Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.

In-line Type Applicable tubing O.D. d Inch Size Metric Size Applicable tubing O.D. d Applicable tubing O.D. d Model Weight D1 D2 L1 L2 M1 L3 Max. Min. (g) Model Weight D1 D2 L1 L2 M1 L3 Max. Min.

Intrinsically Safe Valve 5 Port Solenoid Valve Series 53-SY5000/7000/9000 Body Ported Electrical Entry L and LL Hazardous Location Class I Division 1 Groups A, B, C, D Electrical Entry TT Hazardous Location Class I, II, III Division 1 Groups A, B, C, D, E, F, G Single Unit Warning Do not install in Zone 0 (as defined in IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009)

Dimensions H1 (Hexagon width across flats) Applicable tubing O.D. d H2 (Hexagon width across flats) L4 L3 L5 D1 L2 M M L1 Metric Size Inch Size L5 L5 L4 Max. L4 Max. Panel-cut dimensions Panel-cut dimensions L1 L2 L3 M d D1 H1 H2 L1 L2 L3 M D1 d H1 H2 Model Model Min. Max. Min. Max.

(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 ASG22F-M5 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 M5 x 0.8 6, 10, 16, 20 R1/8 20, 25, 32 R1/4 20, 25, 32, 40 R3/8 40, 50, 63 R1/2 63, 80, 100 Specifications Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1 MPa Min. operating pressure 0.1 MPa Ambient and fluid temperature 5 to 60C (No freezing) 10 turns (8 turns Note 1)) Number

Tokyo 105 JAPAN Te/:03-3502-2740 Fax:03-3508-2480 1st pnnhng February 1995.D-036,P-53{M) November 1997, 67 5(RP) SpeclilCatlons are subject to change without pnor notICe Printed In Smgapore and any obltgaltOn on the pa r1 01 the manifacture.

U S C E Padlock mounting position D C Padlock mounting position D SUP. SUP A B A B IN OUT IN OUT 2 1 3 EXH. EXH.

Applicable tubing O.D. d Weight (g) D1 39.2 M1 L3 12.9 M2 M1 12.9 L2 14.3 L4 12.9 L1 5.2 D2 39.2 L3 23.5 Weight (g) D1 10.0 L2 13.7 L1 5.2 Model Tubing O.D. d AQ240F-04-00 Model Tubing O.D. d AQ240F-04-04 6 4 9.3 5 4 9.3 AQ240F-06-00 AQ240F-06-06 13.7 13.7 15.4 6.2 13.7 26.7 40.7 8 10.0 14.7 6 11.6 6 6 11.6 6.2 40.7 AQ340F-06-00 AQ340F-06-06 13.7 19.5 13.7 13.7 6.3 44.8 31.7 13 19.6 11.8

connector) kit (Flat ribbon cable) 25 pins 26 pins IP40 compliant IP40 compliant FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3 Flat ribbon cable (26P) without cable Flat ribbon cable (26P) with 1.5 m cable Flat ribbon cable (26P) with 3.0 m cable Flat ribbon cable (26P) with 5.0 m cable D-sub connector (25P) without cable D-sub connector (25P) with 1.5 m cable D-sub connector (25P) with 3.0 m cable D-sub

IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 2 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part

Model Option 10-/21-AW20(K)-B 10-/21-AW30(K)-B 10-/21-AW40(K)-B 10-/21-AW40(K)-06-B 10-/21-AW60(K)-B Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS AW62P-270AS Note 2) Set nut AR23P-260S AR33P-260S AR43P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) Round type Note 3) 10: G49-4-01, 21: G49-4-01-MS-X3 0.02 to 0.2 MPa setting Note 1) Assembly of a bracket

IS1000-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Differential 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V 24 V Voltage (AC, DC) 50 mA 40 mA 20 mA 50 mA Max. current 1.2 ms Operating time 30 G Shock resistance JIS Symbol AMR5100 AMR4000 AMR3000 14-7-1 Series AMR3000 to 6000 How to Order E3 03 R S AMR 4 0 00 Adapter Assembly (Part

Note 4) When a regulator is not mounted on the manifold, use the following blank plate assembly (with mounting screws and O-ring) For ARM1000: Part no. 136114A For ARM2000: Part no. 136214A VBA VBAT AP100 ARM2000-4A2-01G Option / Pressure Gauge: G15-10-01 How to Order Symbol Individual IN Common IN G15 10 01 IN 1 Max. display pressure OUT IN 2 1 OUT 2 10 1.0 MPa Not able to set the pressure

Fieldbus interface connector layout BUS OUT/Port2: M12 4-pin socket, D-coded (SPEEDCON) No. Designation Description 1 TD+ Transmit Data + 2 RD+ Receive Data + 3 TDTransmit Data 4 RDReceive Data BUS IN/Port1: M12 4-pin socket, D-coded (SPEEDCON) No.

Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.

SUP. 3 1 2 3 1 2 3 1 2 E Padlock mounting position D C SUP J 2 2 x K A T IN OUT AA 3 L 2 x P1 (Port size) B V BB U Built-in silencer (Option) M (Width across flats) 3 N P2 (Port size) Q EXH Y Bracket (Option) R S X W Dimensions (mm) Standard specifications Model P1 P2 A B C D E F G H I J K L M 1/8, 1/4 1/4, 3/8 1/8 1/4 3/8 1/2 1/2 66.4 80.3 104.9 110.4 134.3 22.3 29.4 38.5 42 53 40 53 70

Free flow Controlled flow Model Port size Applicable cylinder bore size (mm) Effective area (mm2) Effective area (mm2) Flow rate (/min (ANR)) Flow rate (/min (ANR)) Weight (g) 4.7 AS1000-M3 M3 x 0.5 20 0.3 20 0.3 2.5, 4, 6 33 AS1000-M5 M5 x 0.8 90 1.4 80 1.2 6, 10, 16, 20, 25 90 AS2000-01 1/8 340 5.2 250 3.8 20, 25, 32, 40 115 AS2000-02 1/4 340 5.2 250 3.8 130 AS3000-02 1/4 810 12.3 810 12.3

ZH05DA06 06 06 One-touch One-touch One-touch 06 01 06 One-touch Screw-in One-touch 01 01 01 Screw-in Screw-in Screw-in ZH05DA07 07 07 One-touch One-touch One-touch 07 N01 07 One-touch Screw-in One-touch N01 N01 N01 Screw-in Screw-in Screw-in ZH07DA06 06 06 One-touch One-touch One-touch 06 01 06 One-touch Screw-in One-touch 01 01 01 Screw-in Screw-in Screw-in ZH07DA07 07

Panel mount adapter (Model: ZS-26-B) Panel mount adapter + Front protective cover (Model: ZS-26-01) 48 conversion adapter (Model: ZS-26-D) 2, Preparation of OUT1 device Prepare the sensor for which OUT1 is to be set. ON OFF Selection of Pressure range, Output style, Response time and Pressure setting method.

Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator