Supply NC output NO output Exhaust of NC exhaust of NO Pilot tor NC Pilot for NO P A B R s z Y P A B R1 R2 z Y P A B EA EB PA PB 1 2 4 3 5 1 2 1 4 Table 7.2 Typical port identitications M O N O S T A B L E A N D B I S T A B L E Spring returned valves are monostable. They have a defined prefened position to which they automatically retum.
C D 15, 20 (mm) Applicable switch model Bore size (mm) D-A9 D-F9, D-A9W A B C D A B C D 15 56.5 17.5 76.5 21.5 72.5 60.5 87.5 67.5 20 39.5 19.5 23.5 83.5 35.5 71.5 Note 1) Auto switches cannot be installed in Area C in the case of 15.
16 47 125 15 340 1/2 77 140 12 20 16 55 160 20 375 3/4 94 159 12 24 20 60 109 Tie-rod Type Low Pressure Hydraulic Cylinder Double Acting/Double Rod Series CHAW Front flange type: CHAWF Width across flats G 4-FD 4-J 2-Rc P T T V V Cushion adjustment screw MM Width across flats G GA Air release GA M MM R (max.) d d W W D E E D FY B C MA a a FT MA B F NA NA F K A A K H + Stroke S + Stroke
Setting Position (mm) D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, A34 D-A44 D-B5 D-B6 D-H7l D-H7C D-G5NTL D-H7lW D-H7lF D-H7BAL D-B59W Bore size (mm) A B A B A B A B A B A B A B 20 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 25 56.0 31.5 50.0 25.5 55.0 30.5 51.5 27.0 53.5 29.0 53.0 28.5 49.5 25.0 32 59.5 36.5 53.5 30.5 58.0 35.5 55.0 32.5 57.0 34.0 56.5 33.5 53.0
-20 VEX5504 06 10 VEX57-10 12 14 20 VEX591978 Power Valve: Economy Valve Series VEX5 How to Order How to order pilot valves VEX5 1 06 2 E Z 5 1 B SF4 20 Option Economy valve Light/Surge voltage suppressor None Nil Bracket B G Pressure gauge Electrical entry Rated voltage Light/Surge voltage suppressor (Only with solenoid) Type (Ex.)
Connector location on U side (FU) 3.5 163 10.7 47 106 71.7 9 9 U side 27 Manual override n X 12 12 2 B 4 A 8 2 B 4 A A A B A B A B A B A B A 7 SMC SMC SMC SMC SMC SMC SMC A A A A A A A B B B 2 B 4 A Indicator light 6 2 B 4 A 5 L2 L1 2 B 4 A 4 B B 2 B 4 A 3 2 B 4 A 2 P = 25 2 B 4 A 1 50.5 44 X Stations 38 27 Connector location on D side (FD) 11.7 16.2 139.9 (Single) 43.2 49.7 D side 148.9
The Direct Operation is performed according to the parameters set in Step Data No. 20. (b) The Direct Operation starts when the register value of address D9100 is changed from "0h" to "0100h".
WW WW WA WB Piping port M5 x 0.8 Cover surface GC Piping port 3M5 x 0.8 MM NN GA GB C D FY FB 2-FC Mounting hole A FT NA NB B 0 -0.3 FX FZ F Head cover port location Axial direction (R) S + Stroke H Z + Stroke Bore size (mm) NN Z 16 10 15 15 18.3 15 20 17 8 8 5 5 6.5 6.5 11 11 M5 x 0.8 M4 x 0.7 D GC B F H MM GB GA C A 102.5 101.5 5.5 4.5 20 20 NB FB 17.5 19 28 28 NA S WW WA WB FC 5.5 5.5
D-F9BV 12 CL @ HS A B MLGC 16, 20, 25 CNA CB CV/MVG @ HS A B CXW CXS 32, 40 CXT MX (mm) MXU D-A90V D-A93V D-A96V D-F9NV, F9NWV D-F9PU, F9PWV D-F9BV, F9BWV Auto switch model MXS A B Hs A B Hs Symbol Standard stroke MXQ 12 16 20 25 32 40 19 21 24 26 29 32.5 4.5 4 7.5 9.5 9 11.5 5.5 6 10 11 12 16 17 19 22.5 24.5 27 30.5 0 0 3.5 5.5 5 7.5 1.5 2 6 7 8 12 MXF Bore size (mm) MXW MXP Long stroke
Applicable bore size d H B C D E1 C H NX B A L1 A1 U1 I-04A 40 69 22 24 55 M14 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-05A 50, 63 74 27 28 60 M18 x 1.5 15.5 20 12+0.070 0 16 0.1 0.3 I-08A 80 91 37 36 71 M22 x 1.5 22.5 26 18+0.070 0 28 0.1 0.3 I-10A 100 105 37 40 83 M26 x 1.5 24.5 28 20+0.084 0 30 0.1 0.3 NT-04 40 M14 x 1.5 8 22 25.4 21 NT-05 50, 63 M18 x 1.5 11 27 31.2 26 NT-08 80 M22 x 1.5
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
HS Auto switch 36 12 24.5 SMC SMC A 33 B Auto switch 49.5 A B G 1/2 (applicable cable O.D. 6.8 to 11.5) Proper auto switch mounting positions (mm) D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C8 D-C73C D-C80C D-G39 D-K39 D-A33, D-A34 D-A44 D-B5 D-B6 D-G5NTL D-H7F D-B59W Bore size (mm) A A B A A A A B A B B B B B 20 14 10 8.5 12 10.5 14 9 15 13 12 6.5 8.5 12 7 25 14.5 12.5 9.5 9 11 14.5 9.5 12.5 15.5 11.5
Enable Generates an error. 1 -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
Table 6.1-1 Specification of earth leakage breaker Model Rated current [A] Sensitivity of leak current [mA] HRS050-A-20-B-R 20 30 6.2 Option J [Automatic fluid filling] 6.2.1 Option J [Automatic fluid filling] This function is available for customers who selected automatic fluid filling.
Mounting Heights for Stroke End Detection 20 & 25 Proper auto switch mounting positions (mm) B D-F9 D-F9V D-F9W D-F9WV D-A9 D-A9V D-A9 D-F9 D-F9W D-F9BAL Bore size (mm) SMC D-A90 B 15 16 A 12 13 B 19 20 A 11 12 B 18 19 A 8 9 SMC D-A90 20 25 A Approx.
A B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.
A2 Bracket B (Part no.: ZS-46-A2) The bracket configuration allows for mounting in four orientations. 30 25 20 45 5.2 30 9.1 13.6 1.6 5.2 5.2 22 7.2 7.2 20 * When using the bracket B, install it by taking the dimensions of the piping part into consideration. 16 ZSE20(F)/ISE20 Series Dimensions Panel mount adapter ZSE20(F) ISE20 Option 2 B Panel mount adapter ( Part no.: ZS-46-B) 47.8 50.8
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. #40 9 Filter Rc3/8 20m FQ1011N-10-T020-B-X61 Note Note) The filter shown above cannot be directly connected to the thermo-chiller.
W .TOea TT XIUS ' Z ZZ l ~/ t ~ ~ 20 27 Y. 42 11 20 45 153 8 15 !
) 32 32 25 25 0.1 0.1 20 20 15 15 10 10 0.01 0.01 0 0 20 40 100 60 80 20 40 100 60 80 Overhang L (mm) Overhang L (mm) CXSJM CXSJL Graph V = over 400 mm/s; up to 50 mm stroke 13 CXSJM CXSJL Graph V = up to 400 mm/s; up to 50 mm stroke 12 1 1 Weight m (kg) Weight m (kg) 32 32 0.1 0.1 25 25 20 20 15 15 10 10 0.01 0 20 40 100 60 80 0.01 0 20 40 100 60 80 Overhang L (mm) Overhang L (mm) 5 Compact