Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, CG5 CYLINDER, STAINLESS STEEL, SD, 100MM CG5 DOUBLE-ACTING, 28 lb
. -28- LEY63 LEY63D Lead symbol A B C L A B C Series Lead 5(2.86) 20 10 5 20 10 5 (Including pulley (Pulley ratio 4/7) ratio) Parameter *1,*2 Para.
. -28- Recommended Parameter Values [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Series Lead symbol H A B H A B T Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para. Initial value Recommended value No.
For safety , use the external Regenerative resistors with thermoswitches. 28 - 5. Trial Operation (SigmaWin+) The procedure of the test driving with setup software (SigmaWin+) is shown below. When use the setup software (SigmaWin+), order USB cable (LEC-JZ-CVUSB) separately. 5.1 Communications setting for PC When SigmaWin+ is initially started, the Connect dialog box appears.
After the DRIVERs have been successfully connected to SigmaWin+, a list of the connected DRIVERs will appear on the screen. 28 - DRIVER Selection Box 3. Select the DRIVER to be connected and then click Connect, or just double-click the DRIVER to be connected. The SigmaWin+ main window will appear.
If necessary, re-application of power supply should be done when 5s or more passes after PWR indicator lamp goes off. 28 3.Stroke learning General 3 positions 5 positions General 3-1 By push of over 3s at least, the product comes into learning mode and starts stroke learning. 3-2 Confirm 2 indicator lamps MOTOR and END are blinking.
Therefore the INF output may be activated when the pushing force differs from the set "Thrust Setting Value". 28 - INFP signal The output turns ON when the current Card Motor table position is within the positioning repeatability range (LAT3 is 0.09 mm, LAT3F is 0.005 mm) of the target position. The output conditions for each operation mode are similar to those for the INP signal.
Pulse train signal specifications (Open collector input and differential input are common) 5 s or more 24 V 21.6 V to 26.4 V 5 V 4.75 V to 5.25 V PP3s or less 5 s or more 3s or less 16 s or more 28 - 7.4 Parallel I/O signals (Pulse Input Type) (1) Input side (Pulse input type) Function Description Common terminal for the input signal power supply.
Process data of Unit status module 28 6. RecordData 29 6.1. User specific RecordData 29 7. LED Indication and Alarm 30 7.1. LED Indication 30 7.2. Alarm 32 8. Specification 33 8.1. Dimensions 33 8.2. Specifications 34 9. Accessories 35 10.
Tightening torque: 28 to 30Nm Note 2) If the amount of drainage flowing into the heavy duty auto drain is small, open the bleed valve gradually to adjust so that the drainage can flow into the auto drain smoothly. 10.4 Maintenance 1) Check the auto drain condition at least once a day.
AC100V 50/60Hz 2.4/2.5 2.4/2.5 2.4/2.5 2.4/2.5 2.4/2.5 3.0/3.1 5.7/5.7 4.3/4.6 (2) A AC200V 50/60Hz 1.2/1.3 1.2/1.3 1.2/1.3 1.5/1.5 3.4/3.0 3.4/3.1 (2) W AC100V,AC200V 50/60Hz 180/202 180/202 180/202 180/202 180/202 208/236 385/440 420/480 (3) AC100V 10A AC200V 5A 10A R134a(HFC) AC100V/200V g 705 1155 1505 1805 2005 2505 2605 35010 Rc3/8 Rc1/2 Rc3/4 Rc1 10mm 1 2 kg 16 17 18 22 23 27 28
Tightening torque: 28 to 30Nm 2) Screw-in an elbow union (size: 17mm) to the drain outlet port and mount the drain tube. 3) Connect the two wires from the auto-drain to the two wires from the product. Drip proof connectors are used, which can be connected by hand. Ensure they are firmly connected.
Tightening torque: 28 to 30Nm 2) Screw-in an elbow union (size: 17mm) to the drain outlet port and mount the drain tube. 3) Connect the two wires from the auto-drain to the two wires from the product. Drip proof connectors are used, which can be connected by hand.
60Hz) AC200/200,22010%(4) AC230V (50Hz) AC23010%(4) AC100V (50/60Hz) 2.4/2.5 3.0/3.1 5.7/5.7 AC200V (50/60Hz) 1.2/1.3 1.5/1.5 3.4/3.0 (2) A AC230V (50Hz) 1.5 1.6 2.9 AC100V,AC200V (50/60Hz) 180/202 208/236 385/440 (2) W AC230V (50Hz) 210 220 400 AC100V 10 (3) A AC200VAC230V 5 R134a(HFC) AC100VAC200V 2005 2505 26010 g AC230V 2305 2705 29010 Rc3/8 Rc1/2 Rc3/4 mm 10 1 2 kg 23 27 28
Tightening torque: 28 to 30Nm Note 2) If the amount of drainage flowing into the heavy duty auto drain is small, open the bleed valve gradually to adjust so that the drainage can flow into the auto drain smoothly. 9.4 Maintenance Barrel nipple Elbow Hold the hexagonal part with a spanner when screwing the nipple.
Tightening torque: 28 to 30Nm Note 2) If the amount of drainage flowing into the heavy duty auto drain is small, open the bleed valve gradually to adjust so that the drainage can flow into the auto drain smoothly. 10.4 Maintenance 1) Check the auto drain condition at least once a day.
Tightening torque: 28 to 30Nm Note 2) If the amount of drainage flowing into the heavy duty auto drain is small, open the bleed valve gradually to adjust so that the drainage can flow into the auto drain smoothly. 9.4 Maintenance 1) Check the auto drain condition at least once a day.
AWD40 AWD30 AWD30 AWD20 AWD20 Spacer Y300(T)-A Y200(T)-A Y400(T)-A Y300(T)-A Y400(T)-A Y200(T)-A Compressed Air Fluid Range of operating conditions 0.3 to 0.85 0.3 to 0.85 0.3 to 1.0 0.3 to 1.0 Inlet air pressure MPa Inlet air temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Ambient temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Standard Performance 31 62 125 250 360 586 28
Differential pressure gauge GD40-2-01-X29 Y30(T)-A Y30(T)-A Y20(T)-A Y40(T)-A Spacer Y40(T)-A Y20(T)-A Fluid Compressed Air Range of operating conditions Inlet air pressure MPa 0.3 to 1.0 0.3 to 0.85 0.3 to 1.0 0.3 to 0.85 Inlet air temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Ambient temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Standard Performance 31 62 125 250 360 586 28
Recommended tightening torque (Unit: N m) Thread size 3/4 1 Torque 28 to 30 36 to 38 4) Before screwing-in an SMC fitting or S coupler, please refer to "Tightening the threaded portion of the connection thread" section of the Fitting & Tubing Precautions. 5) Do not apply torsion or bending moment other than the weight of the product itself.