Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve: None; Stop Valve: None, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve: None; Stop Valve: None, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; w/Stop Valve, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; Stop Valve: None, Supply/Return Port Size: 3/8, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: -, Return Unit Flow Switch Unit Specifications: -
Valve; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F
Valve; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F
Valve; Stop Valve: None, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: NPN; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Flow Switch Unit Specifications: Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F
Valve; Stop Valve: None, Return Port Size: 3/8, Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/o Lead Wire and M8 Connector, Flow Switch Unit Specifications: Integrated Display: L/min; Accumulated Flow: L; Temp.: °F
Valve; w/Stop Valve, Return Port Size: 1/2, Flow Switch Output Specifications: Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes, Lead Wire: w/o Lead Wire and M8 Connector, Flow Switch Unit Specifications: Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F
-L1) Width at closing (mm) (L1) Width at opening (mm) (L2) Weight (g) Model 11221122112211221122112211221122112211221122112211221122112211221122112260 72 94 112 84 126 92 134 172 114 186 340 405 485 660 870 20 40 60 30 60 MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 10 40 60 L1 16 40 L2 146 98 158 178 116 226 138 238 278 166 1010 1175 1645 1840 1850 80 40 80 100 50 MHL2-16D2 MHL2-20D MHL2
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 2 [With output (Alarm output x 2 + analog output (4 to 20 mA DC))], Accessories: D (Fork Lever-type Fitting S)
Type: 101 (Smart Rotary Type), Pressure Gauge: 3 (1.0 MPa), Specifications: 2 [With output (Alarm output x 2 + analog output (4 to 20 mA DC))], Accessories: C (Fork Lever-type Fitting M)
Input Specification: 1 (Current Input), Output Specification: 4 (2 PNP Outputs + 4 to 20 mA Output), Unit Specification: Unit Switching Function, Connector: None, Option: None, Sensor Connector: None, Instruction Manual: N (None)
Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT)