Series: 1 (VQZ1000), Configuration: 1 (2 Position Single), Seal Type: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector, w/Light & Surge Suppressor), Manual Override: B (Locking Slotted Style), IP65 Compliant: No, Port Size: C6 (ø6 One-touch Fitting)

Series: 1 (VQZ1000, Body Width 10mm), Actuation: 1 (2 Position Single), Body Type: 2 (Body Ported), Seal: 1 (Rubber Seal), Function: Standard (0.35W DC, AC), Coil Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire, Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: C6 (ø6 One-touch Fitting)

This is a legacy product, and replaced bySQ1141-5L1-C6, VALVE, SGL, N/PLUG-IN, VALVE, SQ1000 VALVE, SOL 4-WAY, UD, SQ1000 BUILT IN FITTING LESS THAN 1/4, .31766 lb, SeriesType of actuationSealModelFlow characteristics (1)Response time (ms) (2)Weight (g) 1 4/2 (P A/B)4 5 (A R1)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?bar)]bCvC [dm3/(s?

Stations: 2 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: TCN (AS-i 8 in/out - 31 Slave Modes - 1 Power Supply Systems, -COM), Number of Input Blocks: 1 (Input Block 1 pc.), Input Block: 3 [M8, 4 Inputs (3 Pins)]

Stations: 1 Station, Port Size: C6 (ø6 One-touch Fitting), Wiring Specification: +COM, Lead Wire Length: 1 (1.5m Cable), Option 1: None, Option 2: D (DIN Rail Mounting), Option 3: N (Name Plate), Option 4: None, Option 5: S (Built-in Silencer, Direct Exhaust), Option 6: None, CE Compliant: Q (CE Compliant)

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None), Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: N (None)

Stations: 1 Station, Port Size: C6 (ø6 One-touch Fitting), Kit Name: F (D-sub Connector 25 Pin), Electrical Entry: D Side, Cable Length: 1 (1.5m Cable 25 Pin), Option 1: D (DIN Rail Mounting)

Stations: 8 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 1 (Input Block 1 pc.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: N [NPN (-)], Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)

Stations: 8 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: ZENN (EtherNet/IP, -COM), Number of Input Blocks: 1 (Input Block 1 pc.), Input Block: 3 [M8, 4 Inputs (3 Pins)], Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: None, Option 2: S (Built-in Silencer, Direct Exhaust)

25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,

25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,

Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, .52359 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with air

Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, .44092 lb

, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,

or 2s can be chosen., Easy connection and removal of wiring., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, DB, IFW/PFW 1/4INCH NPT VERSION, .52359 lb

Stations: 4 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 2 (Input Block 2 pcs.), Input Block: 1 (M12, 2 Inputs), Input Block COM: N [NPN (-)], Option 1: None, Option 2: None, US Option: X160US (Preferred US Option)

Stations: 4 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 1 (M12, 2 Inputs), Input Block COM: N [NPN (-)], Option 1: N (Name Plate), Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)

Stations: 4 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 1 (M12, 2 Inputs), Input Block COM: PNP(+) or w/o SI/Input Block, Option 1: N (Name Plate), Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)

Stations: 6 Stations, Port Size: C6 (ø6 One-touch Fitting), SI Unit: QN (Device Net, -COM), Number of Input Blocks: 6 (Input Block 6 pcs.), Input Block: 1 (M12, 2 Inputs), Input Block COM: N [NPN (-)], Option 1: N (Name Plate), Option 2: S (Built-in Silencer, Direct Exhaust), US Option: X160US (Preferred US Option)