Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: None, Auto Drain: D (N.O. Auto Drain)
Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: B (Bracket)
Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: None, Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: Standard, Air Pressure: Standard, Drain Guide: None, IN-OUT Direction: Standard, Pressure Switch 125VAC, 30VDC: None, Element Service Indicator: T (Yes)
Compressor Output 15HP, (11kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: None, Auto Drain: D (N.O. Auto Drain)
Compressor Output 15HP, (11kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: None, Auto Drain: D (N.O. Auto Drain), Rubber Material: Standard, Air Pressure: H (Medium Air Pressure, 1.6MPa)
Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: B (Bracket), Auto Drain: D (N.O.
Compressor Output 30HP, (22kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: None, Auto Drain: D (N.O.
Compressor Output 15HP, (11kW)], Thread: F [G (Conforms to ISO1179-1)], Port Size: 06 (3/4), Accessory: B (Bracket), Auto Drain: D (N.O. Auto Drain), Rubber Material: Standard, Air Pressure: H (Medium Air Pressure, 1.6MPa)
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 1 (Meter-in, Light Blue Handle), Port Size: U03 (Uni 3/8), Applicable Tube O.D.: 06 (ø6)
Body Size: 3 (3/8), Type: 2 (Elbow), Control Type: 0 (Meter-out, Gray Handle), Port Size: U02 (Uni 1/4), Applicable Tube O.D.: 06 (ø6)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 3 (3 Position Closed Center), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 4 (3 Position Exhaust Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 1 (2 Position, Single), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: F (Plug-in), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)
Function: 2 (2 Position, Double), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4)
Function: 5 (3 Position Pressure Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: None, Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 06 (3/4), Thread: N (NPT)
Function: 3 (3 Position Closed Center), Model: 1 (Non Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: C (Locking Lever Style), Port Specification: Side Ported, Port Size: 06 (3/4)