(Maximum 10 stations) Example) IITV00-05-07 02 03 2 stations 3 stations Indicate part numbers in order starting from the first station on the D side. 10 10 stations Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. Note) A DIN rail with the length specified by the number of stations is attached to the manifold.

VK300-37-2-01 VK300-37-2-02 VK300-37-2-07 VK300-37-4-51 VK300-37-4-06 VK300-37-3-05 VK300-37-3-53 Rated voltage 100VAC 200VAC 240VAC 6VDC 12VDC 24VDC 48VDC Rating symbol A1 A2 A3 LW06 LW2 LD4 LD8 DIN terminal Circuit diagram for connector with light The bushing may be damaged if the tightening torque of 0.8Nm is exceeded.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nozzle diameter 05 0.5 mm ZL 07 0.7 mm Circuit diagram ZY EXE ZQ Specifications ZF Fluid Air P V ZP Maximum operating pressure 0.7 MPa Standard supply pressure 0.45 MPa ZCU Operating temperature range 5 to 60C Applicable tubing O.D.

Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD, VACUUM EJECTOR, M82, 114 lb

._3d_items_collection = {}; } SMC KQ2P-07 fitting, plug, KQ2 FITTING (sold in packages of 10; price is per piece) $0.92 + Add to Quote Add To Cart Add to Cart SMC SX5000-16-1A

This is a legacy product, and replaced byZK2G10K5HLA-07-BJ, Vacuum Ejector, VACUUM EJECTOR, 99 lb

This is a legacy product, and replaced byZK2B10K5RWA-07, Vacuum Ejector, VACUUM EJECTOR, 99 lb

Please contact us for the latest version.sales@ocaire.com, MANIFOLD, 07-STA., VACUUM SERIES, ZZM MANIFOLD UNIT, 2D, ZZM NO SIZE RATING, .54895 lb

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]

System: P (Vacuum Pump System, Single Unit), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: None, Pump System PE Port Female Thread: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum

Body Class: 2 (ø4 Orifice), Valve Type: 0 (N.C.), Fitting Type: V (LQ1, Body Class: 2, 3, 4, 5, 6), Fitting Size: 07 ( Tubing O.D. 1/4)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 07 (ø1/4), Sealant: without Sealant, Push lock: A (Push-lock)

Body Size: 2 (1/8, 1/4), Type: 3 (Universal), Control Type: 1 (Meter-in), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: N (NPT), Port Size: 02 (1/4), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 07 (ø1/4), Sealant: without Sealant, Push lock: A (Push-lock)

Body Size/Type: 12 (Elbow Size M5), Control Type: 0 (Meter-out), 1: 1, Thread Type: (R Thread or In-Line Type), Port Size: U10/32 (10-32UNF), Applicable Tubing O.D: 07 (ø1/4")

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit

Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/

. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]

Body Class: 2 (ø4 Orifice), Valve Type: 0 (N.C.), Tube Size: 07 (1/4"), Pilot Port Thread: M (LQ3 Integral Fitting, 4mm), Pilot Port Direction: P3 (Direction 3)

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: QB (DeviceNetâ„¢ - 16 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 07 Stations, P, E Port Location: D (D Side), SUP/EXH Block: R (External Pilot), A, B Port Size: C6 (ø6 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate