SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-F02-L2-MA"

mA Internal voltage drop 0.8 V or less at load current of 10 mA (2 V or less at load current of 40 mA) 4 V or less Current leakage 100 A or less at 24 VDC 0.8 mA or less Indication light Operating position: The red LED lights up.

D-F6N D-F6P D-F6B Wiring type 3-wire type 2-wire type Output type NPN PNP Applicable load IC circuit / relay / PLC 24 VDC relay / PLC Power supply voltage 5/12/24 VDC (4.5 to 28 VDC) Current consumption 10 mA or less Load voltage 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at 10 mA load current (2 V or less at 40 mA load

40 mA or less 2.5 to 40 mA Internal voltage drop 0.8 V or less at load current of 10 mA (2 V or less at load current of 40 mA) 4 V or less Current leakage 100 A or less at 24 VDC 0.8 mA or less Indication light Operating position: The red LED lights up.

Model Wiring NPN transistor (open collector output) CEU5 50 mA or OUT less CEU5B Load Power CEU5-D COM (30VDC or less) CEU5B-D PNP transistor (open collector output) CEU5P (50 mA or less) OUT CEU5PB Load Power CEU5P-D COM (30VDC or less) CEU5PB-D 6-5.

. -25 NPN open collector output Max.30 V, 80 mA Residual voltage 1 V or less -65 PNP open collector output Max.80 mA Residual voltage 1 V or less -10No.PS-OMJ0004-E Pressure Setting Operation When the pressure exceeds the set value, the switch will be turned ON. When the pressure falls below the set value by amount of hysteresis or more, the switch will be turned OFF.

MHC MHT MHY MHY Max. tightening torque (Nm) Model Applicable bolts MHW2-20D MHW2-25D MHW2-32D MHW2-40D MHW2-50D 1.4 2.5 4.1 10.6 24.5 M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 MHW MHW -X MRHQ MA D723

180 Angular Type Air Gripper MHY2/MHW2 Series 10, 16, 20, 25 MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHY MHW MHW -X MRHQ MA D697 180 Angular Type Air Gripper MHY2/MHW2 Series Cam Type Rack & Pinion Type MHY2 Series/Cam Type Light and compact size in small bore sizes Over length L (mm) Gripping moment Weight (g) Bore size (mm) Model (Nm) L MHY2-10D 10 0.16 70 71 MHY2-16D 16 150 0.54 84 MHY2-20D

Current consumption [Power supply voltage] 1.5 V Power supply voltage for sensor 40 mA maximum (100 mA maximum for the total power supply current when 4 sensors are input.)

or less 170 mA or less 290 g 150 mA or less 250 g 1/8, 1/4 3/8 1/2 Heater type 3-digit, 7-segment LED 50 kPa to 0.75 MPa 50 kPa to 0.5 MPa 1.0 MPa 0 to 9 l NPN open collector Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V; 2 outputs Resistance Output specifications Note 5) Switch output PNP open collector Maximum

or less Switch Output NPN or PNP open collector OUT1: General-purposeOUT2: Valve control Maximum load current 80 mA Max. applied voltage DC26.4 V Residual voltage Max. 2 V (at 80 mA load current) Response time 2.5 ms or less (response times available for anti-chattering function: 20, 100, 500, 1000 or 2000 ms) Short circuit protection Provided Repeatability 0.2%F.S.1 digit Hysteresis Hysteresis

MA B Auto switch mounting heights D-A9V D-F9V D-F9WV (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL MA MA MA 20 25 25 27 25 27 27.5 29.5 A Approx.

MA B D-A9V D-F9V D-F9WV Auto switch mounting heights (mm) Bore size (mm) D-A9V D-F9V D-F9WV D-F9BAL SMC D-A90V SMC D-A90V MA MA MA 20 25 25.5 27.5 25.5 27.5 28 30 A Approx.

Connector pin numbers -18No.PS-OMS0007-H Internal circuit and wiring examples Z/ISE20(F)---Output specification -N NPN open collector 1 output Max. 28 V, 80 mA Residual voltage: 1 V or less -P PNP open collector 1 output Max. 80 mA Residual voltage: 1 V or less -19No.PS-OMS0007-H Outline of Settings [Measurement mode] Power is supplied.

External switch signal Current consumption: 5 mA or less Max. load current: 40 mA Max. load current: 40 mA Discharge signal Residual voltage: 1 V or less Residual voltage: 1 V or less Error signal Output signal (with load current of 40 mA) (with load current of 40 mA) Max. applied voltage: DC 28 V Maintenance signal Effective charge eliminating distance 20~500 mm 0~55oC Ambient temp.

Pressure Range: ISE70G (0 to 1 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)

Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)

Pressure Range: ISE77G (0 to 10 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE77G (0 to 10 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE75[H])

Pressure Range: ISE76G (0 to 5 MPa), Piping: 02 (Rc 1/4), Orifice: None, Unit Specification: M (SI Unit Only)