SMC Corporation of America
Elite Part Number Search
Search Results "CDM2T32TN-100KZ-V"

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.213 lb

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic, foot, front and rear

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, LE, 32MM CM2 DBL-ACT AUTO-SW, 1.93193 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, HE, 20MM CM2 DBL-ACT AUTO-SW, 0.88184 lb

Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *,

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V]x1% = 0.04[V]) The maximum measuring range or change in analogue output over the maximum measurement range. F.S. (Full span, Full scale) H The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.

Description Part number Note 3 4 7, 13 4 7, 13 6, 12 8 9 14 V band for replacement O-ring O-ring O-ring O-ring Quick plug Upper element holder Lower element holder Intermediate holder FQ-BA001 JIS B2401-1A-P85 JIS B2401-1A-P11 JIS B2401-4D-P85 JIS B2401-4D-P11 KT-FQ1-N KT-FQ1-N FKM KT-FQ1-V KT-FQ1-V AG-9S Stainless steel 303 Stainless steel 304 Stainless steel 304 Stainless steel 304 AG-9S

Internal voltage drop: 1 V or less (With load current of 80 mA) PNP open collector Max. load current: 80 mA; Internal voltage drop: 1.5 V or less (With load current of 80 mA) Switch output Note 4) Output specifications NPN or PNP open collector Flow rate per pulse: 100 l/pulse, 10.0 ft3/pulse Pulse width: 50 msec Accumulated Note 4) pulse output Output voltage: 1 to 5 V; Load impedance:

Description Part number Note 3 4 7, 13 4 7, 13 6, 12 8 9 14 V band for replacement O-ring O-ring O-ring O-ring Quick plug Upper element holder Lower element holder Intermediate holder FQ-BA001 JIS B2401-1A-P85 JIS B2401-1A-P11 JIS B2401-4D-P85 JIS B2401-4D-P11 KT-FQ1-N KT-FQ1-N FKM KT-FQ1-V KT-FQ1-V AG-9S Stainless steel 303 Stainless steel 304 Stainless steel 304 Stainless steel 304 AG-9S

There is a danger of malfunction or damage to the reduced wiring system or input/output equipment. +24 V +24 V Power supply for output Power supply for output 0 V 0 V Power supply for control/input +24 V Power supply for control/input 24 V 4. Do not install a unit in a place where it can be used as a foothold.

Type V regulator (AR) is modified to produce the micro mist separator regulator (AWD).

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.

0 0 0 200 400 600 800 1000 1200 0 100 200 300 400 500 600 0 200 400 600 800 1000 1200 V (mm/s) V (mm/s) V(mm/s) LEFS16 LEFS25 LEFS32 50 12 B B 20 B A 10 A 40 H H A W(kg) W(kg) W(kg) 15 8 30 6 10 20 4 5 10 2 0 0 0 0 100 200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 V(mm/s) V (mm/s) V(mm/s) 10 - Step motor (servo 24VDC) Ball screw drive LEFS40 Model 150 to 1200 Stroke

The load doesnt work. < Auto switch operating range [mm] / Actuation operating speed [mm/s] -22No.D-S-OMJ0004-G Specifications D-M9B(E)(V)/D-M9N(E)(V)/D-M9P(E)(V) PLC: Programmable Logic Controller Switch part no.

To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.

To minimize the voltage drop, use 100/200 V AC and 24 V DC wires with the largest sectional areas possible and keep the wiring length as short as possible. 5. The 100/200 V AC wire must not be bundled with or arranged in close proximity with the input/output lines of control terminals or encoder signal lines. If possible, keep a 100 mm or larger distance from such lines. 6.

Float type auto drain AD44 Pressure gauge (V type only) Case assembly (N.O.)