200 mm/s mm/s USB cable A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2CN Communication cable PC PC is prepared by customer) Refer to 9.CN2TB/PC Power supply connector for usage.
They can be ordered in lots of 10 pieces. d D Series SY3000 SY5000 SY7000 Part No.
IODD file 1 D-MP025A/B/C SMC-D-MP025-ymmdd-IODD1.1 2 D-MP050A/B/C SMC-D-MP050-ymmdd-IODD1.1 3 D-MP100A/B/C SMC-D-MP100-ymmdd-IODD1.1 4 D-MP200A/B/C SMC-D-MP200-ymmdd-IODD1.1 : "ymmdd" indicates the file preparation date. y is the year, mm is the month and dd is the date.
200 mm/s mm/s USB cable A-miniB type 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2CN Communication cable PC PC is prepared by customer) Refer to 8CN2TB/PC Power supply connector for usage.
0.4 0.1 0.05 20 0 20 40 60 80 100 120 140 160 180 200 220 240 260 Operating temperature C How to Order 1.2 Metric size Max. operating pressure MPa D 20 TLM0425 N 1.0 0.8 E Tubing designation Length per roll Symbol 10 20 50 100 2S 0.6 F Type Length 10 m 20 m 50 m 100 m 2 m 0.4 Color indication G Roll Symbol N R BU B Color Translucent (Material color) Red (Translucent) Blue (Translucent) Black
Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V
Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]
(Values at the initial period) VG JIS Symbol VP S070 VQ Model Valve model VKF VS3145 VS3135 P A C [dm3(s
ZA A B t 2 x D ZX C ZM ZL ZH ZH ZH ZH -X267 ZH13 to 20DA 2 x D B ZHP A F E C ZU VQD-V Long clamping screw set for 1 station required for assembly needs to be ordered separately.
P I S T O N R O D A I R H Y D R O TYPE P I S T O N R O D D E F L E C T I O N (REFERENCE FACTOR) P I S T O N R O D D E F L E C T I O N (REFERENCE FACTOR) For a concentrated load at the center of the housing. For a concentrated load at the center of the end plate.
cable O.D. 6 to 8 (D, DL) Pilot port B (Air operated) L (Terminal with indicator light: DL) M (Conduit terminal: T) K (DIN terminal: D) I (Grommet: G) J (Conduit: C) 4 x 2-18 mounting hole Applicable flange Pilot port Rc A B C D E F G H I J K L M Model VNB5-32F VNB6-40F VNB7-50F 1 8 1 4 1 4 130 150 180 210.5 226 250 135 140 155 134 146 162.5 20 24 24 100 105 120 36 42 54 12 12 14 244 259.5
ZZ + Stroke Model B C D E(h8) I K L NA Q x R S TC x R W X ZZ REA50 REA63 0 86 32 53 30-0.033 32-0.039 58.2 25 110 55 M8 x 1.25 x 16 176 M12 x 1.25 x 7.5 60 60 180 100 38 66 72.2 26 122 69 0 M10 x 1.5 x 16 188 M14 x 1.5 x 11.5 70 70 192 Mounting nuts/2pcs. packaged with each cylinder d C H d B C Part No.
Auto switch model 2 (Same side) 2 (Different sides) 1 2 1 D-C7/C80 Band mounting style Rail mounting style 50 15 10 D-H7/H7W 60 15 10 D-H7NF D-C73C/C80C Note) Small round head screws 65 15 10 D-H7C Plate D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V D-J79C D-A79W/F7W D-J79W D-F7WV/F79F Solenoid valve 10 5 Pipe gasket 5 5 15 10 2.
A B C D E F Model no. A B C D E T Use 2 spanner flats when fixing the foot to the motor. Recom m ended setscrew: M6 4pcs. 4 Knock pin 2pcs. Use (1)(across flat) when fixing the foot at the rod. L[]ZB[]3 119.5+st 69.7+st 4 6.8 L[]ZB[]5 155.5+st 92.7+st 4 7 Model no.
Confirm the position where the pushing operation starts. a b c d e f g h i j k No.
Note) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) HRZ Specifications HRZD Model HRS090-Wl-20-l HRS090-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C 5 to
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com c B part e f d 2.
mounting style Rail mounting style 15 stroke 80 121 D-H7/H7W 15 60 10 30 stroke 88 140 Basic weight D-H7NF 45 stroke 98 164 D-C73C/C80C Note) 15 65 10 60 stroke 110 189 D-H7C Axial foot style 7 19 Mounting bracket weight D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V D-J79C D-A79W/F7W D-J79W D-F7WV/F79F 10 Rod side flange style 5 13 5 Mounting nut and rod end nut are included in the basic
(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)