Two switch spacers are included with the product with built-in magnet. 906 Rotary Actuator 11-CRA1-Z Dimensions: Basic Type, 11-CRA1S30 Size: 30 Single shaft Double shaft 75 10 8 6 0 0.2 8 (g6) 7.8 0 0.2 28 Auto switch 8 x M5 x 0.8 depth 6 (Opposite side 4 locations) 28 40 4 x 6 (Mounting hole) 9 16 0 0.1 8g6 9.2 14 3 M5 x 0.8 (Vacuum suction port) 0 0.025 3 2 x Cushion valve (Width across

tapped) l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 5 M4 x 0.7 2.5 7 M4 x 0.7 2.5 9.5 Top Mounting l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 4.8 M4 x 0.7 2.5 6 M4 x 0.7 2.5 6 Axial Mounting (Body tapped) l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 5 M4 x 0.7 2.5 6 M4 x 0.7 2.5 6 Operating Direction

MG Lateral Mounting (Body tapped) CX D-X Front Mounting l1 l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M4 x 0.7 2.5 12.7 9.4 20M5 x 0.8 5.1 15.6 11.2 M5 x 0.8 5.1 20.6 16.2 Data Vertical Mounting (Body tapped) l Model MXU6 MXU10 MXU16 Bolt Maximum tightening torque (Nm) M3 x 0.5 1.1 5 M4 x 0.7 2.5 7 M4 x 0.7 2.5 9.5 Top Mounting l Model MXU6 MXU10 MXU16 Bolt Maximum tightening

JAS Series How to Order Port size M3 M3 x 0.5 M5 M5 x 0.8 U10 10-32UNF JAS L E A 04 M5 JAS L E A S 04 01 Seal method Type L Elbow Nil Without sealant S With sealant Control type1 Port size E Meter-out S Meter-in 01 1/8 1 Meter-out and meter-in types can be visually identified by the color of the knob.

Auto switch Cylinder B Cylinder A CUJ cylinder Auto switch Magnetic substance Non-magnetic spacer of 2.5mm or more Without shielding plate d 10 L 6 8 Bore L d 19 6 19 6 19.5 6 The space can be reduced by attaching shielding plates (steel plates 0.2 to 0.3mm thick) to the sides of the cylinders facing each other.

hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90

No.SYJ300-OMU0003 -2- / *3) 1 1.5 *3)1 1 () No.SYJ300-OMU0003 -3- SYJ Series 3 / 1 DC () () () () EXH () () 4 No.SYJ300-OMU0003 SYJ Series 3 / ( ) 1 ( ),COMCOM 2 C-R () C-R Sol.1: DC 3% AC 8% Sol.2: (SSR)AC 1) (C-R) OFF 2) () 1.NPN 3) AC,, , SSR SSR 1) Sol.1: Sol.2: 2) ,1V + 2.NPN 5 No.SYJ300-OMU0003 SYJ Series 3 / 1 -10 1)M5 M3 1/4 0.4~0.5Nm M5 1/6~1/4 1~1.5Nm ()

Low speed air supply High speed air supply Pressure in the tank New New 20 9.2 4 AV2000-A Current model 30 13.1 7.4 Up to 50% shorter 40 19.2 12.2 50 (Port size 3/4) 34.8 22.6 AV2000-A New New Fill time 50 (Port size 1") 41.3 24.4 Current model For 1(P) R 2(A) Improved adjustability at low speed air supply Needle Valve Flow Rate Characteristics Inlet pressure: 0.5 MPa 400 Air flow rate [L/

Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI unit: torque = 1.5 Nm) 4 x M(Valve manifold: refer to valve manifold catalogue) OFF US1 is not present or is below the dropout level (< approx. 17 VDC). Refer to the product catalog or operation manual to obtain more detailed information about outline dimensions.

screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90 106 2 2.3 3.2 6 7

Operating direction: Right Operating direction: Left a b c d e f g Nil Reed switch L R Solid state switch S h Nil L R S Operating direction Left Right a b h g d c f e Note) Lead wire length symbols 0.5m .

L (Example) A93L 5m. Z (Example) F9NWZ Note) Solid state switches marked "" are produced upon receipt of order. Note) For cylinders with auto switches, the switches (already attached to mounting brackets) are packed together with the cylinder for shipment, but are not mounted on the cylinder.

3 P R V 1-1 IDF100150F 1 1 IDX-OM-U021 1 1-2 1-2-1 (C) 1-2-2 G 1-2-3 K 1.6MPa 1-2-4 P 1-2-5 R 30A (IDF100F, IDF125F, IDF150F) 30Ma 1-2-6 V ON 1.5 OFF 0.5 1-2-7 3 2 1 1-2 IDF100150F 1 2 IDX-OM-U021 1 1-3 A 3 300 A 1-3 IDF100150F 1 3 IDX-OM-U021 1 B V IDF100F V IDF125F V IDF150F B 1-3 IDF100150F 1 4 IDX-OM-U021 1 3.6 5.2 (IDF100F, 125F) R OFF 5.2 L1 L2 L3 M5

B V IDFA100F V IDFA125F V IDFA150F B IDFA100F150F 1 4 1.3 IDX-OM-U022 1. 3.7 5.2 (IDFA100F, 125F) R OFF 5.2 L1 L2 L3 1,2 3,4 5,6 M5 9.5mm 3.5mm 2 1 3 2 4 5 6 M3 6.5mm 1.25mm 2 L1,L2,L3 PE: L2 L3 PE L1 M4 9.5mm 5.5mm 2 IDFA100F150F 1 5 1.3 IDX-OM-U022 1. 5.2 3.7 5.2 (IDFA150F) R OFF L1 L2 L3 M5 9.5mm 3.5mm 2 L1,L2,L3 PE: L2 L3 PE L1 1,2 3,4 5,6 1 3 2 4 5 6

M5 M5 M5 1/61/4 11.5Nm ) Rc Rc Rc Rc Nm Rc1/8 79 Rc1/4 1214 Rc3/8 2224 6 VF1000-OMP0001 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 5 5 5 5 / / / / ( ( ( ( ) ) ) ) ( ( ( ( ) ) ) ) 3 5m 30 ( ) 1 ()ISO VG32 2 ()ISO VG32 7 VF1000-OMP0001 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 (E) (T) DIN (D) L (L) M (M) DC +DIN +-1 2 (G) A C S DIN

M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.

Bore size (mm) 2 Model Note) 10 16 20 25 32 10 ZCUKC ZCUKQ ZCDUKC ZCDUKQ M4 x 0.7 M5 x 0.8 M6 x 1.0 M8 x 1.25 M10 x 1.25 ZCUKD ZCUKR ZCDUKD ZCDUKR 16 20 25 32 U R Note) When using ZC(D)UK 10, use ZP02 to 08U-X11. Pad shape is flat only.