Flow rate L/min (ANR) SFB20-02 0.1 Inlet pressure Max. flow rate line 0.3 MPa Pressure drop MPa 0.1 MPa 0.01 0.7 MPa 0.5 MPa 0.001 0.0001 1000 10 100 Flow rate L/min (ANR) 304 SFB100/200 Series Clean Gas Filter/Clean Gas Strainer: Cartridge Type/Straight Type Dimensions SFB100/200: Rc 1/4 SFB101/201: NPT 1/4 SFB104: M5 HAA HAW Bracket 2 x M5, Rc 1/4, NPT 1/4 AT IDF IDU 24 40 50 IN IDF FS
200 Lower limit 100 100 Lower limit 0 0 10 20 30 40 0 10 20 30 40 0 Transfer speed [m/min] Transfer speed [m/min] RS2H63-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.2 = 0.1 1,000 900 800 700 600 500 400 300 200 100 0 1,000 900 800 700 600 500 400 300 200 100 0 Mass of transferred object m [kg] Mass of transferred object m [kg] 63 Operating range Upper limit
P = 41 58.5 3 3 2 2 P=41 68.5 34.5 48 68.5 P=41 1 1 Stations Stations 34.5 48 D side entry (LD) ( 261.5 with AMC810-14 installed) 216 with AMC610-10 installed D side U side D side U side 100 with AMC610-10 installed ( 105 with AMC810-14 installed) 100 with AMC610-10 installed 100 with AMC610-10 installed 100 with AMC610-10 installed 118 (135) 159(172.5) 159(172.5) 118 (135) ( 105 with
50 0 to 100 X X X X Conductive NBR 50 10 to 200 X X X X X Conductive silicon rubber The above table covers only general characteristics of subject rubber materials.
Material Number Description NBR VVQ4000-80A-1 10 Gasket r Option NBR VVQ4000-80A-2 10 Gasket t A C y For 1 station Nil W Standard Stainless steel VVQ4000-80A-4 10 Clip For 2 stations(3) (2) IP65 enclosure is dust Note) Spare parts consist of sets containing 10 pcs. each.
P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 CDRB1BW50 Series CRB1 Series CRB2 Single/Double type CDRB1BW63, 80, 100 Solid state switch for size 10 and 15 requires no switch block, therefore the unit part no. will be P611070-13.
P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 P211070-10 P211090-10 P211060-10 P211080-10 P211010-10 CDRB1BW50 Series CRB1 Series CRB2 Single/Double type CDRB1BW63, 80, 100 Solid state switch for size 10 and 15 requires no switch block, therefore the unit part no. will be P611070-13.
10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40, 50 2 x 4, 3.5 x 7, 4 x 10 10 to 16 (Thin section series) 2 to 8 10 to 16 20 to 32 40 to 50 4, 6 Nylon tube, 4, 6 Urethane tube Vacuum entry Thread dia.
(Example) SS3YJ7-20-03 . 1 set (manifold base) SYJ712-5LZ-01 . 2 sets (valve) SYJ700-10-1A . 1 set (blanking plate assembly) SS3YJ7-42R-03-01 . 1 set (manifold base) SYJ714R-5G . 2 sets (valve) SYJ700-10-2A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
m(kg) Load weight: m(kg) 160 600 600 140 500 500 125 400 400 300 300 200 200 100 100 100 500 400 300 200 100 500 400 300 200 Maximum speed: V(mm/s) Maximum speed: V(mm/s) 31
Model Auto switch mounting Cushion Bore size (mm) 20 25 32 40 20 25 32 40 Action Standard stroke (mm) Port size Lubrication Model Rubber Air 10-/21-CM2R20 10-/21-CM2R25 10-/21-CM2R32 10-/21-CM2R40 11-/22-CM2R20 11-/22-CM2R25 11-/22-CM2R32 11-/22-CM2R40 25, 50, 75, 100, 125, 150 1/8 Relief type Vacuum suction type 25, 50, 75,100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 1/4 Non-lube
(2) V = 400 mm/s Graph (1) V = 200 mm/s 20 50 CXSM CXSL CXSM CXSL 10 10 Weight m (kg) Weight m (kg) 32 32 25 25 1 1 20 20 0.6 10 20 30 40 50 100 5 0.6 10 20 30 40 50 100 5 Overhang l (mm) Overhang l (mm) Graph (4) V = 800 mm/s Graph (3) V = 600 mm/s 6 5 3 32 2 Weight m (kg) Weight m (kg) 32 25 25 1 1 20 20 CXSM CXSL CXSM CXSL 0.6 10 20 30 40 50 100 5 0.6 10 20 30 40 50 100 5 Overhang l (
10 to 32 Graph (3) V = 200 mm/s Graph (4) V = 400 mm/s 4 20 3 10 32 5 25 1 Weight m (kg) Weight m (kg) 32 20 25 0.5 1 20 15 0.5 15 10 CXSM CXSL CXSM CXSL 10 5 0.1 5 0.1 10 20 30 40 50 100 10 20 30 40 50 100 Overhang l (mm) Overhang l (mm) Graph (5) V = 600 mm/s Graph (6) V = 700 mm/s (800 mm/s for 10) 2 0.6 20 32 25 0.4 1 15 20 Weight m (kg) Weight m (kg) 0.5 15 0.2 10 10 CXSM CXSL CXSM
distance + Stroke L (mm) 10 100 Eccentric distance + Stroke L (mm) m l S l : Eccentric distance (mm) S: Stroke (mm) Allowable Kinetic Energy L Extension Locking, Without Cushion Retraction Locking, Without Cushion Pneumatic Circuit 200 200 Warning 1.
Unit 1 Disable Does not generate an error. -10..10 V -5..5 V -10..10 V Selects the analogue input range. (AXB: Cannot select -10..10 V/-5..5 V/ -20..20 mA) -20..20 mA (AXA) Sets the analogue input device range. 0..10 V 2 Analogue input range Channel 0..5 V 1..5 V (AXB) 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary. Sign & Magnitude Signed binary.
200 mm/s mm/s USB cable A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2CN Communication cable PC PC is prepared by customer) Refer to 8CN2TB/PC Power supply connector for usage.
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.
Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21
0 50 100 150 200 250 300 Flow rate L/min (ANR) Flow rate L/min (ANR) Condition: Inlet pressure 0.7 MPa Condition: Inlet pressure 0.5 MPa ARM11AA1-312 (One-touch fittings: IN 10, OUT 6) ARM11AA1-312-1 (One-touch fittings: IN 10, OUT 6) 0.35 0.7 0.6 0.30 Outlet pressure (MPa) Outlet pressure (MPa) 0.5 0.25 0.4 0.20 0.3 0.15 0.2 0.10 0.1 0.05 0 0.00 0 50 100 150 200 250 300 0 50 100 150 200
Detection nozzle: 1.5 Piping: F type: 4 x 2.5 tube 1 m, 3 m, 5 m Test conditions G, H type: 6 x 4 tube 1 m, 3 m, 5 m Supply pressure: 200 kPa ISA3-F ISA3-G Piping length: 1m, 3m, 5m Piping length: 1m, 3m, 5m : When the display value becomes 9 or lower, "0" is displayed. "0" and "10" are displayed near "10". This does not affect the performance.