Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb
Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb
Service life (based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez« , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, CHEMICAL VALVE, 2 PORT, B07, 0.034 lb
Connector pin numbers (lead wire) Sub display Displays the accumulated flow, set value, and peak/ bottom value when in measurement mode. 2 1 button (UP) Selects the mode and the display shown on the Sub display, or increases the switch point. 1: Selected items of (1) to (3) become valid after pressing the S button. 2: After enabling the setting by pressing the S button, it is possible to
The tightening torque must be 1 to 1.2 Nm. 2 4 Safety Instructions 4 OUT1 (C/Q) How to reset the product after a power cut or when the power has been unexpectedly removed The settings of the product are retained from before the power cut or de-energizing.
[F90] [ ALL] Setting of all functions [ oFF] OFF 4 C/Q Black Communication data (IO-Link)/Switch output 1 (SIO) [F98] [ tESt] OUT1 output test mode [ n] Normal output : When using the lead wire with M8 connector included with the PF3W7 series.
8 NPT 1/8 None With seal Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa Nil S X202 Lead wire length 3 m Regulating pressure range 0.1 to 0.6 MPa X215 16-9-1 2 Series IS1000 Construction 5 500 50 20 t u 0.1 0.2 y 0.3 0.4 i 58.5 MPa q Component Parts !
Bracket (Option) AV R 1/8, 1/4 Dedicated mounting screw AU 22 14 (Hex. width across flats) (M4 x 0.7) M5 x 0.8 38 AF 2 26 2-4.5 600 8 AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (Lead wire length) 19 3 25 IR 5 9 8 5 VEX 36 1 3 22 22 AMR 3.2 ITV IC M5 type
Pressure Setting 1. Internal circuit and example of wiring Caution Caution Circuit Vcc D1 1. Pressure setting While pressing q SET, turn pressure-setting slotted screw e P.SET (counterclockwise to decrease) and watch the LCD. When the LCD shows the correct figure, stop turning P.SET and release the SET button. Set pressure is displayed on the pressure display panel r LCD.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: B (Plate: PEEK; Diaphragm: FKM), Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: 10 (Grommet, 1000mm; Light/Surge: No)
Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: 10 (Grommet, 1000mm; Light/Surge: No)
Symbol: 11 (Body Ported), Voltage: 5 (24 VDC), Wetted Part Material: A (Plate: PEEK; Diaphragm: EPDM), Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: 10 (Grommet, 1000mm; Light/Surge: No)
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 12 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: EPDM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, 2 Port, N.C., M5 Thread, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Sub-plate Material, Port Size: w/o Sub-plate, Option: Bracket + Manual Override, Lead Wire Length: -
Symbol: Body Ported, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: FKM, Reverse Mounting Prevention Pin: None, Bracket: None, Lead Wire Length: Grommet, 1000mm; Light/Surge: No, CE Compliant: -