USB 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN4 CN3 CN2 CN1 DC24V AWG20(0.5mm 2) 8mm C24VM24VEMG DC24V OV UL ,UL1310 Class2 DC24V EMG C24V 24V 0V 0V M24V 5 -
1.2 (1) /CD-ROM (PDF) (2) ACT Controller Easy OK (3)JOG ON OK SVRE JOG OFF OK 6 -
ALARMReset Reset ) (4) /No.0No.1No.0 ON /(3)JOG
Move mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 Caution Writing of the step data should be performed while the electric actuator is stopped 59 - Details of step data Setting name Range Description No. 0 to 63 Number of the step data.
100 500 1 1 200 1000 200 1000 2 2 A-miniB type 50 200 50 200 3 3 CN2 CN2TB/PC 27 - 6.CN4 6.1 No.
300 500 75 110 Purge air flow rate L/min(ANR) 60 86 29 50 18 25 Inlet air pressure MPa Inlet air temperature oC Inlet air saturation temperature oC Ambient temperature oC *Note 1 *Note 1 -20 -15 -40 *Note 2 Standard performance conditions *Note 3 0.7 25 25 25 Dew point indicator purge air flow rate 1L/min (ANR) {In case of inlet air pressure 0.7 MPa} 1/4 3/8 Port size 0.78 (0.91) 0.81 (
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M min. between external terminals and F.E. Standard CE marking, UL (CSA), RoHS Weight 170 g 175 g 1: All unused connectors must have a seal cap fitted.
(No condensation) Withstand voltage 500 VAC for 1 minute between external terminals and F.E. Insulation resistance 500 VDC, 10 M or more between external terminals and F.E.
Assembly and disassembly of the SI unit -28No.EX-OMN0009-G Specifications Specifications General specifications Item Specifications Ambient temperature -10 to +50 oC Ambient humidity 35 to 85%RH (No condensate) Ambient temperature for storage -20 to +60 oC Withstand voltage 500 VAC applied for 1 minute Insulation resistance 500 VDC, 10 M or more Operating atmosphere No corrosive gas Enclosure
Failure of the power supply for the solenoid valve Check supply voltage of the solenoid valve power supply. -27No.EX-OME0014-F Specification Specifications General specification Item Specification Operating ambient temp. -10 to +50 oC Operating ambient humidity 35 to 85%RH (No dew condensation) Storage ambient temp. -20 to +60 oC Withstand voltage 500 VAC for 1 min.
C 10 500 30 20 400 300 200 100 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. Fig. 5-1 Cooling capacity *The Radiating water flow rate of 1L/min is for reference. Radiating water Temp.20 Ambient Temp.20 Fluid water 600 Cooling capacity W 500 Radiating water flow rate L/min 1 3 5 400 300 200 100 0 0 10 20 30 40 50 60 70 Recirculating fluid temp.
ZSE10 ZSE10F ISE10 (vacuum) (compound) (positive pressure) Rated pressure range 0.0 to -101.0 kPa -100.0 to 100.0 kPa -0.100 to 1.000 MPa Set pressure range 10.0 to -105.0 kPa -105.0 to 105.0 kPa -0.105 to 1.050 MPa Withstand pressure 500 kPa 500 kPa 1.5 MPa Minimum display unit 0.1 kPa 0.1 kPa 0.001 MPa Applicable fluid Air, inert gases and incombustible gases Power supply voltage 12 to
4000 Current (% to the capacity of the main breaker of this product) Figure 3-6 Breaker operating characteristics curve HRZ Series 3.3 Procedure for Installation 3-9 HRX-OM-I051 Chapter 3 Transporting and Installation HRZ008-L HRZ008-L1 4h 2h 1h 30min 20min 14min 10min 6min 4min MAX 2min 1min Operating time 30s 20s 10s 5s 2s MIN 1s 0.5s 0.2s 0.1s 0.05s 0.02s 0.01s 100 135 200 300 400 500
ZSE30A ZSE30AF ISE30A (vacuum) (compound) (positive pressure) Rated pressure range 0.0 to -101.0 kPa -100.0 to 100.0 kPa -0.100 to 1.000 MPa Set pressure range 10.0 to -105.0 kPa -105.0 to 105.0 kPa -0.105 to 1.050 MPa Withstand pressure 500 kPa 500 kPa 1.5 MPa Minimum display unit 0.1 kPa 0.1 kPa 0.001 MPa Applicable fluid Air, inert gases and incombustible gases Power supply voltage 12
How to Order Standard Elements 500 EM A 074 Element seal material/Operating temperature range Micromesh element symbol Symbol Element seal material Non-asbestos Fluororesin NBR FKM Operating temperature range(C) 0 to 150 0 to 120 0 to 80 0 to 120 Symbol Element composition symbol A Note) Element composition symbol Stainless steel 304 Stainless steel 316 T Note) 100 500 N V Note) Not possible
Auto switches are shipped together with the product but do not come assembled. 3 Compact Guide Cylinder MGPK Series Specifications Bore size [mm] 12 16 20 25 32 40 50 Action Double acting Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure 0.12 MPa 0.1 MPa Ambient and fluid temperatures 10 to 60C (No freezing) Piston speed1 50 to 500 mm/s Cushion Rubber
Built-in magnet for auto-switches CV MVGQ Maximum Driving Speed of Cylinders 1000 1000 900 900 Cylinder speed (mm/s) Cylinder speed (mm/s) 800 800 Load factor: 10% Load factor: 50% 700 700 600 600 500 500 400 400 300 300 200 200 100 100 0 12 16 20 25 32 40 50 63 80 100 0 SYJ3000 VZ3000 VZ5000 VF3000 Bore size (mm) Series Variations Bore size (mm) Standard stroke (mm) Applicable valve series
F E B C85 Without rod boot With rod boot Front Rear 20 25 32 40 50 63 80 100 112 118 120 132+l 140+l 142+l 6 7 7 8 9 9 11 14 5.5 5.5 6.6 6.6 9 11 11 14 28 32 38 46 58 70 82 100 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 Up to 350 Up to 200 40 44 53 61 76 92 104 128 CG1 Up to 400 Up to 300 Up to 450 Up to 300 138 (147) 159 (171) 159 (171) 193 (207) 196 (210) 158 (167) +l MB Up to 800 Up to 500
weight kg Load weight kg 80 80 B W 63 63 10 10 50 50 B: Retraction locking F: Extension locking 5 5 40 40 32 32 25 25 1 0.5MPa 0.4MPa 0.5MPa 0.4MPa 1 20 20 0.5 0.5 100 500 100 500 Maximum speed mm/s Maximum speed mm/s 29 Series CLQ Specific Product Precautions 2 Be sure to read before handling.
600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310-01 ARJF310F-01
For notes w and e, refer to the left. 4B/6B 870 M20 X l 500 AMD1000 w When the element has reached its replacement interval, replace it immediately with a new element.
Maintenance Caution Model Connection (Flange) 2B 8B C 2B/3B/4B 500 A 330 B 300 D 1070 E 1200 F 1290 G 20 H 720 M16 X l 400 Anchor bolt M20 X l 500 AMF800 AMF900 400 550 560 745 300 300 1070 1090 1230 1320 1335 1450 24 24 q It is not possible to indicate a definite replacement interval for the element because it varies with the odor concentration of the compressed air.