SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-N01-S"

How to Order RE A B REC L 40 150 CA2Y Without auto switch CX L Y7BW S 40 150 CDA2Y With auto switch CY MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of auto switches Built-in magnet RHC Nil S 3 n 2 pcs. 1 pc. 3 pcs. n pcs.

Gasket To seal M5 thread Material: Nylon 66 GF 30% Material: PVC M-5G1 M-5GH Ml P.2.3-24 P.2.3-24 Hl Dl MS Tl 2.3-22 Series MS Barb fitting for soft nylon: MS-5AU-3, -4, -6 Effective area (mm2) Weight (g) D L Part No.

Centralized piping on right L R R L R L Slide table actuation direction Centralized piping on left R L L R R L Slide table actuation direction 4. Never disassemble the magnetic component parts (external slider, internal slider) of the actuator (cylinder). If will cause decline of the holding force, etc. 2.

V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [L] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Pressure switch Thermometer Pressure control equipment Control circuit Solenoid

distance [mm] wStatic Neutralization Range IZF10 IZF10-L 300 mm 300 mm 8 s 8 s 4 s 4 s 0 0 2 s 6 s 2 s 6 s 300 mm 300 mm 600 300 900 1200 600 300 900 1200 Installation distance [mm] Installation distance [mm] IZF10R (Air flow level: 4) IZF10R (Air flow level: 1) 300 mm 300 mm 6 s 2 s 8 s 6 s 4 s 2 s 8 s 0 0 4 s 300 mm 300 mm 600 300 900 1200 600 300 900 1200 Installation distance [mm] Installation

Applicable model: ASV310F, ASV410F, ASV510F Sealant Applicable model Symbol Sealant P Silencer and One-touch fittings are ASV120F/E220F Wihtout Type installed. With ASV310F/E410F/E510F S 1 2 Tee Elbow (1) P Flame resistant resin body as standard.

An appl i cat i on w hi ch has t he possi bi l i t y of havi ng negat i ve ef f ect s on peopl e, propert y, or ani m al s requi ri ng speci al saf et y anal ysi s. 2 H andl i ng precaut i ons CAU TI O N I f pow er t o t hi s product i s cut of f due t o a pow er f ai l ure, et c. w hen i t i s i n a cont rol l ed st at e, resi dual pressure w i l l be ret ai ned t em porari l y.

min 15/ 23 Rated fiow of option T1 8 L/min 16 Circulating Rated fiow of option T2 8 L/min 24 fluid system Flow display range9 L/min 5 to 40 Electric conductivity display range S/cm 0.1 to 48(For option -DM) Electric conductivity setting range S/cm 0.5 to 45(For option -DM) Particle filter nominal filtration rating10 m 5 Bypass valve10 Installed Tank capacity L Approx.5 Fluid outlet , fluid

Manual release N L Non-locking style Locking style Cylinder stroke (mm) (Refer to the standard stroke table on p.3.4-5.) Lock position H R W Applicable auto switches/Refer to p.5.3-2 for further information on auto switch.

Buffer Specifications Model MXS6 MXS8 MXS12 MXS16 MXS20 MXS25 6 8 12 16 20 25 Bore size (mm) Horizontal mounting 2-20 in/s (50~500 mm/s) 2-12 in/s (50~300 mm/s) Piston speed Buffer stroke (mm) 5 10 At 0mm stroke At max. stroke 0.67 1.12 2.25 2.92 3.82 4.72 Buffer stroke load (lbf) 1.35 1.80 2.92 3.82 5.62 6.52 Note) Refer to P. 14 for cautions on buffer.

CE1 CE2 Stroke Stroke Speed ML2B Space-saving has been realized by simple circuit Comparison to Shockless Transfer Systems C J G5-S Time Time Stroke CV P = 0.5 MPa, M = 100 N P = 0.3 MPa, M = 100 N M = 100 N M = 300 N V = 300 mm/s V = 100 mm/s Sine Cylinder Cushioning keep up with depth of orifice as sine function which change depend on stroke.

Switches P: Operating pressure (MPa) V: Speed (mm/s) Stroke (mm) Mode of operation (horizontal, inclined, vertical) Mode of operation Note 1) Vertical operation Inclined operation Horizontal operation Review of load weight and operating pressure W Lo Guide First tentative bore size determination F1 D 1.6 x P First tentative bore size determination F2 D 1.6 x P First tentative bore size

Controller Specifications (P.15) Voltage drop Temporary voltage drop in the power supply. Modify all parameters as appropriate and test the operation. Set the speed to be 1 mm/s or more for the pushing operation. 9.6 Step Data setup (P.39) 11.3 Pushing operation (P.46) Check that the parameter values are set correctly for a pushing operation in the Step Data.

Line No. 90 L Adapters Male to Female X2 S/S . P3, L10 X3 S/S . P3, L10 X4 S/S . P3, L10 RX3-2-3-2 S/S. P4, L12 RX3-1-1-1 S/S. P4, L12 M8-6x6-8 S/S . P20, L78 Y8 S/S . P4, L14 3/8BK-6 S/S . P18, L69 C1 S/S. P1, L1 C2 S/S. P1, L1 C3 S/S. P1, L1 C4 S/S. P1, L1 C6 S/S. P1, L1 RC3-1 S/S . P1, L2 T1 S/S . P1, L4 T2 S/S . P1, L4 T3 S/S . P1, L4 T4 S/S . P1, L4 T6 S/S . P1, L4 RT3-1-1 S/S .

(mm) Overhang L (mm) Graph V = up to 800 mm/s (up to 700 mm/s for 15, 20) 4 CXSJM CXSJL Graph V = up to 600 mm/s 3 CXSJM CXSJL 20 32 0.5 25 1 15 20 0.5 15 Weight m (kg) 10 0.1 10 0.1 6 6 10 20 30 40 50 100 5 10 20 30 40 50 100 5 Overhang L (mm) Overhang L (mm) Note) V = 700 mm/s for 15, 20. 4 Series CXSJ Horizontal Mounting V = up to 400 mm/s V= = up to 800 mm/s V = up to 400 mm/s V= =

Angle adjusting screw Angle adjusting screw Angle adjusting screw n o A R ti n 0 0 n c ot g 9 e 9 o l e y at ir ti y c d a a a io e d w g w ir n j n u y d y ti s ra e e g s ti k k u n n n g j ti of d g of s d a e u ir e e e e j d of c l g a g ti g o n n e n k A n l g n ra ra A e y n n w io io a y at at 9 ot ot 0 R R The rotation range under the adjustment of an angle at 60 is indicated

L Speed: V [mm/s] Calculation example) T1 to T4 can be calculated as follows. a1 a2 Time [s] T1 = V/a1 = 300/3000 = 0.1 [s], T3 = V/a2 = 300/3000 = 0.1 [s] T = T1 + T2 + T3 + T4 [s] T1 T2 T3 T4 L 0.5 V (T1 + T3) V T1: Acceleration time and T3: Deceleration T2 = L : Stroke [mm] time can be obtained by the following equation. 200 0.5 300 (0.1 + 0.1) 300 (Operating condition) V : Speed

T GE VA Rc(PT)P Rear cylinder port Effective thread length S + Stroke H ?

m P 0.1 x m + m P D 1.6 x D 5.0 x D 5.0 x m m mv P Pv m > mv P > Pv Determination of allowable load mass & pressure Inclined operation (Refer to page 1548