In this case, all (DI-1) input signals and (DO-1) output signals are of source type. wire according to the following interfaces. (1) Digital input interface DI-1 Driver Servo amplifier EMG, etc. Approx. 5.6k Switch DICOM 24VDC 10% 150mA Approx. 5mA VCES 1.0V ICEO 100 A (2) Digital output interface DO-1 A maximum of 2.6V voltage drop occurs in the driver.

Do not use a fluid containing chemicals, synthetic oils including organic solvent, salt and corrosive gases. Otherwise damage to the product, malfunction and failure can result. Writing time of input data to product is 10 times. Design The product should be positioned higher than the detection nozzle.

force (N) Stroke/both sides (mm) Size Stroke/both sides (mm) Stroke/both sides (mm) Size Size Size Basic Compact 4 6 10 14 22 30 Basic Compact 4 6 10 14 Basic Compact 4 6 8 12 10 16 20 25 32 40 10 16 20 25 10 20 32 40 10 20 32 40 5.5 22 90 130 6 8 6 8 7 28 120 180 16 (32) 24 (48) 32 (64) 40 (80) 3.5 17 14 14 28 28 40 40 130 210 Note) ( ): Long stroke Features 13 Controller/Driver Controller

DDH10 (Hole) Bore size (mm) DA DL DU DC DX DE DO DR DT DS DH DF B Z Part no. 40 CA2-B04 +0.058 0 57 35 65 15 85 10 9 17 40 52 165 11 8 60 10 50 CA2-B05 +0.070 0 57 35 11 65 18 85 10 9 17 8 40 52 70 183 12 63 +0.070 0 CA2-B06 67 40 80 25 105 12.5 11 22 50 66 196 13.5 10 85 16 80 +0.084 0 CA2-B08 93 60 16.5 100 31.5 130 15 13.5 24 12 65 90 102 235 20 100 +0.084 0 CA2-B10 93 60 16.5 100 35.5

Contact SMC especially if a clean environment is required. 10 - 2-3. Mounting The foot mounting cylinder has a hole in the foot to drive a pin into for accurate positioning and fixing. C a u t i o n Do not apply excessive lateral load to the piston rod. Please refer to Chart 9. Allowable lateral load applied to rod end.

Do not connect the earth to a water pipe, a gas pipe, or a lightening rod. Do not plug too many leads into a single socket. That causes exothermic heat or fire. Do not convert the wiring to use.

Piping 10 7.1 Piping connections to the PD Ports 10 7.2 Piping connections to the Supply (P) port 11 8. Construction 12 9. Dimensions 15 10.

Bit number Value meaning 31 (MSB) X do not care 0 Device does not generate SYNC message 30 1 Device generate SYNC message 0 11 bit ID (CAN 2.0A) 29 1 29 bit ID (CAN 2.0B) 0 if bit 29 = 0 28 to 11 X If bit 29 = 1: bits 28 to 11 of 29-bit-SYNC-COB-ID 10 to 0 (LSB) X bits 10 to 0 of SYNC-COB-ID : The default values when the SI unit is supplied. Bits 29 to 11 are fixed (not changeable).

Do not operate at pressures, temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air (including vacuum). We do not guarantee against any damage if the product is used outside of the specification range. 10.

Do not touch the LCD indicator. Do not touch the LCD indicator face of the pressure switch during operation. Static electricity can change the readout. 3. Pressure port Do not introduce any wire or similar object to a pressure port as this may damage the pressure sensor and cause a malfunction. Warning 1. Do not use in an area where surges are generated.

10 ISO Class 8 10 10 0 L/min (ANR) ISO Class 7 ISO Class 7 10 10 Particle concentration [particles/m3] Particle concentration [particles/m3] ISO Class 6 ISO Class 6 10 10 0 L/min (ANR) 50 L/min (ANR) ISO Class 5 ISO Class 5 10 10 1000 1000 20 L/min (ANR) ISO Class 4 ISO Class 4 100 100 70 L/min (ANR) 30 L/min (ANR) 10 10 1 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0 0.1 0.2 0.3 0.4 0.5 0.6 Particle diameter

weight m (kg) Load weight m (kg) 30 30 MGF63 10 20 20 MGF63 5 10 10 MGF40 5 4 3 5 4 3 MGF40 MGF40 5 MGF40 2 2 3 5 2 1 1 10 20 30 40 50 100 200 300 400 10 20 30 40 50 100 200 300 400 10 50 100 5 10 50 100 Eccentric distance l (mm) Eccentric distance l (mm) Stroke (mm) Stroke (mm) How to read the graph 1) When the load weight is 70kg, eccentric distance is 60mm, and the maximum speed is 150mm

Contact SMC especially if a clean environment is required. 10 - 2-3. Mounting The foot mounting cylinder has a hole in the foot to drive a pin into for accurate positioning and fixing. C a u t i o n Do not apply excessive lateral load to the piston rod. Please refer to Chart 9. Allowable lateral load applied to rod end.

Please do not apply force to the coil and frame when installing the piping and valves. If they receive 10 N or more of force, a malfunction may occur. 3. Do not pull the lead wire with excessive force. Applying 10 N or more of load may result in broken wire or contact failure. Manual Override Caution 1.