Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only
Nozzle for One-touch fittings; Tube materials: KN-Q*A, KNA: PBT; KN-Q, KNAG: SUS; Multiple nozzle diameters: KN-Q(*A) only; Compatible fitting series: KN-Q*A, KNA: KQ2, KC, KB, KP, KX, KS, KQB2, KQG2; KN-Q, KNAG: KQB2, KQG2; Meets OSHA 1910.242(B) standard for deadhead pressure [KNA(G)] only
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Volume of Release Air Tank: V2: L [3.2 cm³ (See Catalog for Calculation)], Stations: 4 Stations, Voltage: 12 VDC, Electrical Entry: L Plug Connector, Blanking Plate: without Blanking Plate, CE-compliant: CE Compliant
Symbol: Body Ported, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: None, Bracket: Bracket, Lead Wire Length: Grommet, 600mm; Light/Surge: No, CE Compliant: CE Compliant
Symbol: Body Ported, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: None, Bracket: Bracket, Lead Wire Length: Grommet, 600mm; Light/Surge: No, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.O., Port 3 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 3 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Power-saving Circuit, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 3 Port, Universal, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 2 Port, N.C., Port 1 IN, Port 2 OUT, Tubing Type, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 3 Port, Universal, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: FKM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PVDF, 1/4-28UNF, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PFA; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: PFA, M6, Option: Manual Override, Lead Wire Length: 600mm, CE Compliant: CE Compliant
Symbol: Body Ported, 3 Port, Universal, Tubing Type, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Bracket, Lead Wire Length: 600mm, CE Compliant: CE Compliant