Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0
Blow Velocity Distribution (Supply Pressure: 0.3 MPa) qEnergy saving static neutralization nozzle IZN10E-01 wHigh flow rate nozzle IZN10E-02 0 0 100 100 Distance [mm] Distance [mm] 200 200 4 m/s 14 m/s 300 300 11 m/s 3 m/s 400 400 8 m/s 2 m/s 500 30 30 20 10 0 10 20 500 30 30 20 10 0 10 20 Distance (Horizontal) [mm] Distance (Horizontal) [mm] 8 IZN10E Series Flow Rate Characteristics qEnergy
0 Controller/Driver mounting LEC Nil Screw mounting D DIN rail mounting LEC S DIN rail is not included. Order it separately.
1) D-Z8 type D-A9 type D-F9 type D-Y6 type Ball bushing D-Y7 type Note 1) Vertical outlet types cannot be mounted.
C D UJB F8N Number of auto switches Nil S 2 pcs. 1 pc.
01 T1 01 T1 I Z PFl Pressure setting trimmer Pressure setting trimmer Pressure setting trimmer Pressure setting trimmer IFl HYS HYS SET SET 15 15 Indicator light Indicator light 23 23 I Z I Z SE1-01 -16, -17 SE1-01 -16C, -17C Pressure setting trimmer 1 Pressure setting trimmer 2 Pressure setting trimmer 1 Pressure setting trimmer 2 SET2 SET2 SET1 SET1 15 15 Indicator light Indicator light
/M5W/M5TL D-E7A/E80A D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
/M5W/M5TL D-E7A/E80A 25 6 4 32 6 4 D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
Series
Foundation bolt L1 (mm) Nominal thread size d M16 L1 R Applicable model d1 S L Part No. (Approx.) (Approx.) FGF-OP05 Hexagon nut d FGF1-20 16 40 71 31.5 400 R d1 FGF3-40 AI-3S M20 20 50 90 40 500 FGF5-60 S Note) 3 foundation bolts are required per filter unit. If ordering only foundation bolts, order 3 bolts using the above part number.
Add -61 at th end of the part number for the flexible lead wire except D-Y59, D-Y69, DY7 and D-M9/M9V type auto switches. L D-A73 (Example) CLQ Lead wire length MLGP 5 m None Nil L 0.5 m 3 m Z N RLQ Applicable for the connector type (D-C) only.
How to Order B 32 30 D C CQ2Y Standard B F9BW S 32 30 D C CDQ2Y With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-14 Connection of RS-232C 3.3.10 Ethernet Modbus/TCP Communication wiring This product can operate the following by Ethernet Modbus/TCP communication.
Note 12 16 20 25 32 40 50 D-F7 , J79 D-F7 V D-J79C D-F7 W, J79W D-F7 WV D-F7BAL, F7BAVL D-F79F D-F7NTL D-F7, D-F7V D-J79, D-J79C D-F7W, D-F7WV D-J79W D-F7BAL, D-F7BAVL D-F7NTL, D-F79F -X Switch mounting screw (M3 x 0.5 x 10 ) Switch spacer Switch mounting nut D-A7 , A80 D-A73C, A80C D-A7 H, A80H D-A79W 6 6 6 32, 40 50 BQ-2 20Data D-F9W, D-F9WV D-F9BAL 5.5 3 4 5 5.5 5.5 5.5 Switch mounting
M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13
D F9NV S MIW Double finger type 20 30 1 A S D F9BV S Single finger type MIS Scraper Cylinder bore Nil S No Yes Number of auto switches 12mm 20mm 12 2 pcs. 1 pc.
and case Insulation resistance 5 M between external terminals and case (at 50 VDC) Vibration resistance 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized) 980 m/s2 in X, Y, Z directions, 3 times each (De-energized) Impact resistance Temperature characteristics (Based on 25C) 2% F .S. or less based on the
Combination of R and S (Because S function is also included in R.) Combination of S and T (Because S function is also included in T.) Combination of K and V (Only one or the other may be attached.) Note 2) Standard specification is the power cable with plug.
Example: VEX1300-03 G36-4-01 (Constructive symbol) 5.1-1 VEX1 How to Order 1 03 D 3 1 0 B VEX Regulator valve B Bracket Option F Foot (Only VEX110) G Gauge When specifying more than one option, combine symbols in alphabetical order. 0 Air operated Operating style 1 External pilot solenoid None Indicator light and surge voltage suppressor S Surge voltage suppressor Z Indicator light and