SMC Corporation of America
Elite Part Number Search
Search Results "VVEX2-2-4-02F"

PRODUCT NAME FREE MOUNT CYLINDER MODEL/ Series (D)U SERIES (D)UK SERIES (D)UW SERIES (D)UKW SERIES 1/10 Contents Safety Instructions 2 1. Specifications 4 2. Installation and Handling 6 3. Maintenance 9 4. Basic Circuit for Cylinder Operation 9 5.

Normally open Material Solenoid coil Body Seal Brass/BC6, Stainless steel NBR, EPDM, FKM Coil: Class B, Class H Model Rated voltage AC Standard Option 100 V, 200 V 48 V, 110 V, 220 V, 240 V Orifice size (mm) Model Port size Rc 1/4, 3/8 10 VXZ223 2 0 Rc 1/2 15 VXZ224 2 DC 24 V 12 V 0 Standard Option Rc 3/4 20 VXZ235 2 0 Rc 1 25 VXZ236 2 0 5 Series VXZ22/23 Pilot Operated 2 Port Solenoid

10 S Q: 4 Q: 6 M14 x 1 Y Model R S R S ZPR10F10-0-A10 H I J Hexagon width across flats 19 Stroke 1.5 ZPR13F10-0-A10 20 10.4 20.6 12.8 21.6 +10 +38 2 +28 I 5 ZPR16F10-0-A10 30 +20 +48 40 +30 +84 +54 50 +40 +94 5 J Hexagon width across flats 12 Applicable tubing O.D.Q H R Hexagon width across flats 12 F Hexagon width across flats 3 E D C 3 2 A B Stroke: 20 to 50 mm Dimensions: 10 mm Stroke

/4 115/1/60 1 NPT 232 R134a 17.7 21.3 19.9 3.3 8.3 82 PDE30-S 137 4.4 5.7 1 230/1/60 1 NPT 174 R134a 21.3 26.4 25 3.1 10.2 126 PDE40-S 137 5.1 6.5 1 1/4 230/1/60 1 1/4 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 168 PDE50-S 168 6.3 8.2 1 1/2 230/1/60 1 1/2 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 207 PDE60-S 200 7.2 10.4 1 3/4 230/1/60 2 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 227 PDE75-S 235 7.5 10.7

Pressure gauge port size Port size Model AR425/435 AR625/635 AR825/835 AR925/935 1/4, 3/8, 1/2 3/4, 1 1 , 1 2 80 98 126 160 145.5 155 216 241 3 7 5 10 1/4 1/4 1/4 1/4 39.5 43 75 90 50.0 85 48 52 80 90 B24P B25P 67 78 110 140 73 78.5 94.5 4 1 2 1 109.5 680

Rc 1/8 pilot port 2-Mounting hole Port size Rc (EXH port) Port size 2-Rc (IN, OUT port) IN, OUT EXH Port size Rc A Model Mounting hole C D E F G H K L B J 3 8 1 2 3 4 VPA3145 71 3 4 85 14 52 55 93 32 87.4 36 71 80 8.5 3 4 VPA3165 82.6 1 4 1 1 110 17 68 75 118 45 113 36 71 95 8.5 1 4 1 1 1 1 4 VPA3185 118 1 2 132 14 80 95 140 52 140 41 81 105 13 2 2 5-5-26

Accumulation stop Accumulation starts button press for 2 sec. Unlock Lock button press. 1: Operate only the product with unit selction function (Model indication: without M). 2: Operate only the PF2A2 series. 3: Depend on the setting of switch operation in initialize mode. 4: Displayed in turn. 5: Flow display is available for PF3W5 series.

How to Order 1 2. Model 1 3. Specifications 1 4. Standard strokes 2 5. Intermediate stroke 2 6. Weights 2 7. Weights of moving parts 3 8. Allowable Kinetic Energy 3 9. Precautions on Selection 4 10. Precautions on Design 4 11. Mounting Methods 5 12. Piping 7 13. Operating Environment 8 14. Speed Control 8 15. Troubleshooting 9 16. How to exchange seals 10 17. Construction 12 18.

Flow chart . 5 2. SigmaWin+ Preparation . 6 2.1 SigmaWin+ . 6 2.1.1 USB driver Installation Method .6 3. SigmaWin+ Basic Setting . 6 3.1 Start up the SigmaWin+ . 6 4.

Fig.3-4 [Ex.-4] In wrong example shown of Fig. 3-2 [Ex.-2] (with external slider mounted directly on load base), the misalignment between guide (orbit) and cylinder is not compensated and may induce operating failure. To eliminate the misalignment and deflection of cylinder by self-weight, clearance is provided between mounting bracket and cylinder as shown on correct example.

C (F) note 2 -5~+50 (+23~+122) -20~+60 (-4~+140) Max.

(optional) 2-Rc 1/4 ATM port, OUT port 4-M x 0.8 thread depth 6mm through Mounting hole OUT 2 G 15 19 R3.5 n36 25 7 (10) 30 L-bracket INI-398-0-6 (optional) 2-Rc 1/4 ATM port, OUT port (7) 36 SMC Pneumatics, Inc.

Option/Semi-standard symble:When more than one specification is required, indicate in alphanumeric order. 1 3 4 5 6 2 Symble Description 0.020.2MPa 0 0 0 0 Set pressure range 1 1 1 1 0.020.4MPa 2 2 2 2 0.020.8MPa + 1 Exhaust direction 0 0 0 0 Bottom exhaust + 2 Nil Nil Nil Nil Rc Pipe thread type NPT N N N N F F F F G + 3 Port size 01 01 01 01 1/8 + 4 Nil Nil Nil Nil Without pressure gauge

frequency [Hz] 70 50 150 100 Valve Construction 2-position single 2-position single Standard 5-port specification Made to Order 3-port specification (-X1) q w 3 (EB) 1 (P) 5 (EA) 3 5 1 3 5 1 2 4 2 4 Component Parts No.

4.5 (same on reverse side) 4 8 6 11 22.5 (13) (10 + 1/2ST) 4 Model ST 13 + ST 45 + ST 58.5 + ST 10 + 1/2ST CXS6-10-XB19 10 23 55 68.5 15 CXS6-20-XB19 20 33 65 78.5 20 CXS6-30-XB19 30 43 75 88.5 25 CXS6-40-XB19 40 53 85 98.5 30 CXS6-50-XB19 50 63 95 108.5 35 CXS10--XB19 17 S ZZ 15 1 10 7 SS 2-3.4 through 2-6.5 counter bore depth 3.3 2-2.5 x 14l AW (spring pin) 20 Z 9 5 1 35 0.2 35 0.2 33.6

industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 : ) JIS B 8433-1993: *2) , 1. 2. 3. 1. 2. 3. 4. 4/11 FGX-OM-L007-C / 1 1.5 () 5/11 FGX-OM-L007-C FGD Series FGD , 0.5MPa 4080 oC 40 oC IN/OUT 0.1MPa , U IN/OUT 6/11 FGX-OM-L007-C 1. 1-1. 1 2 (1) 3 (2) 4 (3) (4) 5 (5) 6 (6) 7 (7) 8 (8) 9 (9) (10) (2 FGD*B ) 10 (11) (12) 18 (13) (14) 11 (15) (16) (17

P 1 Silencer VEX Solenoid Tightening Torques for Silencers Applicable tightening torque (N.m) 12 to 14 Connection thread AN 1 4 22 to 24 3 8 28 to 30 1 2 28 to 30 3 4 36 to 38 40 to 42 1 4 1 2 48 to 50 48 to 50 R R R R R 1 R 1 R 1 R 2 Inlet pressure for silencer AMC 4.

Switch mounting bracket Note 2) 0.2 25 25 13 Fulcrum 12 12 20 10 10 2 x M10 x 1.5 through 45 F 30 90 110 107 Note 3) 2 x 4 x M10 x 1.5 depth 12 70 0 2 x 2 x 8H7( ) depth 12 0.015 1 193 25 52 380 (58.7) 95 133 70 0.05 (70) 85 75 270 0.3 (173) Rc1/ 4 (10) 100 100 Unclamp side port (30.2) (30.2) 306 139 360 Limit switch Note 1) Rc1/ 4 Clamp side port 0 4 x 8H7( ) through 0.015 82 0.05 143 115

AMF150 AMF250 AMF350 AMF450 AMF550 AMF650 AMF850 Rated flow (l/min (ANR))(1) 200 500 1000 2000 3500 6000 12000 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 1, 11/2 11/2, 2 3/4, 1 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow capacity at a pressure of 0.7MPa.