SMC Corporation of America
Elite Part Number Search
Search Results "LEY16C-250-R3C918"

Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w

Table Accuracy: High Precision, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable,

Table Accuracy: High Precision, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller

Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller

Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.22, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable, Actuator cable length(

Oscillation Angle A: 320°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 1.2, Size: 30, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable

Oscillation Angle A: 320°, Torque (Range)(N⋅m): 6 to Less than 10, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 6.6, Size: 50, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable

Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC

Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 3 (3), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable

Table Accuracy: Basic Type, Max. Rotating Torque: J (Basic, 6.6 N.m), Rotation Angle: 320°, Motor Cable Entry: Basic, Entry Right Side, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IP™), Mounting: 8 (DIN Rail)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB Standard Stroke Maximum stroke (mm) Standard stroke (mm) Note) Bore size (mm) MB1 20 1000 CA2 25 1500 25, 50, 75, 100, 125, 150 200, 250, 300 32 CS1 2000 40 2000 Made to Order Specifications (For details, refer to page 6-17-1.)

Adsorption surface size SP2330 SP2430 SP2530 SP2630 150 x 150 180 180 20 150 82.5 82.5 105 16 200 x 200 230 230 20 200 107.5 107.5 130 25 250 x 250 280 280 25 250 132.5 132.5 155 36 300 x 300 330 330 25 300 157.5 157.5 180 49 755 SP Series Made to Order Please contact SMC for detailed specifications, delivery and pricing.

to 250 X 50 EPR 20 to 150 X X X The above table covers only general characteristics of subject rubber materials.

, 300 10 50, 100, 150, 200, 250, 300, 350 400, 450, 500 15 1000 20 2000 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800 25 4000 32 5000 40 100, 150, 200, 250, 300, 350, 400, 450 500, 600, 700, 800, 900, 1000 50 6000 63 Note) Contact SMC if the maximum stroke will be exceeded.

Refer to pages starting with 181 for mounting. 30 95 B 100 95 8(4)-6.2 (160) () () 110 95 20 95 A (140) () () A B Stroke Model LG1H202PA-100-F LG1H202PA-200-F LG1H202PA-300-F LG1H202PA-400-F 100 200 300 400 50 150 250 70 170 270 Dimenstions inside ( ) are for a 100 mm stroke. Positioning Time Guide Positioning time Positioning time (sec.)

2 Stainless steel Return spring Black y Resin End plate Replacement Parts VFR210 VFR220 VFR230/240/250 Part no. No. Description Material Gasket Hexagon socket head screw Pilot valve assembly Sub-plate assembly NBR Steel AXT624-20-2 AXT624-26 (M3 x 31) AXT624-20-2 AXT624-26 (M3 x 31) AXT624-20-2 AXT624-26 (M3 x 31) Refer to How to Order Pilot Valve Assembly on page 3-5-10.

Speed (mm/s) 250 3.5 2.3 1.5 1.2 1.1 500 2.4 1.8 1.4 1.2 1.1 Values will vary slightly depending on the operating conditions. A B C D Non-standard Motors: The following motors will be mounted when a motor mounted type is specified.

Station 11 Station 23 630 390 Station 12 Station 24 410 Station 13 Flat ribbon cable kit (P kit), PC Wiring System compatible (J kit) For single wiring SSQ1000 P 40A 250 L Symbol (Dimension L) Station Station Symbol (Dimension L) 190 430 Station 2 Station 14 210 450 Station 3 Station 15 230 470 Station 4 Station 16 250 490 Station 5 Station 17 270 510 Station 6 Station 18 For double wiring

745 550 300 860 1650 2105 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B) 65 (2 1/2B) 630 920 37 750 24 317 795 600 300 880 1410 1865 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B) 65 (2 1/2B) 710 970 37 1000 24 394 795 600 300 880 1670 2125 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B) 65 (2 1/2B) 735 970 53 750 24 373 845 650 300 890 1420 1880 120 250 80 (3B) 100 (4B) 150 (6B) 65 (2 1/2B)