SMC Corporation of America
Elite Part Number Search
Search Results "10-CJ2B10-30"

Without lead wire (housing and 3 sockets) ZS-10-A With lead wire ZS-10-5ALead wire length Note) When requiring a switch with lead wire of 5 m, indicate separately the model numbers of the connector type switch without lead wire and the connector assembly with 5 m lead wire. Nil 30 50 0.6 m 3 m 5 m Example) ZSE2-0R-15CN . 1 pc.

Moreover, depending on the operating direction, the allowable load mass may be different from the maximum load mass. 10 (1.71 1.3 x 103 x ST) CY1L20 CY1L25 CY1L32 Model 30 10 (1.98 1.3 x 103 x ST) 10 (2.26 1.3 x 103 x ST) = 20 12 2.

5 6 7 8 9 1 0 1 11 2 1 31 41 5 7 8 9 10 11 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R20 CY3R40 500 200 300 100 200 50 100 20 30 40 50 30 10 Useable range 10 5 5 Useable range 1 0 1 2 3 4 5 6 1 7 8 9 10111213 0 1 2 3 4 5 6 7 8 9 1 0 1 11 2 1 31 41 5 Distance from cylinder shaft center Lo (cm) Distance from cylinder shaft center Lo (cm) CY3R25

A B 3 5.5 7 7 15 60 65 + 45 (n-2) D-H7, D-H7W D-H7F 30.5 28.5 30 30 n-2 2 15 + 50 ( ) (n = 2, 4, 6...) Approx. Hs 30.5 35 40.5 47.5 D-H7C 15 65 10 65 + 50 (n-2) A B Approx. Hs 3 5.5 7 7 n-2 2 D-H7C 31.5 28.5 30 30 15 + 50 ( ) (n = 2, 4, 6...)

90 5 90 10 180 10 90 5 90 10 180 10 90 5 90 10 180 10 90 5 Air (Non-lube) Fluid 1.05 1.5 Proof pressure (MPa) 5 to 60C Ambient and fluid temperature 0.15 to 0.7 0.2 to 0.7 0.15 to 1.0 Operating pressure range (MPa) Rotation time adjustment range (sec/90) 0.07 to 0.3 Allowable radial load 40 N 50 N 60 N 20 N 30 N 60 N 80 N 15 N Shaft load Allowable thrust load 2 15 N 30 N 40 N 10 N Allowable

Thread type Nil Rc G F N NPT Dimensions NPTF T Applicable fitting d Model A L D Gasket KQ2P-04 16 32 6 4 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 Series Round head combination screw Gasket 22 16 18 20.5 22 12 6 8.5 10 11.5 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 10 5/32" 1/4" 5/16" 3/8" 43 32 35 39 43 Caution SX3000 SX3000-22-2 (M2 x 24) M3 x 30 (Matt nickel plated) M4 x 35 (Matt nickel plated

(Displays 0 when the value is (Displays 0 when the value is below 10 L/min) below 20 L/min) 20 to 1050 L/min 40 to 2100 L/min 2.0 0 to 2%F.S. (Displays 0 when the value is (Displays 0 when the value is below 20 L/min) below 40 L/min) 30 to 1050 L/min 60 to 2100 L/min 3.0 0 to 3%F.S.

Note 7) The display unit is comformed to CE mark. 16-11-9 6 Series PF2A Flow Characteristics (Pressure loss) PF2A710/510 PF2A750/550 PF2A711/511 3.0 1.0 10 Pressure loss (kPa) Pressure loss (kPa) Pressure loss (kPa) 2.5 0.8 8 2.0 6 0.6 1.5 0.4 4 1.0 0.2 2 0.5 Flow rate (l/min) 0 100 10 25 50 75 0 1 10 5 2.5 7.5 0 5 10 15 20 25 30 40 35 45 50 Flow rate (l/min) Flow rate (l/min) PF2A721/521

(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 42 50 54 64 63 K 5.5 5.5 6 7 7 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Standard stroke (mm) 5, 10 5, 10 5, 10, 15, 20 5, 10, 15, 20 5, 10, 15, 20 M5 x 0.8

(mm) H1 6 7 8 11 11 H 36 40 45 53 56 GY 5 5.5 7 8 10 GX 10 8.5 9 11.5 11.5 EY 26 42 54 64 72 D 12 14 16 20 20 B1 17 19 22 27 27 C 54 68 86 104 124 B 24 28 32 39 50 BY 7 8 9 9 12 AL 19.5 23.5 27 32 32 BX 9 6.5 8 10 11 ET A 22 26 30 35 35 BS 42 50 54 64 63 K 5.5 5.5 6 7 7 BT Model MUB25 MUB32 MUB40 MUB50 MUB63 Standard stroke (mm) 5, 10 5, 10 5, 10, 15, 20 5, 10, 15, 20 5, 10, 15, 20 M5 x 0.8

10 10 10 54 32 26 11 22 20 44 16 11 15 6 27 71.5 60 42 22 21 150.5 8 M8 x 1.25 25 to 800 25 to 650 50 35 12 13 10 59 40 27 11 27 21 52 20 10 17 9 32 80.5 70 46 24 28.5 162.5 11 M8 x 1.25 25 to 800 25 to 650 60 35 15 18 10 67 40 26 27 23 64 20 13 17 9 32 98.5 85 48.5 24 28.5 174 11 M10 x 1.25 13.5 25 to 750 25 to 600 70 40 17 23 14 72 52 30 32 23 78 25 15 21 11 37 117.5 102 55 26.5 36 189

Thread type Nil Rc G F N NPT Dimensions NPTF T Applicable fitting d Model A L D Gasket KQ2P-04 16 32 6 4 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 Series Round head combination screw Gasket 22 16 18 20.5 22 12 6 8.5 10 11.5 KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 10 5/32" 1/4" 5/16" 3/8" 43 32 35 39 43 Caution SX3000 SX3000-22-2 (M2 x 24) M3 x 30 (Matt nickel plated) M4 x 35 (Matt nickel plated

Specification for Option L 10 1 Safety instructions . 10 1 10 2 Specification . 10 1 10 3 Maintenance . 10 2 Chapter 11 Specification for Option M 11 1 Safety instructions . 11 1 11 2 Specifications . 11 2 11 3 Cautions for handling the motor type auto drain . 11 2 11 4 Electric circuit . 11 2 Chapter 12 Specification for Option R 12 1 Safety instructions . 12 1 12 2 Specifications . 12

19 6 turns PF3W720S 112 54 63.6 (Max. 68.6) 74.2 34 62.5 18 13.6 2.7 depth 10 19 6 turns PF3W740S 142 71 75.25 (Max. 81) 94.5 44 79 28 16.8 2.7 depth 10 28 7 turns Symbol Bracket dimensions Model S T PF3W704S 56.5 22 PF3W720S 60.5 22 PF3W740S 78 30 -87No.PF-OMM0005-N PF3W704/720/740 (With temperature sensor and flow adjustment valve) Basic type and flow adjustment valve and temperature sensor

For details, refer to 3 point preset counter/CEU1 on page 10-12-30, and Multi counter/CEU5 on page 10-12-27 respectively. 10-12-54 Stroke Reading Cylinder with Brake CE2 Wiring with External Equipment 1. Wiring of driving power of controller 2.

Model determination 61 Series REBR Model Selection 2 Design Parameters 1 Selection Method REBR25 REBR32 REBR15 500 400 300 200 300 200 Allowable driving force Fn (N) Load weight W (kg) Allowable driving force Fn (N) Allowable driving force Fn (N) 50 100 100 40 30 40 50 20 30 40 50 30 20 20 Usable range 10 10 10 Usable

For 20A/20B 25 5 1.5 4 x 2.6 Depth 7 or less Atmospheric vent port 30 20 30 20 Lead wire with connector M5 x 0.8 Thread depth 3.5 01 4 x 2.6 Depth 7 or less Atmospheric vent port 15.2 R1/8 7.2 N01 NPT1/8 A Piping specification Port size A 01 R1/8 Width across flats 10 N01 NPT1/8 Width across flats 12 20 ZSE20(F)/ISE20 Series Dimensions With bracket ZSE20(F) ISE20 Option 2 30 A1 25 20 Bracket

30 30 0.1MPa 20 20 20 0.15MPa 0.15MPa 0.15MPa 10 10 10 0.2MPa 0.2MPa 0.2MPa 100 200 300 0 100 200 300 0 100 200 300 0 Detection distance (m) Detection distance (m) Detection distance (m) Example 1) When requiring 300m detection, select the detection nozzle of 1.0 with supply pressure 0.2MPa.