If the breaker with shorter operating time is connected, the customers equipment could be cut off due to the inrush current of the motor of this product. 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min 30s 20s Operating time 10s 5s MIN 2s 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 130 200 300 400 500 600700 1000 1500 2000 3000 4000 Current (% to the capacity of the main breaker of this

Signal Cable O.D. 6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -30No.EX-OMN0011-F (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500

Signal Cable O.D. 6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 24 VDC (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For control) 5 Gray : Not connected -36No.EX-OMO0030-E (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500

Cable colour: Signal Cable O.D. 6.6 mm 1 Brown: 24 VDC (For solenoid valve) Nominal cross section AWG22 2 White : 0 V (For solenoid valve) 3 Blue : 24 VDC (For control) Wire diameter (Including insulator) 1.65 mm 4 Black : 0 V (For control) 5 Gray : Not connected Min. bending radius (Fixed) 40 mm (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 7 Cable length (L) 7 1500

. -42No.EX-OMH0025-C Specification Specifications Common specifications Item Specifications Ambient temperature -10 to 50 oC 2 Ambient humidity 35 to 85%RH (No condensate) Storage temperature -20 to 60 oC Withstand voltage 1500 VAC applied 1 minute (Between external terminals and the case) Insulation resistance 500 VDC 10 M or more (Between external terminals and the case) Operating environment

Solenoid valve supply voltage 24 VDC +10%/-5% Output channels 16 outputs Output type Sink/NPN (positive common) Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 2.1 W or less (manufactured by SMC) Output when communication error occurs Clear Internal current consumption (Unit) 0.1 A or less EX120/121/122: IP20 EX124U/D: IP65 EX126D: IP67 Enclosure Withstand voltage 1500

Transmission speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 : Cable Type A specification Item Specification Impedance 135 to 165 Capacity 30 pF/m or less Loop resistance 110 /km Wire diameter 0.64 mm or more Core cross-section 0.34 mm2 or more Lower-level bus Item Specification Number of branches for input/output 4 branches (16 points

Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Cable length [m] 1200 1000 400 200 100 -19No.EX-OMN0028-B Setting and Adjustment Switch setting (1)Loosen the display cover screw (indicated by arrow). (2)Open the display cover using a flat head screwdriver, etc. (3)Set the switch using a small watchmaker's screwdriver with a thin blade, referring to the setting

10%/-5% Output channels 16 outputs 8 outputs Output type Sink/NPN (positive common) Connected load Solenoid valve with surge voltage suppressor of 24 VDC and 2.1W or less (manufactured by SMC) Output when communication error occurs HOLD/CLEAR (set using DIP switch) Internal current consumption (unit) 0.1 A or less Enclosure EX120/121/122: IP20 EX124U/D: IP65 Environment Withstand voltage 1500

GND terminal" Conduction between each input terminal and 12VDC or 24VDC terminal. power supply for sensor 12VDC 10%, 60 mA Preset output form Compare, hold, one-shot (fixed at 100 ms) Output method Individual 5 points output, binary code output Output time lag 5 ms or less (in normal output)/ 60ms or less (in binary output) Communication RS-232C Proof voltage Between case and AC line: 1500

Network length Communication speed [kbps] 9.6 19.2 45.45 93.75 187.5 Max. cable length [m] 1200 1000 Communication speed [kbps] 500 1500 3000 6000 12000 Max. cable length [m] 400 200 100 : Maximum cable length differs depending on the specifications of a cable. The above cable length is based on type A cable.

Also maximum response time of sensor for Hyrodless Monosashi-kun is maximum 1500 mm/sec (15Kcps) in cylinder speed. Reversed cylinder travelling direction 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Cylinder stroke A phase output pulse B phase output pulse Counter value 0 1 2 1 3 4 3 2 Input / Output Input / Output of Hyrodless Monosashi-kun is performed by connector came from sensor.

(Page 9) 6 Bushing (bearing) 1000 Lateral load applied to rod end {N} (fR)[N] 100 100 80 63 50 10 40 32 1 1900 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.

HRW015-H HRW030-H HRW002-H1 HRW008-H1 HRW015-H1 HRW030-H1 HRW002-H2 HRW008-H2 HRW015-H2 HRW030-H2 HRW002-HS HRW008-HS HRW015-HS HRW030-HS HRW002-H1S HRW008-H1S HRW015-H1S HRW030-H1S HRW002-H2S HRW008-H2S HRW015-H2S HRW030-H2S 4h 2h 1h 30min 20min 14min 10min 6min 4min 2min 1min MAX 30s 20s Operating Time 10s 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500 600 700 1000 1500

(Page 9) 6 Bushing (bearing) 1000 fR[N] 100 Lateral load applied to rod 100 80 63 10 50 end 40 1 0 500 1000 1500 Cylinder stroke [mm] Fig. 1 Allowable lateral load applied to rod end C a u t i o n Be certain to align the rod axis with the load and direction of movement when connecting.

Specifications 16 25 40 Fluid Air Proof pressure 1.2 MPa Max. operating pressure 0.8 MPa Min. operating pressure 0.1MPa +5 to +60 o Ambient and fluid C temperature (No freezing) Lubrication Not required (non-lube) 1000 or less +1.8 +1.8 0 0 2700 or less Stroke length tolerance +2.8 +2.8 1001 to max stroke 0 2701 to max stroke 0 Cushion Air cushion, Shock absorber Piston speed 100 to 1500

Fluid Air Proof pressure 0.8 MPa 0.7 MPa Max. operating pressure 1.2 MPa 1.05 MPa Min. operating pressure 0.15 MPa +5 to +60 o Ambient and fluid C temperature (No freezing) Lubrication Not required (non-lube) Allowable stroke length tolerance 1000 mm or less +1.8 0 , From 1001 mm +2.8 0 Cushion Rubber bumper Air cushion, shock absorber Piston speed 80 to 500 mm/s 80 to 1000 mm/s 80 to 1500

MAXIMUM APPLICABLE FLOW RATE AFM40-A 1500 MAXIMUM APPLICABLE FLOW RATE (ANR) 1000 AFM30-A 500 AFM20-A 0 0.0 0.2 0.4 0.6 0.8 1.0 Inlet pressure MPa 7. TROUBLESHOOTING Refer to 8. CONSTRUCTION / PARTS LIST (P10), 11. DISASSEMBLY DRAWING (P23). TROUBLE POSSIBLE CAUSE REMEDY DEMARCATION PHENOMENON 1. 1. Replace the element. Clog of the element. Large air resistance reduces flow rate.

Signal Cable O.D. 6 mm 1 Brown: 24 VDC (For control) Nominal cross section AWG22 2 White : 24 VDC (For solenoid valve) Wire diameter (Including insulator) 1.5 mm 3 Blue : 0 V (For control) Min. bending radius (Fixed) 40 mm 4 Black : 0 V (For solenoid valve) 5 Gray : Not connected -42No.EX-OMP0013-E (2) Cable with power supply connector (SPEEDCON) Part number: PCA-140180 4 Cable length (L) 4 1500

(0.0017 MPa) rise in delivery pressure per 100 psig (0.7 MPa) source pressure drop Bottom mount (Option: panel mount) 0.55 in3 (9 cm3) 3.6 lbs (1.63 kg) 5) Inboard leakage Outboard leakage Leak rate Across the seat leak Surface finish Bonnet port Supply pressure effect Installation Internal volume Mass 1) 14 to 194F (10 to 90C) for Vespel seat. 2) Tested with Helium gas inlet pressure 1500