-L2 0x0013 (19) 0 R ID ISE70G-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.

Type 40 Applicable solenoid valve SYJ514-SYJ514M-SYJ524-SYJ524M-How to Order SS3YJ5--40-05 -M5 R port 1/8 P port 1/8 P, R port thread type Stations A port size 02 : 20 2 stations : 20 stations Applicable blanking plate assembly SYJ500-10-3A Nil A A Rc G NPT NPTF M5 01 M5 x 0.8 1/8 F N T A port M5 x 0.8, 1/8 Note) For more than 9 stations, supply air to both sides of P port and exhaust air

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS090 Series 5-14 HRX-OM-T004 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-R028 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

E 3 Auto drain Additional symbol Port size 1 None With auto drain 0 Flow direction: left to right MR unit Flow direction: right to left 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Applicable model AMR3l00-02 to 03 AMR4l00-02 to 04 AMR5l00-04 to 06 AMR6l00-10 R 3 4 5 6 Body size 3 4 5 6 Adapter ass'y port size (2 pcs.)

Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.

For positive pressure 80 ISE 02 N M For vacuum/ compound pressure 80 ZSE 02 N M Option 3 Rated pressure range Operating Note) manual (Booklet) (CD-ROM) Operating Note) manual 80 80F Calibration certificate Calibration certificate 0 to 101 kPa 100 to 100 kPa Symbol Symbol (Booklet) (CD-ROM) K T R Nil Piping Y W R1/4 (M5 female threaded) Rear ported 02 Note) All texts in both English

7 82.1 Max. 10 60.9 28.1 [35.1] 53.4 12.7 42.1 32.6 M8 x 1 15.1 39.2 [46.2] Approx. 300 (Lead wire length) Pg7 73 [75.2] (2.3) 63.2 [65.4] 83 72.1 3 58.2 3 64.7 3 3 42.2 19.5 19.5 19.5 19.5 11 11 11 11 2-2.6 (For mounting) 2-2.6 (For mounting) 2-2.6 (For mounting) 20 20 20 2-2.6 (For mounting) (2.3) (2.3) 20 (2.3) 23 23 23 23 27 Refer to the page 91 for dimentions with connector cable. 28

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS Series 5-14 HRX-OM-M091 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRSH Series 5-14 HRX-OM-Q033 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

30 31 52 50 56 31 03 65 Response message (Slave to Master) STX Slave Address ACK Command Reading data ETX BCC 02 30 31 06 50 56 31 30 30 31 38 37 03 0F 5.5 Message configuration HRS100/150 Series 5-14 HRX-OM-S010 Chapter 5 Simple communication protocol function 5.6 BCC EXOR algorithm of all characters from STX to ETX is read with the check code for error detection.

Bonnet Common IN Individual IN Common IN Individual IN Polyacetal 2 Regulator Regulator ARM2500-A-02 ARM2500-B-02 ARM3000-A-03 ARM3000-B-03 9 1 Replacement Parts End plate R 10 1 Description Material Part no. End plate L 11 1 No.

32, 40, 50, 63 124 AS3000-03 3/8 810 12.3 810 12.3 221 AS4000-02 1/4 1,670 25.5 1,670 25.5 40, 50, 63 80, 100 214 AS4000-03 3/8 1,670 25.5 1,670 25.5 205 AS4000-04 1/2 1,670 25.5 1,670 25.5 242 AS5000-02 1/4 2,840 44 2,840 44 40, 50, 63 80, 100 233 AS5000-03 3/8 4,270 66 4,270 66 224 AS5000-04 1/2 4,270 66 4,270 66 AS4000 Note) Flow rate values are measured at 0.5 Mpa and 20C.

OUTPUT PRESS. 0.01 0.01 0.01 0.01 0.2MPa 0.2MPa 0.2MPa 0.2MPa IR3000 IR3000 IR3000 IR3000-02 02 02 02BG BG BG BG *** *** *** ***-*** *** *** *** Product code *** *** *** ***-*** *** *** *** Product number Max. supply pressure Set pressure range G G G G T T T To o o o MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN MADE IN JAPAN o Production lot no. Production lot no.

. -8No.PS-OMH0003-F Model Indication and How to Order For Air : I S E For Fluid : I S E Option Indications Pressure specification 70 0 to 1 MPa 02 43 M S 70 02 43 A 75H L M Pressure specification Option 2 75 0 to 10 MPa Nil No option 75H 0 to 15 MPa A Bracket : Mounting screws are not included.

AF-OMR0020-C PRODUCT NAME MIST SEPARATOR MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,R,Z)-A AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,R,W,Z)-A AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-A Contents Page 1. SAFETY INSTRUCTIONS 1-5 2. APPLICATION 6 3. SPECIFICATIONS 6 4. HOW TO ORDER 7 5. OPTIONAL BRACKET ASSEMBLY 8 6.

ALF400 ALT-9 1.17-11 Auto Feed Lube ALF400 to 900 Operating pressure range Tank and line pressure How to Order Auto Feed Lube ALF 40 02 0 Option Auto Feed Lube Port size Symbol Description Applicable model W/ bracket ALF400 to 600 B 02 03 04 06 10 12 14 20 4 1 Body size 8 3 AC 40 50 60 80 90 2 1 2 1 4 3 4 3 AV 1 1 2 1 1 1 2 2 1 4 1 AU 2 1 AF Thread Rc (PT) NPT G (PF) N F AR Note 1) Tank

Proper tightening torque Nm Connection thread size 7 to 9 NPT 1/16, NPT, R1/8 12 to 14 NPT, R1/4 22 to 24 NPT, R3/8 28 to 30 NPT, R1/2 2. When a fitting is over tightened, more of the sealant material is squeezed out. Remove the squeezed out sealant material. 3. When tightening is not sufficient, it will cause sealant failure or a loose fitting. 4.

SYJA524-01 SYJA712-01 SYJA722-01 SYJA714-01 SYJA714-02 0.76 0.69 0.69 0.66 0.63 0.64 0.51 0.42 0.34 0.33 0.45 0.48 2.5 2.4 2.7 2.6 2.3 2.3 0.77 0.72 0.71 0.74 0.70 0.68 0.43 0.38 0.32 0.31 0.21 0.31 2.8 2.7 2.9 3.0 2.8 2.7 N.C. N.O. Rc 1/8 Body ported 80 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 130 (Without subplate 80) N.C. Base mounted (with sub-plate) SYJA724-01 SYJA724-02 N.O.

SYJA524-01 SYJA712-01 SYJA722-01 SYJA714-01 SYJA714-02 0.76 0.69 0.69 0.66 0.63 0.64 0.51 0.42 0.34 0.33 0.45 0.48 2.5 2.4 2.7 2.6 2.3 2.3 0.77 0.72 0.71 0.74 0.70 0.68 0.43 0.38 0.32 0.31 0.21 0.31 2.8 2.7 2.9 3.0 2.8 2.7 N.C. N.O. 1/8 Body ported 61 1/8 1/4 1/8 1/4 M5 x 0.8 111 (Without subplate 61) N.C. Base mounted (with sub-plate) SYJA724-01 SYJA724-02 N.O.