SMC Corporation of America
Elite Part Number Search
Search Results "LEFG16-S-50"

Material: S (Vessel: Stainless Steel; Seal: NBR), Number of Elements: 5 pcs. (FGF*5), Element Size: B (ø190 x â„“770), Port Size: 60 (6B JIS10kFF, FGF*5), Nominal Filtration Accuracy: 50 μm

Port size: 1/2, 3/4, 1, Applicable thread type: Rc, G, NPT, NPTF, Type of actuation: Normally open/Normally closed (Changeable), Operating pressure range: 0.2 to 0.9 MPa, Impact/Vibration resistance: 150/50 m/s, VALVE AIR PILOT, VALVE, VG/VGA VALVE, LA, VG BODY PT >3/4, 2.10442 lb

Port size: 1/2, 3/4, 1, Applicable thread type: Rc, G, NPT, NPTF, Type of actuation: Normally open/Normally closed (Changeable), Operating pressure range: 0.2 to 0.9 MPa, Impact/Vibration resistance: 150/50 m/s, VALVE, AIR PILOT, VALVE, VG/VGA VALVE, JA, VG BODY PT 1/2, 2.23802 lb

CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *, Most options are auto switch capable, Available strokes: 25mm to 1500mm depending on bore size, 7 mounting options, CYL AIR 20MM, DBL ACT, AUTO-S, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, HE, 20MM CG DBL-ACT AUTO-SW, 1.09876 lb

A dedicated solenoid valve is not required for unlocking, thus reducing the initial costs and replacement of the existing equipment.Bore size (mm): 32-63, Stroke (mm): 50-150, Can be locked at any position within the entire stroke, Selection of retraction locking & extension locking is possible, Piping not required for unlocking, CYL, CLAMP W/LCK, A/S MTG ROD, CLAMP CYLINDER W/LOCK CLKQ

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, clevis, rod flange, head flange, and foot

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63, 80, 100 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange, Auto switch capable,

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63, 80, 100 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange, Auto switch capable,

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63, 80, 100 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange, Auto switch capable,

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, clevis, rod flange, head flange, and foot

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange , Auto switch capable

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange , Auto switch capable

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange , Auto switch capable

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange , Auto switch capable

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63, 80, 100 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, foot, and rod flange, Auto switch capable,

Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, non-rotating compact cylinder , Bore sizes (mm):  12, 16, 20, 25, 32, 40, 50, 63 , Standard stroke range (mm):  5 to 100 , Mountings include: Through hole (standard), threaded, clevis, rod flange, head flange, and foot

S SI unit Abbreviation of serial interface unit. A unit connected to a PLC to communicate input and output data. T Topology Connection configuration of the network -10No.EX-OMX1001 Installation and Wiring Installation Connect valve manifold to the SI unit.

Switch OFF Time [s] : The Product outputs will continue operating during setting. 1. Press the button in measurement mode to display the set values. [P_1] or [n_1] and the set value are displayed in turn. : [LLL] is displayed during measurement mode when the sensor is not connected.

[Inrush] Rated voltage [Holding] 1 2 35% (SX090) 42% (SX9 ) of rated voltage 0 V 100 10 ms T1 (ON) (2 s or more) T2 (OFF) Energized condition -8- Dimensions 2-port SX91/Normally closed SX92/Universal 10 Base hole dimension 4.5 0.05 2 x M2 x 0.4 Thread depth: 6 or more 9.8 0.3 7.4 38.1 (Lead wire AWG#26) 300 5 5 10 3.4 +0.05 0 2 x 3 (Port hole dimension) (4.5 0.05) 10.3 8.4 8.3 8.9 C0.2 or

Consecutive 8 bits of the message are added, and the result without carry (overflow) is converted to 2's complement.