10 5 0 Number of needle rotations Number of needle
L 60.5 3 48 2 85.5 5 73 4 110.5 7 98 6 135.5 9 123 8 160.5 11 148 10 185.5 13 173 12 210.5 15 198 14 235.5 17 223 16 19 248 18 20 260.5 285.5 21 273 No.
Power supply for solenoid valves: 24 VDC +10%/-5% 68 No.EX-OMS0014-A Fault No. 10 Fault Possible cause Investigation method Countermeasures Tighten the branch cable connection. (if there is a broken wire, replace the cable) Power supply for input and control: 24 VDC 10% SI unit PWR LED is OFF. Check the branch cable connections and check for broken wires.
67.1 8 12 5 M14 x 1.5 19 6 12 92.6 13.5 21.9 15 88.2 73.2 10 17 6 M20 x 1.5 27 6 18 105.2 17 31.2 25 124 99 12 24 8 M27 x 1.5 36 6 25 147 23 41.6 The dimensions of H/L type are the same.
Pushing force 0.9 0.9 Pushing force Pushing force 0.9 4 4 4 Thrust setting value: 3 Thrust setting value: 2.8 Thrust setting value: 2.6 0.7 0.7 0.7 3 3 3 0.4 0.4 0.4 2 2 2 Thrust setting value: 1 Thrust setting value: 1 Thrust setting value: 1 0.2 0.2 0.2 1 1 1 0 0 0 0 0 0 0 2 4 6 8 10 Pushing position [mm] 0 5 10 15 20 Pushing position [mm] 0 5 10 15 20 25 30 Pushing position [mm] Pushing
area So [mm] 10 1/4,3/8 20 2000 6 10 1/4, 3/8 2500 7.5 =0.7 10 1/4, 3/8 0.5 3000 9 10 0.1 0.3 6 1/4,3/8 500 2.5 8 1/4, 3/8 1000 5 0 10 1/4, 3/8 1,000 2,000 3,000 25 1500 7.5 Maximum speed Vmax [mm/s] 10 1/4 2000 10 32 2500 3000 12.5 15 1/4 1/4 30 6 10 1/4, 3/8 =0.7 500 4 20 0.5 0.1 0.3 10 10 1/4, 3/8 32 1000 8 1500 2000 2500 3000 12 16 20 24 1/4,3/8 3/8 3/8 3/8 0 1,000 2,000 3,000 Maximum
area (mm2) 1.5 2 3.5 4.5 7 6.5 10 14 16 21 Note) Flow rate values are measured at 0.5 MPa and 20C. 15-9-49
PA06 1 100 35 100 (10) (7) (10) Electronic gear denominator *3.
0.7 0 0 0 5 10 15 20 0 5 10 15 20 Flow rate (L/min) Flow rate (L/min) Pressure Loss in FacilityWater Circuit
Auto Switch Mounting Groove Dimensions M3 x 0.5 5 1.7 15 33 4 20 Accessory option: Hexagon socket head screw (special screws) 3.3 2-2.5H9 +0.025 0 depth 2.5 3 9 9 2-M4 x 0.7 thread depth 5 Groove for auto switch mounting 14 14 Mounting thread 15 38 12-3-15 16 Series MHF2 Dimensions MHF2-12D1 3H9 +0.025 0 depth 3 42 3H9 +0.030 0 depth 3 2-M4 x 0.7 thread depth 10 Mounting thread 4 58 4 40
14 Mounting thread 15 38 12-3-15 16 Series MHF2 Dimensions MHF2-12D1 3H9 +0.025 0 depth 3 42 3H9 +0.030 0 depth 3 2-M4 x 0.7 thread depth 10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Mounting thread 4 58 4 40 68 M5 x 0.8 2-M4 x 0.7 thread depth 5 20 54 Finger
(inch) M Weight (g) A D L1 L1 Applicable tubing M 10 16 18.3 18 3.5 KQGL03-32 10-32UNF 10.6 20.5 18 5/32 12 19.5 20.7 21 4.2 KQGL03-N01S D NPT1/8 A 10 17 20.5 25 3.5 KQGL07-32 10-32UNF L2 12 13 20.5 22.1 22.9 27 18.8 KQGL07-N01S 1/4 NPT1/8 H Connection thread 9 14 24.5 25.2 35 KQGL07-N02S NPT1/4 12 21.9 25.3 37 KQGL09-N01S NPT1/8 (In case of R) 15 14 25.9 24.9 27.6 45 20.9 21.6 KQGL09-N02S
1 ALARM ESTOP WAREA AREA INP SETON SVRE BUSY 2 ALM FG READY 3 4-7 4byte 8-9 2byte 20Byte 10-11 2byte 12-15 4byte 16 1 17 2 18 3 19 4 Byte0,1 Byte Bit 0 OUT0 DRIVE No.
T) View Z (mm) Dimensions A B C D M N T U V Model LVQ20-S-2 LVQ30-S-2 LVQ40-S-2 LVQ50-S-2 LVQ60-S-2 25.5 46 31.5 58 7 15 35.3 10.6 7 23.5 47 29.5 59 7 15 36.9 16.5 10 23.5 47 29.5 59 7 20 37.9 22 35 70 41 82 7 20 64 25 17 35 70 41 82 7 20 66 32 17-5-69 8 Series LVQ Dimensions With flow rate adjustment & by-pass High back pressure spec. with flow rate adjustment & by-pass N.C. valve M N
2) 2 15 + 45 D-C7 D-C80 10 15 50 50 + 45 (n 2) (n = 2, 4, 6, ) D-H7 D-H7W D-H7BAL D-H7NF (n 2) 2 15 + 45 10 15 60 + 45 (n 2) 60 (n = 2, 4, 6, ) D-C73C D-C80C D-H7C (n 2) 2 15 + 50 65 + 50 (n 2) 10 15 65 (n = 2, 4, 6, ) D-B5 D-B64 D-G5NTL (n 2) 2 15 + 50 75 + 55 (n 2) 10 15 75 (n = 2, 4, 6, ) (n 2) 2 20 + 50 D-B59W 75 + 55 (n 2) 15 20 75 (n = 2, 4, 6, ) D-A3 D-A44 D-G39 D-K39 100
2) 2 15 + 45 D-C7 D-C80 10 15 50 50 + 45 (n 2) (n = 2, 4, 6, ) D-H7 D-H7W D-H7BAL D-H7NF (n 2) 2 15 + 45 10 15 60 + 45 (n 2) 60 (n = 2, 4, 6, ) D-C73C D-C80C D-H7C (n 2) 2 15 + 50 65 + 50 (n 2) 10 15 65 (n = 2, 4, 6, ) D-B5 D-B64 D-G5NTL (n 2) 2 15 + 50 75 + 55 (n 2) 10 15 75 (n = 2, 4, 6, ) (n 2) 2 20 + 50 D-B59W 75 + 55 (n 2) 15 20 75 (n = 2, 4, 6, ) D-A3 D-A44 D-G39 D-K39 100
2) 2 15 + 45 D-C7 D-C80 10 15 50 50 + 45 (n 2) (n = 2, 4, 6, ) D-H7 D-H7W D-H7BAL D-H7NF (n 2) 2 15 + 45 10 15 60 + 45 (n 2) 60 (n = 2, 4, 6, ) D-C73C D-C80C D-H7C (n 2) 2 15 + 50 65 + 50 (n 2) 10 15 65 (n = 2, 4, 6, ) D-B5 D-B64 D-G5NTL (n 2) 2 15 + 50 75 + 55 (n 2) 10 15 75 (n = 2, 4, 6, ) (n 2) 2 20 + 50 D-B59W 75 + 55 (n 2) 15 20 75 (n = 2, 4, 6, ) D-A3 D-A44 D-G39 D-K39 100
(The rack has a specified mounting direction, so this should be checked when removing it from the body.) 17 15 3 10 14 27 11 5 12 19 9 12 14 1 11 27 4 2 6 15 4 43 - Assembly procedure 1. Apply the grease provided in the seal kit to parts shown in Table (19).