SMC Corporation of America
Elite Part Number Search
Search Results "11-CDJ2B10-150-B"

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L3 (9 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 7 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N11 (ø3/8" One-touch Fitting, Straight, Inch)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L3 (9 Cores), Lead Wire Length: 3 (3m), Valve Stations: 3 Stations, P,E Port Entry: D (D Side, 2 to 10 Stations), SUP/EXH Block Assembly: S (Internal Pilot, Built-in Silencer), A,B Port Size: N9 (ø5/16" One-touch Fitting, Straight, Inch)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 8 Stations, P,E Port Entry: D (D Side, 2 to 10 Stations), SUP/EXH Block Assembly: S (Internal Pilot, Built-in Silencer), A,B Port Size: C10 (ø10 One-touch Fitting, Straight, Metric)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L3 (9 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 3 Stations, P,E Port Entry: D (D Side, 2 to 10 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N7 (ø1/4" One-touch Fitting, Straight, Inch)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L1 (34 Cores), Lead Wire Length: 1 (0.6m), Valve Stations: 2 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N9 (ø5/16" One-touch Fitting, Straight, Inch)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 4 Stations, P,E Port Entry: D (D Side, 2 to 10 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N7 (ø1/4" One-touch Fitting, Straight, Inch)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 3 (3m), Valve Stations: 3 Stations, P,E Port Entry: D (D Side, 2 to 10 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N11 (ø3/8" One-touch Fitting, Straight, Inch)

Model: 11 (Bottom Ported), Number of Cores - Lead Wire: L2 (17 Cores), Lead Wire Length: 2 (1.5m), Valve Stations: 8 Stations, P,E Port Entry: U (U Side, 2 to 10 Stations), SUP/EXH Block Assembly: Internal Pilot, A,B Port Size: N11 (ø3/8" One-touch Fitting, Straight, Inch), Mounting: AA (Direct Mounting, Name Plate w/Station Number)

Model: 12 (Top Ported), Number of Cores - Lead Wire: L1 (34 Cores), Lead Wire Length: 3 (3m), Valve Stations: 11 Stations, P,E Port Entry: B (Both Sides, 2 to 24 Stations)

Stations: 11 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: B (Bottom Ported Rc1/4), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: None, Option 2: W (IP65 Protection Compatible)

Stations: 11 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: B (Bottom Ported Rc1/4), Thread: T (NPTF), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting)

Stations: 11 Stations (Note: 2 Stations are Required for Terminal Box Mounting), Port Size: B (Bottom Ported Rc1/4), Thread: Rc (PT), Kit Name: T (Terminal Box), Box Mounting Position: 0 (U Side Mounting), Control Unit: None, Release Valve Rated Voltage: w/o Air Release Valve, Option 1: CDN (Exhaust cleaner: D side mounting with name plate)

Stations: 11 Stations, Port Size: C6 (ø6 One-touch Fitting), Cable Length: 2 (3.0m Cable 25 Pin), Option 1: B (Back Pressure Check Valve for All Stations)

Variations include energized open (N.C) and energized closed (N.O) valves, class B or class H coils, brass, BC6, or stainless steel body materials and NBR, FPM, EPR, PTFE seal materials., VALVE, MEDIA (N.C), VALVE, VXP/VXR/VXF 2-WAY MEDIA VALVE, 1A, VXP/VXR/VXF, 11 lb

Caution 1.If the back pressure or back flow are generated, Foundation B olt it may damage an element. 2.Failure to discharge the drain will allow the accumulated drain to flow over to the outlet side. -8- FGX-OM-P003-A 5.Maintenance 1) Daily maintenance 1.Open the drain valve and discharge the drain at least once a day.

B: Limited warranty and Disclaimer and measurement laws are added. C: Modified errors in text. [July 2016] D: Contents revised in several places.

Air leakage from output [2(B),4(A)] port and exhaust [5 (EA),3(EB)] port. because foreign matter get caught in the main valve. Air leakage 2) Sealing failure of the actuator Refer to the operation manual of the actuator for details. (cylinder) If the countermeasures above are not effective, there may be a trouble with the valve. Stop using the valve immediately.

0.02 35 or less1250/20Ball screw + Belt (Motor parallel)Sliding bearing (LEYGlM), Ball bushing bearing (LEYGlL)41 to 104F (5 to 40C)90 RH or less (No condenstation)l4236Servo motor (24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 (0.15) (Screw mounting), 0.37 (0.17) (DIN rail mounting)Non-magnetizing operation type17.5524 VDC ?10%

0.02 35 or less1250/20Ball screw + Belt (Motor parallel)Sliding bearing (LEYGlM), Ball bushing bearing (LEYGlL)41 to 104F (5 to 40C)90 RH or less (No condenstation)l4236Servo motor (24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 (0.15) (Screw mounting), 0.37 (0.17) (DIN rail mounting)Non-magnetizing operation type17.5524 VDC ?10%

0.02 35 or less1250/20Ball screw + Belt (Motor parallel)Sliding bearing (LEYGlM), Ball bushing bearing (LEYGlL)41 to 104F (5 to 40C)90 RH or less (No condenstation)l4236Servo motor (24 VDC)Incremental A/B (800 pulse/rotation)/Z phase24 VDC ?10%864 (Horizontal)/12 (Vertical)960.33 (0.15) (Screw mounting), 0.37 (0.17) (DIN rail mounting)Non-magnetizing operation type17.5524 VDC ?10%