Rubber bumper Nil Built-in magnet No Auto switch D With auto switch (Built-in magnet) Solid state M9B, M9BW, K59, K59W Reed switch A93, B54 Clean series Bore size (mm) Auto switch mounting method is band mounting only.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
Applicable models: D-A73, A73H, A73C, Z73, D-A93
AC DC Auto switch model Lead wire length (m) Load voltage Indicator light Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire Reed switch Solid state switch A96V A96 5 V IC circuit Grommet (NPN equivalent) Yes Yes Relay, PLC 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV
44.5 A 19.5 29.5 35.5 43 44 53 D 7.5 5 2 5 7 7.5 MY 6 10 15 20 25 32 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Note 1) 6: D-A90, D-A96, D-A93, D-F9BAL 10: D-A90, D-A96, D-A93 Only outward electrical entry (D dimension) is available.
V M9NA1 v v V v v IC circuit 3-wire (PNP) M9PA1 v v V v v 2-wire 12 V M9BA1 v v V v v 24 V Water resistant (2-color indicator) Grommet With diagnostic output (2-color indicator) 4-wire (NPN) 5 V, 12 V F59F V V v v IC circuit Magnetic field resistant (2-color indicator) 2-wire (Non-polar) P3DWA V V V v P4DW V V v Yes 3-wire (NPN equivalent) 5 V A96 V V IC circuit 100 V A93
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
A93 3m. L A93L Note) Refer to P. 177 to 179 for further information of auto switch. PLC: Programmable Logic Controller Specifications Specifications are same as the standard type.
NPN) F9NV F9N 3 wire(NPN) Diagnostic indication (2 color) F9PV F9P 3 wire(PNP) P.5.3-39 F9BV F9B 2 wire Relay, PLC 24V Yes Grommet 12V F9NWV F9NW 3 wire(NPN) F9PWV F9PW P.5.3-66 3 wire(PNP) F9BWV F9BW 2 wire PLC: Programmable Logic Controller *Lead wire length 0.5m (Ex.) 3m L A93 A93L Specifications Specifications are same as the standard style.
The series CU free mount cylinder saves space and allows direct and precise mounting. It is available in 6mm to 32mm bore sizes with stroke lengths up to 50mm. Options include auto-switch capabilities, free mount choices, recessed switch mounting grooves, non-rotating rod, double rod, single and double acting, and rubber bumpers standard. Free mount cylinder with air cushion, Bore sizes
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, COPPER FREE, ACTUATOR, CQS COMPACT CYLINDER, H6, 20MM CQS, .59840 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, COPPER FREE, ACTUATOR, CQS COMPACT CYLINDER, H6, 20MM CQS, .88184 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, COPPER FREE, ACTUATOR, CQS COMPACT CYLINDER, H6, 20MM CQS, .69947 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, EXCLUSIVE BODY, ACTUATOR, CQS COMPACT CYLINDER, HE, 20MM CQS DBL-ACT AUTO-SW, .98325 lb
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com CQS COMPACT CYLINDER. CYL, COMPACT, DBL ACT, AUTO-SW. ACTUATOR. 20MM CQS DBL-ACT AUTO-SW. .33197 lb. HE.
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches