600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663] (179) Upstream pressure of valve P1 1.0 MPa
D (for PA3000 automatically operated type) Discharge rate 5 0.040 125 (cycles/min) = = Cycles per minute Discharge per cycle Reference life cycles 1 1 = x x Service life Cycles per minute 8 (Daily operating time) 60 1 1 100,000,000 = x x 60 8 125 1666 days = 17-5-145 6 Series PA/PAX/PB Precautions 5 Be sure to read before handling.
pressure P1 (MPa) IR IR2010-02 IR2010-02 IR2010-02 Supply pressure: 0.7 MPa Back pressure: 0.7 MPa 0.7 VEX 0.204 0.4 0.6 Set pressure P2 (MPa) Set pressure (MPa) Set pressure (MPa) AMR 0.202 0.5 Set point 0.3 ITV 0.4 0.200 0.2 0.3 IC 0.198 0.2 0.1 VBA 0.1 0.196 VE 0 100 200 300 400 500 0 0.2 0.1 0.3 0.4 0.6 0.5 0.8 0.7 0.9 0 100 200 300 400 500 600 700 800 900 1.0 Flow rate ( /min (ANR))
Rated pressure range Rated pressure range Rated pressure range Rated pressure range Rated pressure range 100 kPa to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa 101 kPa to 0 100 kPa to 100 kPa 0 to 100 kPa 0 to 1 MPa 101 kPa to 0 100 kPa to 100 kPa 0 to 1 MPa 0 to 2 kPa 101 kPa to 0 100 kPa to 100 kPa 0 to 500 kPa 0 to 1 MPa C O N T E N T S How to Order p. 7 Internal
consumption (W) Max. operating frequency (Hz) A 80 1200 B 40 1000 C 10 550 D 4 350 E Note) Two mounting screws (M3 x 0.5) and a gasket are included.
Remote sensor: [Nil] Integrated display type: [M] Integrated display type (IO-Link compatible): [M] Reference: 1 [L/min] 0.2642 [gal/min], 1 [gal/min] 3.785 [L/min] oF = 9/5 oC + 32 1: Made to Order. -16No.PF-OMW0004-B Manifold type B C S R Integrated type Integrated type Remote type Remote type (Basic type) (Straight type) (Supply type) (Return type) Main piping B/D/U D/U Open Close :
Vp-p, Pulse width: 1 m S, Start up: 1 nS Withstand voltage 1000 VAC(50/60 Hz) for 1 min. between lead wires and body Insulation resistance 2 M (at 500 VDC) between lead wires and body Vibration resistance 2 hrs. each in X, Y, Z directions at smaller of 10 to 500 Hz with amplitude 1.5 mm, or acceleration 10 G Impact resistance 100 G in X, Y, Z directions, 3 times each Note) Not available
M plug connector 2 position double: VZS2250-M(Z)-01 3 position closed center: VZS2350-M(Z)-01 3 position exhaust center: VZS2450-M(Z)-01 3 position pressure center: VZS2550-M(Z)-01 DIN terminal 2 position double: VZS2250-D(Z)-01 3 position closed center: VZS2350-D(Z)-01 3 position exhaust center: VZS2450-D(Z)-01 3 position pressure center: VZS2550-D(Z)-01 Applicable cable O.D.: 3.5 to 7 MAX
COM C COM C is receiving data: Lights up COM C is having no data to receive: Goes off COM D COM D is receiving data: Lights up COM D is having no data to receive: Goes off : It is lit when input unit is connected and communicating normally. 19 18 Display/ Switch Setting (continued) Switch setting Make sure that switch setting is performed with power supply turned off.
Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.
8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.
Auto switch Auto Switch Specifications D-M9N-5(With indicator light) Auto switch model D-M9N-5 Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less
D-M9N-5 ( ) D-M9N-5 3 NPN IC PLC DC51224V(4.528V) 10mA DC28V 40mA 10mA 0.8V (40mA 2V ) DC24V 100A ON CE RoHS D-M9N-5 M2.54L 15 - 5. 5-1. 1. () 2. 3. 4. 1. 5-2. 1. 2. 3. 4. Nm JMHZ2-16D M3x0.5 0.59 16 - M6x23 6.3Nm M4x10 1.0Nm 17 - P165-2. M3x7 0.59Nm 18 - (0.7mm) 19 - 5-3.
Correspondence between output data and valve manifold : Output numbers are assigned to stations from side D to U of manifold in order. (See manual of each valve manifold for the directions of side D and U) : Standard manifold is wired in double. Output numbers are assigned to side A and B alternatively. In case of single solenoid valve, output on side B is free.
TH0604N-500-X64 Made to Order Availability KQ2 Length Model Part no.
2 Air flow capacity (Series IDFS) Data D-1 Air flow capacity (Series IDUS) Model IDFS6E IDFS8E IDFS11E Model IDUS3E IDUS4E IDUS6E Air flow capacity (l/min (ANR)) Air flow capacity (l/min (ANR)) 740 1200 1650 310 500 740 Features 1 Stainless Steel Heat Exchanger Type Series IDUS 3E, 4E, 6E How to Order Voltage Model Options 3E 4E 6E 4 6 A C L IDUS M R Model Air compressor Refrigerant Voltage
Consult with SMC regarding water resistant types with the above model numbers. * Solid state auto switches marked with are produced upon receipt of order. ** Since D-A9and D-A9V cannot be mounted on 50, use of D-Z7 or D-Z80 is recommended. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ D* Since there are other applicable
D H1 KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R1/4 14 52 46 D H1 A L1 Reference dimensions after R thread installation Low noise nozzle with male thread: KNS [mm] Connection thread L1 A Width across flats Nozzle size Part no.
Baud rate Max. bus cable length 1 Mbit/s 25 m 800 kbit/s 50 m 500 kbit/s 100 m 250 kbit/s 250 m 125 kbit/s 500 m 50 kbit/s 1000 m 20 kbit/s 2000 m 10 kbit/s 5000 m -10No.EX-OMK0006-C Bus cable and termination resistors The cables, connectors, and termination resistors used in CANopen networks shall meet the requirements defined in ISO 11898.