Symbol: Body Ported, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: Grommet, 1000mm; Light/Surge: No, CE Compliant: -
: Electromagnetic Type, Switching Type: Normally Closed, Body Material: Resin, Connection Type: M, Plumbing Thread Nominal: M5, Tube Diameter: -, Operating Temperature Range(°C): 0~50, Driving Type: Linear Motion Type, Orifice Diameter(Ø): 1.5, Insulation Class: B, Pipe opening type (details): Body Ported Type, Voltage: 24 V DC, Option: None, Power Consumption(W): Inrush: 2.5 / Holding: 1,
Pressure Setting 1. Internal circuit and example of wiring Caution Caution Circuit Vcc D1 1. Pressure setting While pressing q SET, turn pressure-setting slotted screw e P.SET (counterclockwise to decrease) and watch the LCD. When the LCD shows the correct figure, stop turning P.SET and release the SET button. Set pressure is displayed on the pressure display panel r LCD.
Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez?
Click here for details Port size (Rc) 06 08 10 12 16 20 24 3/4 1 1 1/4 1 1/2 2 2 1/2 3 Differential pressure indication Nominal filtration 0 4 5 005 010 020 074 105 5 m 10 m 20 m 74 m 105 m None Differential pressure indicator Differential pressure indication switch Note) Note) N.C. and N.O. common Note) The paper elements for water-glycol or emulsion is 10 m only.
Nil FKM 1349-80*1 N1 EPDM 2101-80*1 P1 Barrel Perfluoro 70W Q1 Kalrez 4079 R1 Chemraz SS592 R2 SS630 R3 SSE38 S1 VMQ 1232-70*1 T1 FKM for Plasma 3310-75*1 *1 Values at normal temperature, excluding gas permeation *2 Refer to Construction on page 5 for changed part. Number corresponds with the parts number on the construction drawing.
How to Order 100 IP200 Applicable stroke 25 to 300 mm * Manufacture of strokes in 1 mm increments is possible. Specifications (No load) Note 1) Replacement Parts Supply pressure 0.3 to 0.7 MPa Input pressure 0.02 to 0.1 MPa Part no.
Rotary Actuator Vane Type CRB2 Series Size: 10, 15, 20, 30, 40 RoHS How to Order B S E 20 180 S Z CRB2 u Z L M9B CDRB2 B W 20 180 S With auto switch q r e !1 i o !
1 Output 3-Screen Display High-Precision Digital Pressure Switch RoHS IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
1 Output RoHS 3-Screen Display High-Precision Digital Pressure Switch IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
Example) AW30-03C-2R-X2622A y t r e w q Stainless steel 316 specification Symbol Description K q Body size 30 40 IP K w Thread type Nil Rc N NPT F G + IW 02 1/4 03 3/8 04 1/2 06 3/4 + 1301 K e Port size AW AW IL1 K r Option i a Float type auto drain Nil Without option C Note 1) Float type auto drain (N.C.
FH150 Series How to Order 0 1 0 02 P 005 FH150 Made to Order Hydraulic filter Nil X0 None (Standard) Micromesh element equipped Port size (Rc) Note) Click here for details 02 03 04 1/4 3/8 1/2 Bracket Nil None With bracket B Differential pressure indication Nominal filtration None Differential pressure indicator Differential pressure indication switch Note) 0 4 5 005 010 020 5 m 10 m 20 m
JSY3000 SY30V-25AS JSY5000 SY50V-25A Nil Standard a-side pilot valve T With power saving circuit (Made to Order) Plug-in Pilot cover x 1 + B tight at head screw x 1 Rated voltage Pilot cover w 5 24 VDC 1 Socket q Caution w 1. The coil specication and voltage (including light/ surge voltage suppressor) cannot be changed by changing the pilot valve assembly. 2.
How to Order 100 IP200 Applicable stroke 25 to 300 mm * Manufacture of strokes in 1 mm increments is possible. Specications (No load) Note 1) Replacement Parts Supply pressure 0.3 to 0.7 MPa Input pressure 0.02 to 0.1 MPa Part no.
Add L to the end of the part number when 3 m is desired, M when 1 m, and Z when 5 m. Example) -M9NL Symbol Nil A B C Mounting position Valve open/closed Valve open Valve closed Quantity Without auto switch 2 pcs. 1 pc. 1 pc.
Add to Cart SMC SY3000-GS-1 gasket, SY3000 SOL/VALVE, RUBBER SEAL*** $3.59 + Add to Quote Add To Cart Add to Cart, 0.12503 lb
Rotary Gripper Series MRHQ How to Order Lead wire length 0.5 m 3 m 5 m Nil L Z MRH 10 90 M9NV Q S M9N D Number of auto switches Rotary gripper Type of auto switch for detecting rotation Nil Without auto switch(Built-in magnet) 2 pcs. 1 pc.
Series: 1 (VQZ1000), Composite Symbol: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: w/o Sub-plate, Q: Q (CE Marked)
Series: 1 (VQZ1000), Composite Symbol: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: G (Grommet Lead Wire 0.3m), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: w/o Sub-plate, Q: Q (CE Marked)