SMC Corporation of America
Elite Part Number Search
Search Results "MGCLB20-250-R"

Power off is displayed when power is not supplied. 3 Power status Indicates the connection status of the PCNFC reader / writer. 4 R/W connection status R/W undetected: NFC reader / writer is not identified or USB is not connected.

A( ) A 24V 12V 100V SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 24V DC 12V DC 100V AC SOL SOL C(+) C ZNR Light DIN connector circuit with light AC circuit DC circuit 1 2 1 2 NL R R LED NL: Neon light R: Resistor LED: Emitting diode R: Resistor 4.3-2 Series VQ20/30 Manifold Caution Caution Valve Mounting How to Mount/Remove from DIN Rail After confirming the gasket is correctly placed under

2 r t i !4 y q e !3 o w u !0 !1 M: Rod end male thread Component Parts Replacement Parts: Seal Kit No. Description Material Note Bore size (mm) Kit no. Contents Cylinder tube Aluminum alloy Hard anodized 1 20 25 32 40 50 63 Piston Aluminum alloy Chromated CQ2B20-PS 2 Stainless steel CQ2B25-PS 20, 25 Piston rod 3 Set of nos. above !2, !3, !

1 r y o e t !2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 Built-in magnet Without magnet Single acting u i r y o e w i e u !0 Built-in magnet Without magnet Rod end male thread Component Parts Replacement Parts: Seal Kit (For double acting) Note No.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-12 Connection of RS-232C 3.3 Installation HRR Series 3-20 HRX-OM-X071 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

Construction q t e r w IN Description No.

Because pipe fittings are press-fit, they must be replaced together with the cover assembly. r Those with a bore of 50 or more cannot be disassembled.

R 140 140mm With front bumper H 160 160mm With rear bumper Cylinder stroke (mm) Refer to the maximum stroke table on page 2. Indicate in alphabetical order when 2 or more symbols are applicable.

Cylinder with Lock Series MNB Taper ring Steel ball P f R R High locking efficiency Improved locking efficiency, as well as stable locking and unlocking (unlocking pressure 0.25MPa. 0.05MPa compared to conventional P/A products) have been realized by arranging a large number of precision steel ball bearings in two circular rows.

Functional option With end lock (R) Axial piping (P) For details of adjuster and functional options, please refer to "Optional specifications" on page 46. IN OUT Theoretical Output Table The dual rod ensures an output twice that of existing cylinders.

Caution Standard stroke (mm) Note) Bore size (mm) 20 25 32 40 50 63 80 100 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 Note) Manufacture of intermediate strokes in 1 mm increments is possible. (Spacers are not used.)

) -4No.PF-OMM0004-D () * UL UL1310 2 UL1585 2 30[Vrms] 42.4[V ]2 UL , 100 () 0~90 3mPas3cP () <> -5No.PF-OMM0004-D * 16 FG (49N () M8 IN IN OUT OUT OUT OUT IN 40 -6No.PF-OMM0004-D * () 6 33 () () 10 m DC(-)() -7No.PF-OMM0004-D * () () CE -8No.PF-OMM0004-D * 3 2459 LCD * -9No.PF-OMM0004-D * , *PVC PVC PVC PVC PVC , -10No.PF-OMM0004-D -11No.PF-OMM0004-D N M8 M8 R

Multistage Ejector Series ZL112/212 Energy saving, large flow rate, 3 stage diffuser construction Series ZL112/212 Suction flow rate increased 250% and air consumption reduced 20% with 3 stage diffuser construction (Versus 1.3, one stage model) 1 stage performance Maximum suction flow rate l/min (ANR) Air consumption l/min (ANR) Vacuum pressure Q1 Q2 Q3 ZL112 100 200 ZL212 63 126 Q1 Q2 Q3

0.4 340 10 4.5 6 8 250 1.0 3 8 (10A) 340 0.4 10 10 1 2 (15A) 420 Note) Refer to Glossary on page 17-3-15 for details of max. operating pressure differential and max. system pressure.

6 q e r t !5 w !4 CUJ CU CQS CQM CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !0 u y RQ MU 32 to 50 With auto switch (Built-in magnet) !6 q e r t !5 i o !1 !3 !2 !7 w !4 D-X 20Data !0 u y Description No.

Therefore, supply pressure regulated by a built-in regulator e passes through the air supply solenoid valve q and is applied to the pilot chamber r. The pressure in the pilot chamber r increases and operates on the upper surface of the diaphragm t. As a result, the air supply valve y linked to the diaphragm t opens, and a portion of the supply pressure becomes output pressure.

137H-V KA00728 (V120) KA00815 (V85) KA00812 (V100) KA00813 (V120) KA00814 (V150) KA01800 (V175) KA00731 (V85) KA00727 (V100) KA00728 (V120) KA00729 (V150) KA00730 (V175) KA00470 (P28) AL-130H Differential pressure indicator Blanking cap q O-ring KA00244 (P42) KA00808 (P60) KA00810 (P90) KA00796 (P120) KA00717 (P28) KA00723 (P42) KA00733 (P60) KA00114 (P90) KA03498 (P120) AL-133H Element r