M12 x 1.75 27 14 34 35 34 100 125 15 100 250 16 112 170 M27 x 2 38 6.5 140 140 112 35.5 80 35 27 19 M14 x 2 27 16 34 35 34 100 160 17 110 279 18 140 197 M33 x 2 42 9 174 174 140 45 100 38 36 22 M16 x 2 28 18 38 40 43 108 (mm) Bore size (mm) Y ZZ P R S T V W X 40 8 246 1/4 37 114 11 7.5 8 27 50 10 262 3/8 43 116 11 10 9 30 63 10 280 3/8 47 120 11 12 10 37 80 13 312 1/2 57 132 11 16 13 40 100
I/O cable JX-CI-E--S Cable length (L[m]) 1 1.5 *The terminal on PLC 3 3 5 5 10 10 Straight connector type /JX-CIS-E-*-S Connector type L (45.8) 2 3 S Straight 1 4 A Angle (15) 8Core 5 7 (35) 6 (5.8) M12 8-pin socket A code Normal key (29.1) Angled connector type /JX-CIA-E-*-S *Angled connector type cannot be used for motor mounting position:parallel type. (15) Electric actuator (parallel
Circuit / Operation Principles . 7 2 Chapter 8 Specification for Option C 8 1 Specifications . 8 1 8 2 Precautions for the installation and handling of the product . 8 1 Chapter 9 Specification for Option K 9 1 Safety instructions . 9 1 9 2 Specifications . 9 1 Chapter 10 Specification for Option L 10 1 Safety instructions . 10 1 10 2 Specification . 10 1 10 3 Maintenance . 10 2 Chapter
AXT632-106A-1 AXT632-106A-2 Note) Each of the above part numbers is for two screws, which are to be ordered by 10 units. Order is accepted in 10 units.
K 11 8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46 60 70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20
Valve diagnostics 1 Table. 5-4 Valve diagnostics 1 Bit Description Explanation 0 Valve 0, 1 diagnostics 0: No error, 1: Short circuit 1 Valve 2, 3 diagnostics 0: No error, 1: Short circuit 2 Valve 4, 5 diagnostics 0: No error, 1: Short circuit 3 Valve 6, 7 diagnostics 0: No error, 1: Short circuit 4 Valve 8, 9 diagnostics 0: No error, 1: Short circuit 5 Valve 10, 11 diagnostics 0: No error
RX RX RX RX RX RX RX RX (n+2)8 (n+2)9 (n+2)7 (n+2)6 (n+2)5 (n+2)4 (n+2)3 (n+2)2 Point table No. output 3 (PT2) RX(n+2)4 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 2 0 0 Point table No. output 4 (PT3) RX(n+2)5 1 1 0 0 0 0 0 3 0 0 1 4 0 0 0 0 0 0 Point table No. output 5 (PT4) RX(n+2)6 Point table No. output 6 (PT5) RX(n+2)7 1 1 1 1 1 254 1 1 0 1 255 1 1 1 1 1 1 1 Point table No. output 7 (PT6) RX(n+2)8
1/2 163 125.3 72.8 1/2 163 125.3 79.1 1/2 163 125.3 79.1 3/4 172.2 134.5 78.7 3/4 172.2 134.5 85 3/4 172.2 134.5 85 1 196.2 158.5 89.7 1 196.2 158.5 96 1 196.2 158.5 96 389 Related Products Nozzles for Blow Nozzle with Self-Align Fitting / KN (mm) Nozzle diameter D Connection size L1 L2 With across flats H1 H2 Model KN-10-400 KN-10-600 KN-12-400 KN-12-600 KN-16-400 KN-16-600 KN-20-400 KN
ARM 2 2 3 3 3 4 4 5 5 6 6 2 2 2 3 3 4 4 5 5 6 6 1 2 1 2 3 1 2 1 2 1 2 A B C A B A B A B A B 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 19 x 16 12 x 10 25 x 22 19 x 16 1/4" x 5/32" 3/16" x 1/8" 1/8" x 0.086" 3/8" x 1/4" 1/4" x 5/32" 1/2" x 3/8" 3/8" x 1/4" 3/4" x 5/8" 1/2" x 3/8" 1" x 7/8" 3/4" x 5/8" SMC SMC SMC ARP P U Panel mount union Union IR-A IR SMC IRV : Basic size : With reducer
Coil voltage One-touch fitting for 6 One-touch fitting for 8 One-touch fitting for 10 One-touch fitting for 12 1 2 3 5 6 9 (1) 100 VAC (50/60 Hz) 200 VAC 110 VAC 24 VDC 12 VDC Other LQ Valve Type (A) 2 N.C.
1000 mm, 1500 mm (10, t = 1.5) Thread size connected to the outlet piping endOpen How to calculate 1.
Minimum auto switch mounting stroke (mm) Bore size (mm) Auto switch Number of auto switch mounted 20 25 32 40 50 63 80 100 model 1 pc. 5 D-A9(V) D-M9(V) 2 pcs. 10 1 pc. 5 N o t e 2 ) D-M9W(V) D-M9AV 2 pcs 10 1 pc. 5 N o t e 2 ) D-M9A 2 pcs. 10 N o t e 2 ) 1 pc. 5 N o t e 1 ) 5 D-Z7/D-Z80 D-Y59/D-Y7P 2 pcs. 10 1 pc. 5 D-Y69 D-Y7PV 2 pcs. 5 1 pc. 5 N o t e 2 ) D-Y7W(V) D-Y7BA 2 pcs. 10 N o
Description(Extract) Initial input value Input range LEG25 LEG32 LEG40 Controller ID 1 1 to 64 Note1) IO pattern 1: 64 Acceleration / deceleration pattern 1 S-motion ratio 0 Stroke (+), Note 2), 3) 1000.00 10 Stroke (-), Note 2), 3) -1000.00 -10 Maximum speed 250 200 150 Step data input limit: Max. speed of each product Maximum acceleration / deceleration 5000 to 5000 Default In positioning
Output voltage Linearity: 1% F.S. Linearity: 1% F.S. Linearity: 1% F.S. Output impedance Approx. 1 k Analogue output 2.4 to 20 mA 3.2 to 20 mA 4 to 20 mA 2.5% F.S. 2.5% F.S. 2.5%F.S. Output current Current output 3 Linearity: 1% F.S. Linearity: 1% F.S. Linearity: 1% F.S.
11) (0.5) 10 5 5 2-1 (Bleed port) 10 10 7 7 2-1 (Bleed port) M3 x 0.5 (Piping port) 28 M5 x 0.8 (Piping port) 3 position closed center/exhaust center/pressure center SYJA3 20-M3(-F) 3 position closed center/exhaust center/pressure center SYJA3 40-M5 3 4 5 3 4 5 7.1 9 10 2-M3 x 0.5 (Pilot port) 1.8 10 4 A B 1.5 7 8.2 19 2-M3 x 0.5 (Pilot port) (For mounting) 2-3.2 22 3 49 2.5 (For mounting
Suitable screw torque (Nm) Body size M3 0.07 M5 0.3 1/8 1 1/4 1.5 3/8 4 1/2 10 15-8-6 Flow Control Equipment Precautions Series ASN2 Handling of One-touch Fittings Caution Selection 1. Refer to page 15-1-11 for One-touch Fitting. Warning 1.
Port size 10 8 6 12 1/8" 1/4" 3/8" 5/32" 3/16" 5/16" 4 ASD230F-M5 ASD330F-01 ASD430F-02 ASD530F-02 ASD530F-03 ASD630F-04 M5 x 0.8 R 1/8 R 1/4 R 1/4 R 3/8 R 1/2 ASD230F-U10/32 ASD330F-N01 ASD430F-N02 ASD530F-N02 ASD530F-N03 ASD630F-N04 10-32 UNF NPT 1/8 NPT 1/4 NPT 1/4 NPT 3/8 NPT 1/2 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure
Note 8) : Combination available for options : E1, E2, E3, E4. 1094 Direct Operated Precision Regulator Series ARP20 to ARP40 10211021Direct Operated Precision Regulator with Backflow Function Series ARP20K to ARP40K 10211021Specifications Model 10-ARP20 (K) 10-ARP30 (K) 10-ARP40 (K) 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Port size Air Fluid 1.2 MPa Proof pressure 0.7 MPa Maximum operating pressure
Note 8) : Combination available for options : E1, E2, E3, E4. 1094 Direct Operated Precision Regulator Series ARP20 to ARP40 10211021Direct Operated Precision Regulator with Backflow Function Series ARP20K to ARP40K 10211021Specifications Model 10-ARP20 (K) 10-ARP30 (K) 10-ARP40 (K) 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Port size Air Fluid 1.2 MPa Proof pressure 0.7 MPa Maximum operating pressure
54 56 61 74.5 84 9 10 11 13.5 15.5 19 25 25 29 35.5 45.5 55.5 15 21 27 33 37 40 2 2 2 2 2.5 2.5 1 1 1 1 1.5 1.5 5 10 10 10 15 15 11 11 12.5 15 18 21 M8 x 1.25 M8 x 1.25 M8 x 1.25 25, 50 75, 100 125, 150 175, 200 124 106 48 122 90 110 M8 x 1.25 M8 x 1.25 M8 x 1.25 140 120 56 138 100 124 M10 x 1.5 M10 x 1.5 M10 x 1.5 150 130 69 148 110 132 M10 x 1.5 M10 x 1.5 M10 x 1.5 188 160 88 185 140 166