Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: S (w/Flow Adj.
Base Mounted Wiring: 01FD (Plug-in w/D-sub Connector on D Side), Stations: 04 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 06 (3/4), Thread: T (NPTF)
, °C; Pressure Gauge: psi (and MPa)], D: D
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa, D: D
Stations: 03 (3 Stations), Supply/Return Unit Layout: D (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Stations: 03 (3 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.
Stations: 04 (4 Stations), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: P (w/o Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: ET (Out 1: PNP; Out 2: Flow Rate: Analog 1 to 5 V ⇔ Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Applicable manifolds include serial transmission types, D-sub connectors, flat ribbon cable, PC wiring system compatible, flat ribbon cable, terminal block, lead wire, and circular connectors. Fieldbus serial transmission system (EX600), SI unit for input/output , Kit types include DeviceNet?, PROFIBUS-DP, CC-Link, EtherCAT, and EtherNet/IP?
Applicable manifolds include serial transmission types, D-sub connectors, flat ribbon cable, PC wiring system compatible, flat ribbon cable, terminal block, lead wire, and circular connectors.
Applicable manifolds include serial transmission types, D-sub connectors, flat ribbon cable, PC wiring system compatible, flat ribbon cable, terminal block, lead wire, and circular connectors.
Stations: 06 (6 Stations), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Flow Switch Type: 7 (Integrated Display), Rated Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: Flow Adj.
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None)
Valve: None; Stop Valve: None, Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 1 (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: None; Temperature Sensor: None)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Voltage: 3 (110 to 120 VAC, 50/60 Hz), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: N (NPT)
Function: 1 (2 Position, Single), Model: 1 (Non Plug-in), Body Option: 1 (Direct Manual Override), Voltage: 5 (24 VDC), Lead Wire: D (DIN Terminal), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Port Size: 06 (3/4), Thread: T (NPTF)
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: S (w/Flow Adj.
Stations: 06 (6 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal; Temp