SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-05-D"

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 05 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: N7 (ø1/4" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate, w

Stations: 05, Systems, Port Combinations: PN [Vacuum Pump System, ø5/16" (Common PV), ø1/4" (Common PS)], Exhaust: 2 (Individual Exhaust), Wiring: L (Individual Wiring), Bracket: B (w/DIN Rail Mounting Bracket), Common Release Pressure Supply: D [w/Common Release Pressure Supply (PD) Port], Manifold Individual Supply: w/o Option

Series: 1 (10-SV1000), Base Type: 10FD, Connector Entry Direction: 1 (Upward), Valve Stations: 05 (5 Stations), P, E Port Location: U (U Side, 2-10 Stations), Pilot Type: Internal Pilot, A, B Port Size: C4 (One-touch Fitting for Ø4), Mounting: D (DIN Rail Mounting w/DIN Rail)

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: JK (with Unit Options J & K), 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection Supply Valve

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: H (High Noise Reduction Silencer Exhaust), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal Nozzle Size: 4 (ø1.5), 1st Selection

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: without Option, Exhaust: F (Individual Port Exhaust), Pressure Switch for Vacuum/Pressure Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 2 (ø1.0), 1st Selection Supply

Stations: 05 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal Nozzle Size: 0 (for Vacuum Pump

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: Rc, Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Stations: 05 (5 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: P (w/o Flow Adj.

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 05 Stations, P, E Port Location: U (U Side), SUP/EXH Block: Internal Pilot, A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: Positive Common, NPN or w/o SI Unit, Valve Stations: 05 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: Internal Pilot, A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name

Series: SS5Y3 (SY3000 Manifold), Model: 10S (Side-Ported, Serial Interface), SI Unit Specification: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (PNP), Valve Stations: 05 Stations, P, E Port Location: B (Both Sides), SUP/EXH Block: S (Internal Pilot, Built-in Silencer), A, B Port Size: LN7 (ø1/4" One-touch Fitting, Upward Elbow), Mounting: D (DIN Rail Mounting