SMC Corporation of America
Elite Part Number Search
Search Results "RZQL32-150-70-M9BL3"

Weight (g) Port size Body ported VZ110 VZ120 70 M5 x 0.8 0 to 0.5 Note ) Weight stands for grommet type Flow Characteristics Flow characteristics Type of actuation Port size N.C.: 1 2 (P A) N.O.: 3 2 (R A) N.C.: 2 3 (A R) N.O.: 2 1(A P) Supply side Exhaust side Model C [dm3/(sbar)] C [dm3/(sbar)] b Cv b Cv Body ported VZ110 VZ120 N.C. 0.11 0.19 0.026 0.071 0.023 0.042 0.19 0.13 0.071

kg, eccentric distance is 60 mm, and the maximum speed is 150 mm/s Select MGF100 from Graph . 2) When MGF63 is operated with a load mass 30 kg and 100 mm eccentric distance From Graph , the cylinder can be used at a maximum speed of 100 mm/s or less. 411 Guide Table Series MGF 40, 63, 100 How to Order Port thread type Nil TN TF Rc NPT G MGF 63 30 M9BW Made to Order Refer to page 413 for

122 151 70 122 151 48 374 836 52 402 1000 Slide screw + Linear guide: 53dB (LJ1H) Low profile/non-coupling type with reduced height and length Low Profile Electric Actuator Series LG1 Series with coupling available Mounting of a non-standard motor is possible.

4 to 20 mA DC Current type 0 to 20 mA DC Voltage type 0 to 5 VDC Voltage type 0 to 10 VDC Preset input 20 Output pressure (kPa) Nil B Without bracket Flat bracket L-bracket 30 40 C Option 50 Monitor output Thread type Port size Option 60 2 1/4 0 Without (In the case of preset input) Analog output 1 to 5 VDC Switch output/NPN output Switch output/PNP output Analog output 4 to 20 mA DC 70

32 50 50 7 60 120 96 118 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 9 66 140 96 133 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 163 64 50.8 196 68 60.5 1 2, 3 4 4-16-7

Operating Pressure and Operating Temperature Specifications ZFC5 Model ZFC7 Max. operating pressure [MPa] 1.0 Metric size Inch size 12 10 3/8" 8 5/16" 6 1/4" 6 1/4" 4 5/32" Port size (Applicable tubing O.D.) 0.8 Fluid Operating pressure Air, Nitrogen 100 kPa to 1.0 MPa 0.6 Flow rate (Positive pressure) L/min Note) 350 100 300 80 250 70 120 30 100 20 45 10 0.4 Flow rate (Vacuum pressure)

1690 60 100 182 282 2560 25 MHZ 40 120 200 320 2775 70 150 220 2905 30 MHF 120 198 318 3820 32 20 MHL 160 242 402 4655 100 188 288 5270 30 JIS Symbol MHR 160 246 406 6830 40 20 200 286 486 7905 MHK Note) The open and close time spans represent the value when the exterior of the workpiece is being held.

RESET Ctrl Comm ALM (1-150) D SVON Do not remove the cable during operation by the controller setting kit or teaching box. Input *1) Abnormality in communication with the encoder. Encoder ALM (1-192) E Power off Check the connection of the actuator cable. Unable to find the motor phase within the set time.

Grease pack part number: GR-L-005 (5 g), GR-S-010 (10 g), GR-L-150 (150g) Nickel plated Carbon steel Piston nut 11 Nickel plated Carbon steel Flat washer 12 Resin Wear ring 13 Magnet 14 Phosphate coded. Spring steel Retaining ring 15 NBR Rod seal 16 Cushion seal Urethane 17 NBR Piston seal 18 Dimensions NBR Valve seal 19 External dimensions are the same as the CS2 standard type.

(AWG20 to 40) AWG20 AWG30 AWG40 AWG20/30/40 Hook spanner Nominal AWG20 AWG30 AWG40 Tightening torque 2.0 0.2 Nm 3.5 0.3 Nm 4.0 0.4 Nm AWG20 AWG30 AWG40 52/55 58/65 65/70 Actuators Modular F.R.L.

Air Proof pressure 1.05 MPa Maximum operating pressure 0.5 MPa Minimum operating pressure Note 1) 0.005 MPa 10 to 80C Ambient and fluid temperature Cushion Rubber bumper (Provided as standard) Lubrication Note 2) Not required (Non-lube) Rod end thread Female thread Rod end thread tolerance JIS class 2 +1.0 0 Stroke length tolerance Piston speed Note 3) 0.3 to 300 mm/s (Refer to page 19.) 150

122 151 70 122 151 48 374 836 52 402 1000 Slide screw + Linear guide: 53dB (LJ1H) Low profile/non-coupling type with reduced height and length Low Profile Electric Actuator Series LG1 Series with coupling available Mounting of a non-standard motor is possible.

frequency [Hz] 70 50 150 100 Valve Construction 2-position single 2-position single Standard 5-port specification Made to Order 3-port specification (-X1) q w 3 (EB) 1 (P) 5 (EA) 3 5 1 3 5 1 2 4 2 4 Component Parts No.

(psi) Nominal ~upport bracket nominal ~ymbo l symbol ~nd~cJjemallc diagram " Rod f1ang~: Head flange: --i '< "C II> 92 113 103 Fooi: L 44 G .F. " [I" , , III 1 L,F 73 79 70 86 :.T w~ 102 58 66 72 44 45 47 38 en 3 0 0 ~ "'i f" 27 73 34 33 G 22 102 27 26 (') 'cS. ,j" C. r '\ ~ T .

(mm) Model Conversion Cv 1.2 1.3 1.5 3.9 5.0 4.5 5.8 7.0 11 9.1 15 17 23 17 23 26 34 30 40 41 62 41 66 49 70 73 100 Threaded Note) Flange Kv VNC1-6A VNC1-8A VNC1-10A VNC24-10A VNC2-10A VNC24-15A VNC2-15A VNC34-20A VNC3-20A VNC44-25A VNC4-25A VNC54-32A VNC5-32A VNC54-32F VNC5-32F VNC64-40A VNC6-40A VNC64-40F VNC6-40F VNC74-50A VNC7-50A VNC74-50F VNC7-50F 1 8 1 4 1.1 1.1 1.3 3.4 4.3 3.9 5.0

200 10 50 100 150 200 250 15 600 500 400 300 200 100 20 200 400 600 800 1000 25 200 400 600 800 1000 1200 1400 Flow rate Q [kg/h] ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) For Water How to read the graph The pressure differential to generate a flow rate of 25 L/min water is as follows.

Cushion adjustment (Relief adjustment) man-hours are the same as the adjustment (cushion needle adjustment) for general purpose cylinders. 350 High power cylinder 300 General purpose cylinder (SMC Series CG1) Buffer capacity [kgf cm] Quality of cushioning (RHCF40-500, Load weight 5kg, Supply pressure 0.5MPa, Horizontal operation) 250 500 3000mm/s 1000mm/s 2000mm/s 200 500mm/s 400 150 Deflection

kg, eccentric distance is 60 mm, and the maximum speed is 150 mm/s Select MGF100 from Graph (7). 2) When MGF63 is operated with a load weight 30 kg and 100 mm eccentric distance From Graph (6), the cylinder can be used at a maximum speed of 100 mm/s or less. 8-23-5 6 Guide Table Series MGF 40, 63, 100 How to Order MGF Y7BW 30 63 Number of auto switches Nil 2 pcs.

PV SV 5.19 Communication function HRS Series 5-70 HRX-OM-M090 Chapter 6 OptionOptional Accessories Chapter 6 OptionOptional Accessories 6.1 Option J [Automatic fluid filling] 6.1.1 Option J [Automatic fluid filling] This function is available for customers who selected automatic fluid filling.