Val: 1 to 65000 4 Valve ON/OFF counter (Counter) 8 Disable Does not generate an error. 1: This function is valid only when Hold/Clear priority of the system parameter is set to Handheld. 2: Some PLC does not support an idle mode. 3: The count is memorized every 30 seconds per channel.
M3 x 30 screw for connection to the valve manifold. Seal cap 1 pc. seal cap for unused fieldbus interface connector (BUS OUT). 1: Refer to page 28 for applicable connector cables. 2: Refer to page 16 for the LED Indication and Settings. -9No.EX-OMP0005-I Installation and Wiring Installation Connect valve manifold to the SI unit.
Tubing size Tensile force of tubing (N) 3.2, 1/8'' 5 4, 5/32'' 8 6, 1/4'' 12 8, 5/16'' 20 10, 3/8'' 30 12, 1/2'' 35 16 50 7 - Caution (1) Chamfer dimension for female thread of the connection thread Confirming to ISO 16030 (air pressure fluid dynamics connection ports and stud ends), the chamfer dimensions shown below are recommended.
Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction.Use caution regarding the air supply.. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit. 2. Separate the SI unit to valve manifold. 3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass through a block by the tie-rod. 4.
Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. When instructions are given in the Specific Product Precautions, follow these specifications. 4. Closed center types For closed center type, check the piping to prevent air leakage from the piping between the valve and the cylinder. 5.
Inclination from the vertical line should be less than 5. 3) Install one-touch fitting (width across flats: 17) to drain port (width across flats: 30) and the drain tube. 4) Connect the 2 electric cables coming out from the auto drain with the two electric cables from the dryer unit. Insert the drip-proof connector to the deepest part.
Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the mounting screws and brackets may become loose. The product body is made of resin.
ZB-OM00201-B Contents Safety Instructions 2 Model Indication and How to Order 10 Names of parts of product 16 Mounting and Installation 18 Air Supply 20 Supply Pressure 21 Piping 21 Handling of the V Port Assembly 22 Solenoid Valve 26 Construction 30 Maintenance 31 Replacement Procedure for Filter Element 36 Replacement Procedure for Silencer 37 Replacement Procedure for Solenoid Valve (Supply
EX120/121/122/124U/124D-SCS1 EX120/121/122/124U/124D-SCS2 Applicable system CompoBus/S Communication specifications Node address setting range 0 to 14 0 to 15 Communication speed 750 kbps Cable length Cable type Main cable length Branch cable length Total branch cable length When using VCTF cables 100 m or less 3 m or less 50 m or less When using special flat ribbon cable 30 m or less 3
Refer to page 30 for detail. -21No.EX-OMI0032-G HW/SW mode setting (Switch No.10) The setting is as follows. The setting at shipment is turned OFF, set to HW mode. Mode No.10 Function HW OFF Set Address with No.1 to 7 (SW1). Addresses are set by network. Class 2 master is required for the setting via network. It is set at 126 when delivery. SW ON : No.1 to 7 (SW1) are ignored.
Outer dimensions and descriptions of each part part 2) Descriptions of each part HAA7 to 22 24 12 15 5 HAA37 11 22 23 13 7 9 10 4 21 28 29 30 1 13 19 8 25 27 17 3 14 Components of aircooled aftercooler and descriptions No.
. -4- 1.1.2 Specification Model LEJS100T9H LEJS100T9A LEJS100T9B Stroke [mm] *1 200300400500600800100012001500 3000(mm/s2) 60 150 400 5000(mm/s2) 43 93 150 Horizontal 9800(mm/s2) 22 36 Work load [kg] *2 3000(mm/s2) 14 29 80 5000(mm/s2) 12 29 30 Vertical 9800(mm/s2) 8 9 Actuatr specifications Electric specifications Lock unit to 500 2300 1250 500 Max. speed *3 501 to 1000 1600 800 320 [mm/
Long spacer -20 -30 -40 -70 -10 -50 -60 -80 0 0 to 16 32 to 48 16 to 32 MY140 Without spacer Short spacer Long spacer 0 to 20 20 to 40 40 to 60 MY150 Short spacer Long spacer Without spacer 0 to 25 25 to 50 50 to 75 MY163 Short spacer Without spacer Long spacer Table 1: Stroke adjustment range (Without spacer, with short spacer, with long spacer) Warning 1.
Low frequency operation Valves should be operated at least once every 30 days to prevent malfunction. (Use caution regarding the air supply.)
Take appropriate measures so that a force of 30 N or more is not applied to the lead wire. Lubrication 1. When extremely dry air is used as the fluid, degradation of the lubrication properties inside the equipment may occur, resulting in reduced reliability (or reduced service life) of the equipment. Please consult with SMC. 1.
Table 1: Stroke adjustment range (Without spacer, with short spacer, with long spacer) -10 -20 -30 -40 -50 0 0 to 10 10 to 20 20 to 30 L unit MY2*16 Without spacer Short spacer Long spacer H unit 0 to 12 12 to 24 24 to 36 L unit MY2*25 Without spacer Short spacer Long spacer H unit 0 to 16 16 to 32 32 to 48 L unit H unit Without spacer MY2*40 Short spacer Long spacer -9- Warning 1.
. -10 -20 -30 -40 -50 -60 -70 -80 0 0 to 10 10 to 20 20 to 30 MY3*16/20 Without spacer Short spacer Long spacer 0 to 12 12 to 24 24 to 36 MY3*25/32 Without spacer Short spacer Long spacer 0 to 16 16 to 32 32 to 48 MY3*40/50 Without spacer Short spacer Long spacer 0 to 24 MY3*63 24 to 48 48 to 72 Without spacer Short spacer Long spacer Table 1 Stroke adjustment range (Without spacer, with
Low frequency operation Valves should be switched at least once every 30 days to prevent malfunction.Use caution regarding the air supply.. Manual override operation When the manual override is operated, connected equipment will be actuated. Confirm safety before operating.
Warning Rc1/8 7 to 9 Rc1/4 12 to 14 Rc3/8 22 to 24 Rc1/2 28 to 30 6. Piping to products When piping to a product, avoid mistakes regarding the supply port, etc. 6 No.VF1000-OMN0002-A VF1000/3000/5000 Series Precautions for 5 Port Solenoid Valve Be sure to read before handling. Refer to main text for detailed precautions on every series. 9.