Usable stroke by buckling strength Usablestroke by Mounting style buckling strength (cm) Pressure Symbol and sketch (MPa) Symbol of bracket Rod side Frang e F Head side flange 103 92 113 Foot: 79 70 86 L G 66 58 72 45 38 47 33 27 34 26 22 27 96 83 106 Center Clevis trunnion 71 61 76 CD T 59 50 62 135 119 147 101 89 111 84 74 91 Rod side Frang e F Head side flange 301
(mm) 6 10 Piston speed (m/s) 0.05 to 0.5 Allowable kinetic energy 0.012 0.035 (J) Figure 4-1 4-2. Allowable lateral load of the plate Caution If this cylinder has an eccentric distance (L) from the plate (the rod end), the load weight (W) should be not more than the values shown in the graph below.
(Tightening torque: 0.6 Nm) -40No.EX-OME0015-F Specification Specifications General specifications Item Specifications Ambient temperature 0 to +55 oC (when 8 valves are ON at the same time) 0 to +50 oC (when 16 valves are ON at the same time) Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage 20 to +60 oC Withstand voltage 1000 VAC applied for 1 minute Insulation
S: Effective sectional area (mm Air temperature() -20 -10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 SYJ500*-OMJ0001-A -- TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.
S: Effective sectional area (mm Air temperature() -20 -10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 No.SYJ700*-OMK0001-A -6- TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.
Failure of the power supply for the solenoid valve Check supply voltage of the solenoid valve power supply. -27No.EX-OME0014-F Specification Specifications General specification Item Specification Operating ambient temp. -10 to +50 oC Operating ambient humidity 35 to 85%RH (No dew condensation) Storage ambient temp. -20 to +60 oC Withstand voltage 500 VAC for 1 min.
S Slave station Collective description of stations other than the master station. -8No.EX-OMO0007-E Installation and Cabling General Instructions on installation Applicable valve series The EX180 series SI unit can be mounted on the following valve manifolds.
S. Set dat a Pressure 100% 75% 50% 25% 0% 0 256 512 767 1023 Input data 7 - Communication protocol The character-code used to communicate is ASCII. Please put space between the command and the numerical value. Setting of output pressure Command Content SET nn Set required setting data of output pressure (01023) Note) nn is limited to integral values from 0 to 1023.
Grommet, L/M Plug Connector DIN Terminal For AC Terminal Terminal Terminal Terminal (5) (1) There is no S type because the generation of surge voltage is prevented by a rectifier. Surge voltage suppressor of varistor has residual voltage corresponding to the protective element and rated voltage; therefore, protect the controller side from the surge.
S: Effective sectional area (mm Air temperature() -20 -10 0 10 30 40 50 60 Correction coefficient 1.08 1.06 1.04 1.02 0.98 0.97 0.95 0.94 SYJ5000-OMJ0001-A -6- TROUBLESHOOTING Should any trouble be found during operation, trace the source of the trouble in the following order and take corrective action.
SQ1000 SQ2000 Built-in silencer direct exhaust (-S) SSQ1000-SE SSQ2000-SE * Part numbers above are for a set of ten elements. 10 No.SQ1000V-OMQ0002-B 11 No.SQ1000V-OMQ0002-B 12 No.SQ1000V-OMQ0002-B 13 No.SQ1000V-OMQ0002-B 14 No.SQ1000V-OMQ0002-B 15 No.SQ1000V-OMQ0002-B 16 No.SQ1000V-OMQ0002-B 17 No.SQ1000V-OMQ0002-B 18 No.SQ1000V-OMQ0002-B 19 No.SQ1000V-OMQ0002-B 20 No.SQ1000V-OMQ0002-B 21
4" 6 6, 8 1/4" 5/16" 3/8" Tubing O.D. 3/16" 1/4" 1/4" 5/16" 3/8" 3/8" Inch size Flow rate l/min (ANR) Controlled flow (Free flow) 500 600 700 1200 1300 175 295 350 75 {N R/min} Effective area (mm2) 7.6 9.1 10.7 18.3 19.8 2.7 4.5 1.1 5.3 Note) Flow rate values are measured at 0.5 MPa and 20C. 15-9-14 2 Dual Speed Controller with One-touch Fitting Series ASD How to Order ASD 3 30F 01 06 S
How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.
Applicable cylinder bore size (mm) AS121-M5 Model Port size 4 6 8 10 12 M5 x 0.8 6, 10, 16, 20 Construction 1 8 AS221-01 R 20, 25, 32 1 4 AS221-02 R 20, 25, 32, 40 3 8 AS321-03 R 40, 50, 63 1 2 AS421-04 R 63, 80, 100 Note) marking is electroless nickel plated, provided as standard.
Working Stroke during Normal Operation Movement of the cylinder Movement of the cylinder Time Time 15-15-2 3 Safety Speed Control Valve Series ASS Cylinder Extension Prevention Primary Speed Flow Characteristics ASS100/ASS110 Meter-out Control Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Effective area (mm2) Effective area (mm2) Effective area (mm2) Effective area (mm2) Primary speed (mm/s)
Metric 4, 6 6 8, 10 6, 8 1/4" 5/16" 3/8" 1/8" 5/32" 3/16" 1/4" Tube O.D. 1/4" 5/16" 3/8" 3/8" Inch 500 600 700 1200 1300 175 295 350 75 Air flow (l/min(ANR)) Controlled (free)/Flow 7.6 9.1 10.7 18.3 19.8 1.1 2.7 4.5 Eff. area (mm2) 5.3 Note 1) Max. operating pressure: 0.5MPa, Temperature: 20C 4.1-13 Dual Speed Controller with One-touch Fittings Series ASD How to Order ASD 3 30F 01 06 S
Size: 5 (50), Body Material: S (Stainless Steel), Seal Material: F (FKM), Port Size: 06 (3/4), Thread Type: N (NPT), Rated Voltage: 3 [120 (110) VAC], Electrical Entry: CS (Conduit, w/Surge Voltage Suppressor)
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm): 5 to 100 , Mountings include: Through hole (standard), threaded, clevis, rod flange, head flange, and foot
Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes (mm): 12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm): 5 to 100 , Mountings include: Through hole (standard), threaded, clevis, rod flange, head flange, and foot
Table Accuracy: Basic, Size: 50, Max.