Note 3) q Ambient temperature: 25C, w Circulating fluid temperature: 20C, e Circulating fluid rated flow, r Circulating fluid: Tap water Note 4) Temperature at the thermo-chiller outlet when the circulating fluid flow is rated flow, and the circulating fluid outlet and return port are directly connected.

3 @2 @1 @5 !1 !0 Section AA' @0 u @8 r y !6 @3 @4 e !7 w i t q Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A A' @6 #2 @8 @9 #0 !8 !9 #1 @7 !4 !

0 @2 @1 #2 ^2 ^5 $5 %2 @5 ^8 $4 ^1 @4 %4 %5 ^7 $3 #0 $2 %6 @7 ^4 o %7 ^9 ^6 @9 %8 ML2BS $1 %3 ^3 !

8 22 8 15 80 18 M6 x 1 20 40 36 M26 x 1.5 124 13 10 70 41 41.6 3 16 11 29 10 16 92 23 M6 x 1 26 50 46 M32 x 2 150 13 TF TN Nil P (Piping port) ZZ X W TT Model 12-REA25 12-REA32 12-REA40 50 Rc1/8 30 NPT1/8 137 G1/8 17 50 Rc1/8 40 NPT1/8 156 G1/8 19 60 Rc1/4 40 NPT1/4 182 G1/4 22 12-REA50/63 0 L0.2 33 B 2 x 4 x V Effective thread depth 16 2 x P (Piping port) 14 14 8 (R) D X Q Q 14.5 22 I 2

0.05 to 0.85 MPa 0.05 to 0.30 MPa 0 1 ARX21 Nil F Note 1) Thread type (2) G Pressure gauge ARX20N Rc NPT G Nil N F ARX21N P Port size Panel nut 01 02 1/8 1/4 Option combination numbers Panel nut is also included with B.

wire (NPN) 3 wire (PNP) IC circuit A96 A96V 5V F9N F9NV F9P F9PV 2 wire F9B F9BV Relay, PLC Grommet Yes 12V 24V 3 wire (NPN) 3 wire (PNP) F9NW F9NWV Diagnostic indication F9PW F9PWV 2 color indicator 2 wire F9BW F9BWV Lead wire length symbols: 0.5m Nil (Example) F9NW 3m...

Close the valves at inlet and outlet. 3-2. Open the air vent and drain valves and make the pressure inside the filter zero (0) in order to discharge all fluid inside. 3-3. Loosen the bolt and nut of q and w for tightening the filter cover and filter case meanly little by little. When the nut can be turned with hand, remove them one after another in order from the end. 3-4.

Close the valves at inlet and outlet. 3-2. Open the air vent and drain valves and make the pressure inside the filter zero (0) in order to discharge all fluid inside. 3-3. Loosen the bolt and nut of q and w for tightening the filter cover and filter case meanly little by little. When the nut can be turned with hand, remove them one after another in order from the end. 3-4.

K 10 L 14 N 90 O 55 P 110 Q 50 R 88 S 3.2 36 9 205 19 100 106 3 106 10 1 2 3 4 , AME450 Misc. 212 22 107 106 3 106 10 36 221 21 10 14 9 90 55 110 50 88 3.2 1 , , , 1 1 3 4 4.5 4.5 6 257 314 406 30 40 30 10 15 15 16 20 24 100 150 180 65 85 120 130 180 220 60 76 110 102 136 184 44 66 96 9 11 13 239 291 403 22 32 42 128 167 235 122 160 220 3 122 160 220 10 10 10 AME550 AME650 AME850 1 2 1

Model AMG150 AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 Model Note) Rated flow (l /min (ANR)) 300 750 1500 2200 3500 6000 12000 Port size (Nominal size B) , , , , , , , , , , , 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note) Max. flow capacity at a pressure of 0.7 MPa. Max. flow varies depending on operating pressure.

AMH250 AMH350 AMH450 AMH550 AMH650 AMH850 AMH150 Model Note) 500 1000 2000 3500 6000 12000 200 Rated flow (l/min (ANR)) Port size (Nominal size B) 1 8 1 4 3 8 1 4 3 8 1 2 3 8 1 2 3 4 1 1 2 3 4 1 3 4 1 1 1 2 1 2 1 2 , , , , , , , , , , , 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Weight (kg) Note) Max. flow capacity at pressure of 0.7 MPa. It varies depending on operating pressure.

3 i w u o y q Section B-B' (Solenoid valve) Component Parts Replacement Parts Note Description Material Description Part no. No. No. SY114Urban white Resin Manifold block 3 port solenoid valve q o ZSE1-00--X130 Urban white Zinc die-casted Body Vacuum switch w !0 Urban white Resin Silencer cover P44027A End plate assembly e !1 Aluminum Nozzle AN203-KM8 Silencer r !

Controller ID: 1 Function code: 05h Start address: Y30 Data value to be written: "FF00h" (i) Request Example 1 Start code 2 ID 0 Controller ID: 1 3 1 4 Function code 0 Function code: 05h 5 5 6 0 Address No. of 7 0 contact to be Start address: Y30 8 3 written 9 0 Data 10 F 11 F Data value to be Data value to be written: "FF00h" written Note 1) 12 0 13 0 Calculated 14 value Checksum(LRC) 15

Refer to the page 58 for details. 4.5 5 5 Circuit Diagram Power supply terminal block PCW-EC16Z00 PCW-EC16Z01 20 18 16 14 12 10 8 6 4 2 Input/output connector (CS0) 0 1 2 3 4 5 6 7 19 17 15 13 11 9 7 5 3 1 Green Red F E D C B A 9 8 9 8 7 6 5 4 3 2 1 0 F E D C B A 4 3 2 1 CN1 4 3 2 1 CN2 4 3 2 1 CN3 4 3 2 1 CN4 4 3 2 1 CN5 4 3 2 1 CN6 4 3 2 1 CN7 4 3 2 1 CN8 4 3 2 1 CN9 4 3 2 1 CNA 4 3 2 1

For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet (B59W) G79 Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP) IC circuit

For detailed specifications, please contact SMC. 100 V Relay, PLC Yes 100 V, 200 V 12 V 24 V (B54) B54 B73C 2-wire 12 V C73C B59W H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7BA H7NF PLC Grommet (B59W) G79 Diagnostic indication (2-color indication) 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V K79 Grommet 2-wire 12 V K79C Connector Relay, PLC Yes 24 V 3-wire (NPN) 3-wire (PNP) IC circuit

Model AMG250 AMG350 AMG450 AMG550 AMG650 AMG850 AMG150 (1) Flow rate (l /min (ANR)) 750 1500 2200 3500 6000 12000 300 Port size (Nominal size B) 1/8, 1/4, 3/8 1/4, 3/8, 1/2 3/8, 1/2, 3/4 1/2, 3/4, 1 3/4, 1 1, 11/2 11/2, 2 Weight (kg) 0.38 0.55 0.9 1.4 2.1 4.2 10.5 Note 1) Max. flow is at 0.7MPa. Max. flow depends on operating pressure.

/N.O. 1/8 to 3/4 0 to 3 (1) 17-2-57 VV2CW2/3/4 N.C./N.O. Manifold 2, 3, 4, 5, 7 1/8, 1/4, (3/8) 17-2-64 VDW10/20/30 Single unit N.C. M5, 1/8, 1/4 1, 1.6, 2.3, 3.2 2, 3, 4 0 to 0.9 (1) 17-2-68 VV2DW1/2/3 N.C. Manifold M5, 1/8, 1/4, (3/8) Solenoid valve 17-3-17 VX21/22/23 N.C./N.O. Single unit 2, 3, 4.5, 6, 8, 10 1/8 to 1/2 0 to 3 (1) 17-3-25 VVX21/22/23 N.C./N.O.

MGQM, MGQL Common Dimensions Bore size (mm) Standard stroke (mm) B Z G NN F MM ML DA L R C H K Q X GA GB J P PW S T TA TB V W YY YL 32 40 50 63 80 100 1/8 1/8 1/4 1/4 3/8 3/8 16 17 17 19 21 25 51 51 59 72 92 112 12.5 14 14 16.5 19 23 114 96 48 112 80 100 8 8 10 10 16 16 20 20 25 25 30 35 16 16 20 20 25 30 38 38 44 44 56 62 37.5 44 44 49 56.5 66 26 26 30 36.5 46.5 56.5 30 30 40 50 60 80 47.5

[F 2] 2 Press the button once to reduce the value by one digit, press and hold to continuously reduce. : Display set by customer [F 3] [FiL ] Select digital filter [ 1.0] 1 second Product number Suitable screws Tightening torque Thread depth [F 5] [FUnC] Select FUNC (switching analogue output 3/external input) [AoUt] Analogue output Align the master IO-Link version to the device.