SMC Corporation of America
Elite Part Number Search
Search Results "LQ3E4A-S-3"

.); 250 psig (1.7 MPa)], Material: S (316L SS Secondary Remelt), Surface Finish: M [10 μin. (0.25 μm)], Ports: 3PWE [3 Ports (1-In; 2-Out; 3-In)], Connection 1: TW6 (3/8 Inch Tube Weld), Connection 2: TW6 (3/8 Inch Tube Weld), Connection 3: TW6 (3/8 Inch Tube Weld), Connection 4: No Port, Face to Face Dimensions: 2.12 Inch (53.8 mm) Standard for TW4; or Not Applicable to All Other Connections

Model: 625 (1/4 Turn Lever Knob), Material: S (316L SS Secondary Remelt), Surface Finish: M [10 μin. (0.25 μm)], Ports: 3PWD [3 Ports (1-In; 2-Out; 3-In)], Connection 1: TW6 (3/8 Inch Tube Weld), Connection 2: TW6 (3/8 Inch Tube Weld), Connection 3: TW6 (3/8 Inch Tube Weld), Connection 4: No Port, Face to Face Dimensions: 2.12 Inch (53.8 mm) Standard for TW4; or Not Applicable to All Other

Model: 650 (1/4 Turn Round knob with Open/Close Indication Window), Material: S (316L SS Secondary Remelt), Surface Finish: M [10 μin. (0.25 μm)], Ports: 3PWD [3 Ports (1-In; 2-Out; 3-In)], Connection 1: TW6 (3/8 Inch Tube Weld), Connection 2: TW6 (3/8 Inch Tube Weld), Connection 3: TW6 (3/8 Inch Tube Weld), Connection 4: No Port, Face to Face Dimension: 2.12 Inch (53.8 mm) Standard for

3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?

3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?

s [3 cP] or less) Note 1)Karman vortex30 to 250 L/min0 to 70oC (with no freezing and condensation)p3% F.S.p2% F.S.p5% F.S. (25oC reference)0 to 1 MPa Note 2)1 MPa45 kPa or less at the maximum flow1 sVoltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCFor power supply status, flow rate indicator (Blinking speed changes

(Inert gas)1.5 MPa1.0 MPa0 to 50C (With no condensation)0.03 s or less3% F.S.3% F.S.0.5% F.S.

s [3 cP] or less) Note 1)Karman vortex30 to 250 L/min0 to 70oC (with no freezing and condensation)p3% F.S.p2% F.S.p5% F.S. (25oC reference)0 to 1 MPa Note 2)1 MPa45 kPa or less at the maximum flow1 sVoltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCFor power supply status, flow rate indicator (Blinking speed changes

3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?

3% F.S. or less?5% F.S. or less (0 to 50C, based on 25C)70 mA or less700 g1/2, 3/4Karman vortex3-digit, 7-segment LEDl/min, gal(US)/minl, gal(US)0 to 1 MPa1.5 MPa0 to 999999 lOperating: 0 to 50C, Stored: ?

(de-energized)490 m/s2 in X, Y, Z directions 3 times each1000 Vp-p, Pulse width 1 ?s, Rise time 1 ns

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g

s [3 cP] or less) Note 1)Karman vortex10 to 100 L/min0 to 70oC (with no freezing and condensation)p3% F.S.p2% F.S.p5% F.S. (25oC reference)0 to 1 MPa Note 2)1 MPa45 kPa or less at the maximum flow1 sVoltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCFor power supply status, flow rate indicator (Blinking speed

(No load)ResistanceWeight Note 3)Port size (Rc, NPT, G)PF2A521Air, NitrogenHeater type20 to 200 l/min?

(Inert gas)1.5 MPa1.0 MPa0 to 50C (With no condensation)0.03 s or less3% F.S.3% F.S.0.5% F.S.

4 , 3 8Air (Inert gas)1.5 MPa1.0 MPa0 to 50C (With no condensation)0.03 s or less3% F.S.3% F.S.0.5% F.S.3% F.S. or lessNot required (Use turbine oil Class 1, ISO VG32, if lubricated.)0.9

(kg)Pressure typeVEP31211 4 , 3 8Air (Inert gas)1.5 MPa1.0 MPa0 to 50C (With no condensation)0.03 s or less3% F.S.3% F.S.0.5% F.S.3% F.S. or lessNot required (Use turbine oil Class 1, ISO VG32, if lubricated.)0.9

s [3 cP] or less) Note 1)Karman vortex30 to 250 L/min0 to 70oC (with no freezing and condensation)p3% F.S.p2% F.S.p5% F.S. (25oC reference)0 to 1 MPa Note 2)1 MPa45 kPa or less at the maximum flow1 sVoltage output: 1 to 5 V Output impedance: 1 k7Output current: 4 to 20 mA Max. load impedance: 300 7 for 12 VDC, 600 7 for 24 VDCFor power supply status, flow rate indicator (Blinking speed changes