Piston Material: Stainless Steel, Added Function: N/A, Rod Motion: Double Acting Single Rod, Operating Pressure Range(MPa): 0.3~13, Tube Material: Aluminum, Piston Speed(mm/sec): 8~100, Piston Packing Material: NBR, Stroke(mm): 20, Cushioning Mechanism: N/A, Operating Temperature Range(°C): -10~60, Support Type: Retainer Pin/Stopper Set, Standard: JIS Specifications, Nominal Pressure: 10MPa
Piston Material: Stainless Steel, Added Function: N/A, Rod Motion: Double Acting Single Rod, Operating Pressure Range(MPa): 0.3~13, Tube Material: Aluminum, Piston Speed(mm/sec): 8~100, Piston Packing Material: NBR, Stroke(mm): 20, Cushioning Mechanism: N/A, Operating Temperature Range(°C): -10~60, Support Type: Retainer Pin/Stopper Set, Standard: JIS Specifications, Nominal Pressure: 10MPa
IO-Link master unit (EX600-LAB1): 44 byte occupied Output date: (Unit 3) IO-Link maser unit (EX600-LBB1): 44 byte occupied Output date: (Unit 4) SI unit (EX600-SEN7): 4 byte occupied When Diagnostic mode 0 Input data Output data Byte 0 DXB (Unit 0) Input 0 to 7 Byte 0 DYB (Unit 1) Output 0 to 7 Byte 1 Byte 1 LAB1 (Unit 2) Process data : : LAB1 (Unit 2) Process data Byte 44 Byte 44 Byte 45
PF3A703H (For 3000 L/min) PF3A706H (For 6000 L/min) PF3A712H (For 12000 L/min) -95No.PF-OMX0002-B Dimensions Symbol Models A B D E F H K L N PF3A703H 130 45 79.1 55.3 22.5 25 35 60 30 4 x M4 x 0.7 depth 7 PF3A706H 170 60 94.1 70.3 30 68 45 80 40 4 x M5 x 0.8 depth 8 PF3A712H 200 70 104.1 80.3 35 85 50 100 50 4 x M6 x 1.0 depth 9 -96No.PF-OMX0002-B Lead wire with M12 connector (ZS-37-A) Pin
-62No.PF-OMW0004-B Integrated display type (straight type): PF3WC (mm) Flow range (L/min) a 0.5 to 4 (symbol 04) 40 2 to 16 (symbol 20) 40 5 to 40 (symbol 40) 45 -63No.PF-OMW0004-B Remote sensor type (supply type): PF3WS (mm) A B Flow range a (L/min) Open Close Open Close 0.5 to 4 (symbol 04) 33 14 33 14 40 2 to 16 (symbol 20) 33 14 33 14 40 5 to 40 (symbol 40) 33 14 33 14 45 -64No.PF-OMW0004
[oC]) PD = (Pr b) / a = [45 0] / 0.1 = 450 -76No.PF-OMV0006-B IO-Link parameter setting IODD file IODD (I/O Device Description) is a definition file which provides all properties and parameters required for establishing functions and communication of the device.
Weight*11 kg 45 *1 Use the product in conditions where freezing will not occur.
Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Reset . 48 . Operation Examples . 49 .. Positioning operation . 49 Operation Mechanism. 50 . Positioning operation . 50 . Return to the origin . 51 . Response time in receiving an electric actuator input signal 52 1 - . Methods of interrupting operation . 52 Alarm detection . 53 .
Operation Instructions . 45 .. Outline of operation command . 45 .. Positioning operation . 45 .. Pushing operation . 48 .. Reset . 51 . Operation Examples . 52 .. Positioning operation . 52 .. Pushing operation . 53 Operation Mechanism.54 1 - . Positioning operation . 54 . Pushing operation . 54 . Return to the origin . 56 .
Power supply connector . 42 6.1 Connector specifications . 42 (1) Motor drive power connector : M PWR . 42 (2) Control power supply connector: CI . 42 6.2 Wiring . 43 (1) Wiring of the power supply connector. 43 (2) Wiring of the stop switch . 43 (3) Wiring of the lock release . 44 6.3 Wiring of shutdown circuit . 45 (1) Stop (Stop switch) . 45 (2) Stop (Stop relay contact) . 45 (3) Motor
CN1 CN2 RJ-45 LEC-CAP-X22 27 - No a) RJ45 8P TM21P-88P HIROSE b) M12 4pin HR24-8DJ4PE550A(73) HIROSE XS2G-D4 [] c) M12 4pin HR24-8DP4S300(73) HIROSE XS2C-D4 [] 28 - 82 CN1 CN1 (LEC) 120 1/4W OV CN1 No.
degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig
Dimensions 45-47 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
Perations . 45 8.1 Return to origin position . 45 8.2 Positioning operation . 46 8.3 Pushing operation . 47 (1) Pushing operation is successfully performed . 47 (2) Pushing operation is failed (pushing the air) . 47 (3) Movement of the work piece after the completion of the pushing process . 47 8.4 Controller input signal response time. 48 8.5 Methods of interrupting operation . 48 2 - 9.
Vibration resistance: No malfunction occurred in a test ranging between 45 to 2000 Hz, when the actuator was tested in both an sending direction and a perpendicular direction to the belt. (The test was performed with the actuator in the initial state.) Note5) The power consumption ( including the driver ) is for when the actuator is operating.
Theoretical Output CE1 (N) Operating pressure (MPa) Bore size (mm) Piston area (mm2) 0.2 98 161 251 CE2 0.8 0.7 343 563 879 0.6 294 483 754 0.5 245 402 628 0.4 196 322 502 0.3 147 241 377 Stroke Adjusting Unit Specifications 25 32 40 490 804 1256 392 ML2B 643 25 RB1007 5.9 7 1500 70 4.22 6.86 32 RB1412 19.6 12 1500 45 6.86 15.98 40 RB1412 19.6 12 1500 45 6.86 15.98 5 to 60 Applicable bore
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states to the axis and right angle direction of the main valve and armature. (Value in the initial stage.) Note 2) At the rated voltage.
51.5 59.5 83.5 86.5 90 D-F7BA, F7lW, F7lF, J79W 8.5 17.5 21.5 43.5 48.5 46 41.5 48 56 80 83 86.5 D-F7lWV 5 14 18 40 45 42.5 39.5 46 54 78 81 40.5 D-A9ll 3 12 16 38 43 81.5 46 52.5 60.5 84.5 87.5 91 D-F7NT 9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16
A 1 2 150 165 42.7 76.3 45 65 40 60 35 40 80 80 ALBA90-10 ALBA90-20 1.17-24
and 2 tube gaskets. 1.7-27 Series MBlQ Basic/(B) G G Cushion valve W V Port 2-Rc(PT)P MM D E MB Effective thread 2 X 4-J lC lB MA A K F N N S + Stroke H ZZ + Stroke (mm) Stroke range Width across flats Bore (mm) Effective thread length A D Ee11 F N G P MA S MB V J W K H ZZ MM lC lB 32 40 50 63 80 100 22 30 35 35 40 40 46 52 65 75 95 114 32.5 38 46.5 56.5 72 89 12 16 20 20 25 30 30 35 40 45