Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm Double solenoid part no. Socket only (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm Lead wire length Single/3 position part no. AXT661-12A AXT661-14A AXT661-14A-6 AXT661-14A-10 AXT661-14A-20 AXT661-14A-30 Lead wire length Single/3 position part no.
Terminal + Analog output Main Circuit Black OUT (White) GND terminal PSE Blue DC () (Black) ZSE4 ISE4 Shield wire ZSE5 ISE5 ZSE6 ISE6 ZSE3 ISE3 Dimensions GS PSE520-01, T01 PS 3000 59.5 ISA (55.5) 35 10 50 ZSE1 ISE1 33.5 M5 X 0.8 depth 5 ZSE2 ISE2 ZSP ISl 01: R(PT) 1/8 T01: NPTF 1/8 Width across flats 19 32 32 ZSM Protective tube (Resists bending) PFl IFl PSE520-02, T02 3000 61.5 (55.5) 35
Lead wire length Socket (3 pcs.) 300 mm 600 mm 1000 mm 2000 mm 3000 mm Note)AXT661-31A-, for 100/110 VAC. AXT661-34A-, for 200/220 VAC.
SY100-30-3AS Z Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage R 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Lead wire length U Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm For AC voltage valves there is no S option.
32 40 3000 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke specification (XB11) applies to the strokes exceeding 2000 mm.
(For metal seal) 2(B) port side : Yellow 2.2 18 A side pressure sensor Plug B side pressure sensor 3000 3000 71.1 66.1 (For F type: 62.3) (For E type: 60.2) 33.3 31.3 37 56.6 45.6 62.1 (For 3-position) 33 33 SY3000/5000/7000 Series Made to Order Please contact SMC for detailed dimensions, specifications, and lead times.
VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 VQZ200/300/1000/2000/3000 DC L,M L,M L,M L,M
Theoretical air consumption of compressed air piping Average theoretical air consumption of cylinders in a cycle/m. (1 cycle = SWITCH ON/SWITCH OFF) 20 20 1500 2000 3000 1500 2000 3000 Piping bore size[mm] 10 10 1000 1000 160 125 3 4 5 5 150 200 300 400 500 150 200 300 400 500 Air consumption Q [Nl/min.]
Lead wire length Internal circuits Model 3m (~9ft) 0.5m (~1 1/2ft) 53 (1.9) 10 (0.35) D-Y59A, Y69A, Y7P D-Y59A, Y69A 50 (1.8) 9 (0.3) D-Y59B, Y69B, Y7PV Dimensions (mm) DC (+) Brown [Red] 1in = 25.4mm D-Y59A, Y59B D-Y7P Mounting screw M2.5 x 4l Main switch circuit OUT Black [White] Slotted-head set screw 2.5 3.4 Indicator light 6.2 6.2 5 DC () Blue [Black] 29 (500) (3000) (5000) D-Y7P (V)
Recommended terminals NVFR 2000, 3000: 1.25-3, 1.25-35, '1.25Y-3N, 1.25Y-3S (1.25mm centers) (spade type, size 4, 22-16 AWG). . NVFR4000: 1.25-3.5M. 1.25Y-31. 1.25Y-3M. .
Acceleration [mm/s2] 0 250 1 500 2 1000 3 1500 4 2000 5 2500 6 3000 7 4000 8 5000 9 6000 10 7500 11 10 12 12500 13 15000 14 17500 15 20 Note) The factory default setting for the switch is No.0.
Movement mode Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position 0 1: Absolute 100 10 3000 3000 0 0 0 100 0 0 0.50 1 1: Absolute 100 100 3000 3000 0 0 0 100 0 0 0.50
psig (20.7 MPa) inlet 4000 27.6 3500 24.1 1/4-20 UNC Screw For Panel Mounting Delivery pressure (MPa) Delivery pressure (psig) 20.7 3000 Max. 0.25 (6.4) Panel Thickness 17.2 2500 2000 13.8 To 6.88 (174.7) 1500 10.3 1000 6.9 500 3.4 0.75 (19.1) 0.50 (12.7) 3.84 (97.5) Min. 1.50 (38.1) 0 0.0 0 1000 2000 3000 4000 5000 6000 Flow rate (slpm, N2) 3.25 (82.6) Clearance For Panel Mounting 2.12
Specifications AP3100 AP3102 AP3150 AP3157 AP3125 Select compatible materials of construction for the gas Operating Parameters Gas Vacuum to 3000 psig (20.7 MPa) 1) Vacuum to 1300 psig (9.0 MPa) Vacuum to 3000 psig (20.7 MPa) 1) Operating pressure Vacuum to 1300 psig (9.0 MPa) Proof pressure Burst pressure Ambient and operating temperature Cv 3) 4500 psig (31 MPa) 10 psig (69 MPa) -40 to
32 40 3000 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.
For long stroke operation involving vibration and impact, the use of side supports is recommended even if the spacing value is within the allowable limits shown in the graphs. 0 1000 2000 3000 4000 0 1000 2000 3000 4000 Support spacing l (mm) Support spacing l (mm) 2. Support brackets are not for mounting.
NCA Stroke Range DSeries Bore size (mm) Standard stroke (mm) Long stroke (mm) MY1B 10, 16, 20, 25, 32, 40, 50, 63, 80, 100 100 to 2000 2001 to 5000 (Up to 3000 for 10, 16) -X MY1M(W) 16, 20, 25, 32, 40, 50, 63 100 to 2000 2001 to 5000 (Up to 3000 for 16) MY1C(W) 16, 20, 25, 32, 40, 50, 63 100 to 2000 2001 to 5000 (Up to 3000 for 16) 20MY1H 16, 20, 25, 32, 40 50 to 600 601 to 1500 (Up to 1000
light 8 3.2 DC (+) Brown 2.6 2 4.6 4 2.7 4 2.8 Most sensitive position 6 2.8 22 500 (3000) 20 2.7 OUT Black 3.2 2.6 DC () Blue 9.5 6 Most sensitive position 22 500 (3000) 4 D-M9B, D-M9BV Precautions OUT (+) Brown Be sure to read before handling.
Magnetically coupled cylinders save space and have a wide range of applications. The NCY series can be used in many diverse environments, because there is no external leakage. The use of a linear guide makes loading and moments, directly on the cylinder possible. T-Slots on the mounting surfaces provides mounting freedom, and a variety of guides can be used to achieve the necessary accuracy
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, NCY2S GUIDED CYLINDER, ME, 40MM NCY2S DBL-ACT AUTO-SW, 37.91950 lb