The LECP6 controls NPN or PNP step motors.Motor controller: Step motor (servo/24 VDC), Servo motor (24 VDC)?
The LECP6 controls NPN or PNP step motors.Motor controller: Step motor (servo/24 VDC), Servo motor (24 VDC)?
The LECP6 controls NPN or PNP step motors.Motor controller: Step motor (servo/24 VDC), Servo motor (24 VDC)?
Settings1 Content 1 Control and input 24 VDC Class2, 2 A Power supply 24 VDC Class2, 2 A Output OFF Output is OFF. (default setting) DIN rail mounting (Not available for SY series valves. Refer to the SY catalogue.) (1)When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB2) before mounting, using 2-M4 x 6 screws.
. : : : : : : : : : : 24 VDC Class 2, 2 A Power supply for Output Power supply for Control/Input 24 VDC Class 2, 2 A Electrical ON OFF ON ON ON ON ON ON ON 192.168.1.254 ON/OFF ON ON ON ON ON ON ON ON DHCP mode 120 mA or less Internal current consumption (Power supply for Control/Input) ON/OFF OFF OFF OFF OFF OFF OFF OFF OFF Remote Control mode (2)Mount and tighten the end plate at one end
Control and input 24 VDC Class2, 2 A Power supply 24 VDC Class2, 2 A Output The following instructions must be followed during maintenance: Turn off the power supply Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance Otherwise an injury can result. 24 VDC, 1.0 W or less, DC General per output Output rating -10 to 50 oC (Max
Power supply for Control/Input 24 VDC Class 2, 2 A These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".
Orange Yellow Diagnostic output 24 Series CRQ2 Auto Switch Precautions 3 Be sure to read before handling. Operating Environment Maintenance Warning Warning 1. Never use in an atmosphere of explosive gases. 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected auto switch malfunction.
Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
-4 M4 x 0.7 x 41 VPA544 VP500-17-1 Series Thread type VP500-24-3 M5 x 0.8 x 50 3 5 7 P F N T VPA344 VPA544 VPA744 Rc G NPT NPTF VPA744 VP700-17-1 VP700-24-1 Caution Port size Mounting screw tightening torques VPA344 1/8 1/4 VPA544 1/4 3/8 VPA744 3/8 1/2 Symbol 1 2 M3: 0.6 Nm M4: 1.4 Nm M5: 2.9 Nm 5-3-26 3 Dimensions VPA4150-Bottom ported SA VA SA 4-Rc 1/8 pilot port (5-Rc 3/8, 1/2) 4-9 mounting
terminal DIN terminal VQ7 Conduit terminal with indicator light DL DIN terminal with indicator light Piping Option EVS 0 Bottom ported 1 Side ported Port size Rated voltage VFN 4 Without sub-plate Applicable valve model Port size 1 100 VAC, 50/60 Hz Symbol Option Without sub-plate VP454 2 200 VAC, 50/60 Hz 00 3 110 VAC, 50/60 Hz VP474 4 220 VAC, 50/60 Hz (10A) 3 8 (15A) 1 2 03 04 5 24
Series ID/IDW/IDA Heatless Air Dryers High Capacity Heatless Air Dryer Series IDA 73 86 114 170 205 295 409 591 818 1136 1909 2273 2955 4091 lbs Kg Weight 160 190 250 375 450 650 900 1300 1800 2500 4200 5000 6500 9000 A B C inch mm inch mm inch mm 610 610 711 787 813 838 1067 1168 1245 1524 1575 1575 1219 1575 24 24 28 31 32 33 42 46 49 60 62 62 48 62 711 864 813 940 914 1041 1143 1448 1524
Replace the element every 2 years or when the pressure drop becomes 0.1MPa, whichever comes first, to prevent damage to the element. 0.02 0.02 00 00 2000 4000 6000 50 100 150 200 Flow rate L/min (ANR) Flow rate L/min (ANR) AF20 Rc 1/4 AF50 Rc 1 0.10 0.10 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.7MPa P1 = 0.5MPa 0.08 0.08 P1 = 0.3MPa Pressure drop MPa Pressure drop MPa P1 = 0.3MPa P1 = 0.1MPa 0.06 0.06
H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24
N.C. 24 No.ZL3-OM00801-A 11. ,, 11.1 25 No.ZL3-OM00801-A 11.2 11.3 (V),0, Pmax () (P1 Q1 ) (Qmax) 0() , 1L ZL3H ,-90kPa ,4.0 ,Pmax Qmax , 26 No.ZL3-OM00801-A 12. 12.1 12.2 0 27 No.ZL3-OM00801-A 13.
Note2: For display, refer to "Display" ( page 24 ) in section "SI Unit" in this manual. 2. SI unit for VQC/S0700 series valves ( EX500-Q ) 1. SI unit for SV series valves ( EX500-S 01 ) The SI unit is the unit to communicate with GW unit in combination with manifold valve. It can be used with SV series valves, VQC series valves and S0700 series valves.
V DC, Detailed type: Without filter, Flow Rate(L/min): 150 (24 V DC at 0.25 MPa), Power Consumption(W): 80 (24 V DC at 0.25 MPa), Lead wire length(mm): 300
V DC, Detailed type: Without filter, Flow Rate(L/min): 150 (24 V DC at 0.25 MPa), Power Consumption(W): 80 (24 V DC at 0.25 MPa), Lead wire length(mm): 1,000
V DC, Detailed type: Without filter, Flow Rate(L/min): 150 (24 V DC at 0.25 MPa), Power Consumption(W): 40 (24 V DC at 0.25 MPa), Lead wire length(mm): 300
V DC, Detailed type: Without filter, Flow Rate(L/min): 150 (24 V DC at 0.25 MPa), Power Consumption(W): 40 (24 V DC at 0.25 MPa), Lead wire length(mm): 1,000