Size: No.2, Orifice: 10mm, Style: Normally Open, Option: For Other Fluid, Consult SMC -- Seal: EPDM, Body: Stainless Steel, Port Size: 04 [1/2 (15A)], Thread: NPTF, Bracket: -
Size: No.2, Orifice: 10mm, Style: Normally Open, Option: For Other Fluid, Consult SMC -- Seal: EPDM, Body: Stainless Steel, Port Size: 04 [1/2 (15A)], Thread: NPT, Bracket: -
Size: No.2, Orifice: 10mm, Style: Normally Open, Option: For Air and Water -- Seal: NBR, Body: Stainless Steel, Port Size: 04 [1/2 (15A)], Thread: NPT, Bracket: Bracket
Stations: 04 Stations, Port Size: ø1/4", Cable Length: 0 [Lead Wire (25 Cores) 0.6 m Lead Wire], Option 1: None, Option 2: Built-in Silencer, Direct Exhaust
Stations: 04 Stations, Port Size: ø1/4", Cable Length: 2 [Lead Wire (25 Cores) 3.0 m Lead Wire], Option 1: None, Option 2: Built-in Silencer, Direct Exhaust
Size: 3 (Body Ported), Pilot: 0 (Internal Pilot), Power Source, Command Signal: 2 (24V, 4~20mA), Port Size: 04 (1/2), Thread: N (NPT), Option: BN (Bracket, Silencer)
Body Class: 2 (ø4 Orifice), Fitting Type: V, Tube Size: 04 (ø4), Output Tube Size: None, Breathing Port Thread: Threaded, NPT1/8, Handle: 1 (90 Degree Turn Type)
Body Class: 4 (Class 4, Orifice ø12), Valve Type: 0 (Normally Closed), Port Size: 04 (1/2), Thread: N (NPT), Material: G (Body: PPS, Endplate: PPS, Diaphragm: NBR)
Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: 10 (One-touch Fitting ø10), VAC: 04 (Screw-in Rc 1/2), EXH: 12 (One-touch Fitting ø12), Accessories: S (w/Standard Bracket, w/Silencer)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Rated Flow Range: 102 (10 to 1000 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)
Function: 1 (2 Position Single), Body Option: 0 (Plug-in), Option: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: F (Plug-in), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: T (NPTF)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 04 (Sub-plate 1/2)
Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Centralized Lead Wire Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 04 (Sub-plate 1/2), Thread: F (G)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Release Valve Rated Voltage: 1 (100VAC 50/60HZ)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 10 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: T (NPTF), Control Unit: AP (Air Filter w/Auto Drain, Regulator, Air Release Valve,Pressure Switch), Release Valve Rated Voltage: 1 (100VAC 50/60HZ)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Extended Style), Port Specification: Side Ported, Port Size: 04 (1/2), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: A (Non-locking Push Extended Style), Port Specification: B (Bottom Ported), Port Size: 04 (1/2), Thread: T (NPTF)