Option (1) D C S Without option With locking mechanism With cancel cap With lever detection switch Action (2) D B T Double acting (1) The options can be combined, provided that the priority order is indicated as D, C, S.
Bracket C ZS-38-A3 Mounting screw (M3 x 5L, 2 pcs.) Panel mount adapter ZS-27-C Mounting screw (M3 x 8L, 2 pcs.) Panel mount adapter + Front protective cover ZS-27-D Mounting screw (M3 x 8L, 2 pcs.)
Response Status Check sum code Response data details + 3 3 3 3 3 3 + 1 1 1 1 1 1 2 2 2 2 2 2 C Preset value Allowance upper limit Allowance lower limit Output form (O/H/C) Writing preset data Command Block # 0 0 D W [CR] Unit No. Command Preset No.
AS ASP Pressure Valve: Series ASR Flow Valve: Series ASQ B Knob ASN Knob C Knob AQ D Knob ASV A E Knob AK Adjustment Procedure 2 ASS Pressure Adjustment Speed Control ASR 1. The cylinder speed is adjusted with knobs C , F and G . First have all the knobs fully closed and then open them gradually for adjustment.
Check the product for the following points before operation. a) Damage to power supply line and signal line. b) Looseness of the connector to each power line and signal line. c) Looseness of the actuator /cylinder and controller /driver mounting. d) Abnormal operation. e) Emergency stop of the total system. 3.
/B64 D-B59W D-G5BAL D-G59F D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C Auto switch model D-B7/B80 D-B73C D-B80C D-G79/K79 D-K79C D-H7C D-G5NTL D-G5W D-K59W D-G5BAL D-G5 D-K59 D-G5NTL D-H7W D-H7BAL D-H7 D-H7C/H7NF D-C7/C80 D-C73C D-C80C D-C73C D-C80C D-B5/B64 D-G59F D-B59W Applicable bore (mm) Hs Hs Hs A A A A A B B B B B B 16 (24) A 21.5 (29.5) 20.5 (28.5) 15.5 (22.5) 17.5 (25.5) 19.5 (27.5)
Reduced outgassing Resin materials eliminated Laser marking is employed for the model designation. o u d t g e 2 a c s u s d i Reduction of outgassing due to surface treatment e n o u d t g R e g a 1 c s u s d i e n R g All the external parts (made of aluminum alloy) such as the body and slide table are electroless nickel plated.
Note 2) Fixed unit: kPa ZY Vacuum pressure sensor ZF None Vacuum port adaptor Rc 1/8 Vacuum pressure gauge Digital pressure switch for vacuum Nil GN G D With digital vacuum pressure switch ZP Output specifications (Applicable only when the vacuum pressure sensor specification is D for digital pressure switch for vacuum) SP N P A B C D E F NPN open collector 1 output PNP open collector 1 output
C, prevent water droplets from entering the inlet port. (No freezing of the fluid) * Note 2. ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3.
C P P K K 8 U 57 (at knob locked) DIN rail part no.
MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Output specifications Symbol OUT1 OUT2 A NPN NPN B PNP PNP C NPN Analog (1 to 5 V) D NPN Analog (4 to 20 mA) E Note 2) PNP Analog (1 to 5 V) F Note 2) PNP Analog (4 to 20 mA) G Note 2) NPN External input Note 3) Unit specifications Nil Unit selection function Note 5) M SI unit only Note 6) Note 5) Since the unit for Japan is fixed to SI due to new measurement law, this option is for overseas
) 38L A B(ZS-46-A2) 38L B -15No.PS-OMU0005CN-C (a)(a) (b) (ZS-46-B) +(ZS-46-D) 90 -16No.PS-OMU0005CN-C (-M5) 1/6~1/4 1~1.5Nm (ZS-46-N) -01-N01 23 3~5 Nm -C4L-C6L 1/61/4 1~1.5Nm -17No.PS-OMU0005CN-C -18No.PS-OMU0005CN-C () TU0425( 42.5) -19No.PS-OMU0005CN-C FG -20No.PS-OMU0005CN-C Z/ISE20B(F)-S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max
C4L 4mm5/32 inch C6L 6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L 2 ) C ZS-38-A3 (M35 L 2 ) ZS-27-C (M38 L 2 ) + ZS-27-D (M38 L 2 ) ZS-38-3L 3 1 2m ZS-38-4L 4 2 2m ZS-38-3G 3 1 2m ZS-38-4G 4 2 2m ZS-38-5L 3 1m ZS-38-U
MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Note) X465 AMR Note) Except symbol G ITV IC Switch specifications Output specifications NPN output PNP output 1 to 5 V output 4 to 20 mA output Symbol A B C D VBA VE VY1 With digital pressure switch G PPA Note 1) Please contact SMC separately for details about the external dimensions, etc.
Add the bracket type C. B: Revision. C: Modified errors in text. D: Change of Limited warranty and Disclaimer. E: Contents are added. F: Measurement laws are added. G: Contents are added. H: Contents revised in several places. I: Contents revised in several places. [June 2018] J: Contents revised in several places.
Description ZS-28-A Note D Power supply/Output connection cable Mounting screw (M3 x 8L) (accessory) Bracket ZS-28-B With M3 x 5L (2 pcs.) Sensor connector ZS-28-C 1 pc. Panel mount adapter Panel mount adapter ZS-27-C With M3 x 8L (2 pcs.) ZS-27-D With M3 x 8L (2 pcs.)