Water Separator w/possible modular connection, Water removal rate: 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide, IN-OUT reversal direction, degreasing wash, white vaseline, WATER SEPARATOR, WATER SEPARATOR, 131, 2.1 lb
Water Separator w/possible modular connection, Water removal rate: 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide, IN-OUT reversal direction, degreasing wash, white vaseline, WATER SEPARATOR, WATER SEPARATOR, 131, 4.2 lb
Water Separator w/possible modular connection, Water removal rate: 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide, IN-OUT reversal direction, degreasing wash, white vaseline, WATER SEPARATOR, WATER SEPARATOR, 131, 0.55 lb
Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cyl, Slide Table, Clean Series, GUIDED CYLINDER, D77, 131 lb
Water Separator w/possible modular connection, Water removal rate: 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide, IN-OUT reversal direction, degreasing wash, white vaseline, WATER SEPARATOR, WATER SEPARATOR, 131, 0.9 lb
Air Operated 5 Port Valve, AIR OPERATED VALVE, 131 lb
Water Separator w/possible modular connection, Water removal rate: 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide, IN-OUT reversal direction, degreasing wash, white vaseline, WATER SEPARATOR, WATER SEPARATOR, 131, 0.55 lb
Water Separator w/possible modular connection, Water removal rate: 99% , Max operating pressure: 1.0MPa , Options: Fluororubber material, medium air pressure, drain guide, IN-OUT reversal direction, degreasing wash, white vaseline, WATER SEPARATOR, WATER SEPARATOR, 131, 0.9 lb
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE MECHL 1/4, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .47242 lb
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE, MECHANICAL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .83775 lb
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE, MECH, NPT, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .66000 lb
The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 22 to 131 PSIG, Effective area (Cv): 18mm 2 (1.0), Maximum frequency (mechanical operation style): 300 c.p.m. or less, Weight (Basic): 9.2 oz., VALVE, MECH, NPT, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .68200 lb
When 0002H is selected for the Torque Unit (parameter 47), set the Torque Base Unit (parameter 48) to 0. 8-131 8 MECHATROLINK-III Commands Parameter Name Setting Units Factory Enabled Size Category No.
output) Operating voltage range 24 VDC +10%/-10% For logic/input Under-voltage detection approx. 16.8 VDC For output Operating voltage range 24 VDC +10%/-5% Isolation Yes (Between power supplies for logic/input and output) Fieldbus Bus protocol IO-Link Version 1.1 IO-Link type Device IO-Link Port Class Class B Transmission rate COM2 (38.4 kbps) Firmware update function Yes Vendor ID 0x0083 (131
L N PE To the users machine Terminal connecting screw: M3 Crimped terminal width: 6.5mm or less Applicable electric wire: 1.25mm2 or more Rubber grommet Power supply cable entry IDF Series 13-1 Safety instructions 131 IDX-OM-W010 Air Dryer 13 Specification for Option S IDF4E/6E/8E/11E/15E Rear panel You can see the terminal block when you remove this cover.
Front L N PE To the users machine Terminal connecting screw: M3 Crimped terminal width: 6.5mm or less Applicable electric wire: 1.25mm2 or more Rubber grommet Power supply cable entry 131 13.
Also, the frequency of starting and stopping should be 5 times per hour or less (to prevent the motor failed.) 13-1 Safety instructions 131 IDF Series IDX-OM-W025 Air Dryer 13 Specification for Option T 13-4 How to connect the power and signal cable Connect the power cable and signal cable in the following procedures. 1) Take off the front panel. 2) Insert the power cable prepared by the
The operation and failure signals are no voltage contact style OperationWhen the product is operating; Close FailureWhen the product stops due to failure; Close Contact capacity AC200V / 2A DC24V / 2A (Minimum applicable load: 20V / 3mA) 13-1 Safety instructions 131 IDU Series IDX-OM-W022 Air Dryer 13 Specification for Option T 13-3 Remote operation When a remote operation is used, the switch
Direct parameters page 1 Address Access Parameter name Default (decimal number) 0x07 R Vendor ID 0x0083(131) 0x08 0x09 R Device ID 0x0219(537) 0x0A 0x0B 11 - ISDU parameters ISDU Data Access Value Index *1 Parameter name storage (decimal number) Subindex *2 0x0002 (2) 0 W System Command N For more details, refer to "System command."
S. or l ess O perat i ng t em perat ure 0 t o 50( N o dew condensat i on) St andards CE m arki ng, U L( CSA) Encl osure I P65 I P65 equi val ent M odel I TV10 0 I TV20 0 I TV30 0 Si ze ( m m m m m m ) 50 50 109 50 50 131 66 66 152 W ei ght ( N o opt i on) 320 420 720 9 Com m uni cat i on speci f i cat i on ( Com m on) I t em Speci f i cat i ons Rem arks Fi el d bus D evi ceN et Rel ease2