SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-R-P-N01-WA2"

Number of Ports: 2 Port, Piping Direct., Plunger Length: 0 (Side Ported, Long), Body Option: U (w/Bottom Mounting Thread), Port Size: N01 (NPT 1/8, Side Ported Only), Actuator Type: 32 (Push Button, Extended), Suffix: R (Red), Indicator: None

Number of Ports: 3 Port, Piping Direct., Plunger Length: 0 (Side Ported, Long), Body Option: U (w/Bottom Mounting Thread), Port Size: N01 (NPT 1/8, Side Ported Only), Actuator Type: 34 (Twist Selector, 2 Position), Suffix: R (Red), Indicator: None

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Connector Type: S (M12 Connector Type)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: K (w/Certificate)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: K (w/Certificate)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: K (w/Certificate)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: K (w/Certificate)

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Piping Specifications: N01 (NPT1/8 Piping Adapter, Side Ported), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8)

Rated Vacuum Range: F (-100.0 to 100.0 kPa), Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8)