Flame resistant style 1(P)/2(A): One-touch fitting Effective area Tube O.D (mm) Model (mm2) H L1 L2 L3 L4 L5 L6 L7 Q M1 M2 1(P)2(A) 2(A)3(R) 18 2(A) 4 1(P) 4 3.4 1.2 47.6 23.8 23.8 16.5 51.6 15.8 15.8 41 3.5 11 VHKlR-04F-04F VHKlR-06F-06F 18 6 6 41 48.6 24.3 24.3 16.5 3.5 52.6 11 16.8 16.8 7.2 1.2 VHKlR-08F-08F 18 8 8 41 52.4 26.2 26.2 16.5 3.5 56.4 11 18.7 18.7 9.7 1.2 VHKlR-10F-10F 22 10
(mm) Model Effective area (mm2) H L1 L2 L3 L4 L5 L6 L7 Q M1 M2 18 2(A) 4 1(P) 4 1(P) R 2(A) 2(A) R 3(R) VHK R-04F-04F 47.6 23.8 23.8 16.5 51.6 15.8 15.8 3.4 1.2 41 3.5 11 VHK R-06F-06F 18 6 6 41 48.6 24.3 24.3 16.5 3.5 52.6 11 16.8 16.8 7.2 1.2 VHK R-08F-08F 18 8 8 41 52.4 26.2 26.2 16.5 3.5 56.4 11 18.7 18.7 9.7 1.2 VHK R-10F-10F 22 10 10 46 61 30.5 30.5 21.5 4 65 14 20.8 20.8 16.1 3.2 VHK
See note 3 for other conditions. 10 Dimension between panels. Projection is not included. 11 Weight when the circulating fluid and facility water (for water-cooled type) is not included.
13 7 9 11.5 12 17 11.5 12 17 9 9 13 13 9 9 9.5 10 15 17.5 18 23 15 7 11 19 7 15 12 12.5 17.5 18 18.5 23.5 15.5 9.5 16.5 10.5 15 21 11 17 12 12.5 17.5 22.5 23 28 20 9.5 21 10.5 15 25.5 11 21.5 5.5 6 11 30.5 31 36 28 3 29 4 8.5 33.5 4.5 29.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.
-10 (FKM) 1.3 x 10-8 External 1.3 x 10-11 (FKM) 1.3 x 10-9 w, e w e Nil A B C P1 70W 1.3 x 10-8 1.3 x 10-11 (FKM) 1.3 x 10-9 Kalrez 1.3 x 10-10 (FKM) Q1 R1 R2 R3 S1 T1 4079 SS592 SS630 SSE38 1232-70 3310-75 Note 1) Values at ambient temperatures, excluding gas permeation.
L 10-1 . 10-1 10-2 . 10-1 10-3 . 10-2 11 M 11-1 . 11-1 11-2 . 11-2 11-3 . 11-2 11-4 . 11-2 12 R 12-1 . 12-1 12-2 . 12-1 12-3 . 12-2 12-4 . 12-2 12-5 . 12-2 13 T 13-1 . 13-1 13-2 . 13-1 13-3 . 13-1 13-4 . 13-2 13-5 . 13-2 13-6 . 13-3 14 14-1 . 14-1 2 IDX-OM-W026 i i i-1 () 3 i 1 1 3 IDF Series i-1 i-1 IDX-OM-W026 i i-2 5 i 2 1 IDF Series i-2 i-2 IDX-OM-W026
MU-C02 MU-C03 MU-C04 Pin material: Carbon steel +0.058 0 +0.058 0 +0.058 0 8 10 10 Knuckle pin is included in the double clevis and double knuckle joint as standard. C-type retaining ring for shaft is included. Rod End Nut CZ 8 10 10 CX 9 11 13 CT 9.5 11 14 CR 5.3 6.4 8.4 CL 26 42 54 Part no.
See note 3 for other conditions. 10 Dimension between panels. Projection is not included. 11 Weight when the circulating fluid and facility water (for water-cooled type) is not included.
(mm) IZN1007 (inch) 3.5 2 x M3 x 0.5 depth 10 26 32 7 25.8 Note 1) 11 Note 1) Dimensions of the resin part stated in Provide Grounding on page 454.
See note 3 for other conditions. 10 Dimension between panels. Projection is not included. 11 Weight when the circulating fluid and facility water (for water-cooled type) is not included.
11 100 20 25 98 28 57.5 89 26 17.5 depth 13.5 77 11 Rc3/8 112.5 100 M20 x 2.5 156 6.5 26 12 107 24 30 117 29 67.5 95 26 17.5 depth 13.5 94 11 Rc3/8 132.5 Rod end male threads (mm) H C D L K X Bore size (mm) 20 M8 x 1.25 15.5 10 23 8 18 32 M14 x 1.5 27 16 38.5 14 30 40 M14 x 1.5 27 16 38.5 14 30 M18 x 1.5 50 32 20 46 18 35 M18 x 1.5 63 32 20 46 18 35 M22 x 1.5 37 25 51 22 80 40 M26 x 1.5
HF10% or less 10 to 40oC Note 2) HF5% or less Hydrofluoric acid and Nitric acid mixture HNO35% or less Nitric acid HNO35% or less Hydrochloric acid HCl5% or less Copper sulfate solution H2SO496% or less 10 to 50oC note) HED007:10 to 30oC Note 2) Sulfuric acid H2SO496% or less 10 to 50oC note) HED007:10 to 30oC Note 2) Ozone 10 to 60oC Ammonium hydroxide NH35% or less 10 to 60oC Note
fluid fill set) To wastewater collection pit 11 Drain port No.
Option R . 10-1 10.1 SAFETY INSTRUCTIONS FOR USE . 10-1 10.2 EARTH LEAKAGE BREAKER SPECIFICATION . 10-1 10.3 CONNECTION OF POWER SUPPLY . 10-2 Chapter 11 Option T .11-1 11.1 SAFETY INSTRUCTIONS FOR USE . 11-1 11.2 OPERATION / ERROR SIGNAL OUTPUT . 11-1 11.3 REMOTE OPERATION . 11-2 11.4 CONNECT THE POWER CABLE AND SIGNAL CABLE . 11-3 11.5 ELECTRIC CIRCUIT . 11-4 Chapter 12 Option V . 12-1
Nylon Urethane KQ2W23-M5 30 8 31 10 M5 0.8 8 9.6 37 43 10 17.5 15.5 38 42 19 2.8 2.4 41 1 8 KQ2W23-01S KQ2W23-02S 10 14 3.2 1 4 KQ2W04-M5 KQ2W04-01S 8 18 30 37.5 32 38.5 M5 0.8 11 3.0 3.0 8 10.4 1 8 4 16 4.0 4.0 23 14 10 10 1 4 KQ2W04-02S 43.5 42.5 38 11 26 KQ2W06-M5 KQ2W06-01S 30.5 40 33.5 42.5 M5 0.8 8 3 3 8 1 8 10 6 17 12.8 20 1 4 10 KQ2W06-02S 46 46.5 17 14 10.9 10.9 41 3 8 KQ2W06-03S
to 10 (832) Integrated time setting; -10 to 10 (833) Differentiation time setting; -10 to 10 Table 12 Amount of change when set value is increased/ decreased by 1 Set value is 0 or more Set value is less than 0 Prop. gain 10% 10% Integ. time 50% 10% Deffer. time 10% 10% 8: When automation calibration is performed, PID constant is automatically set.
6 1000 20 5 100 30 4 10 50 6 1000 5 5 100 15 4 10 30 6 1000 20 5 100 50 4 10 60 6 1000 10 5 100 40 4 10 50 6 1000 50 5 100 80 4 10 100 LEFS16 500 500 LEFS25 900 500 Please aspirate it from the port on both sides when aspirating 50 /min(ANR).
T ype ;A .S C I ' D E F Y J ~ _L ~ " 4 15 9.5 14 4 4.5 6.5 7,5 ~ ZPlODQ Dl0 10 12 4 13 10,7 15 6 ::l 4 15 9.5 " ) L :l2 ~ 4 _'5 10 1~ ZP16DQ 016 16 18. '4 13, 11;.]11 1~ ,7 ZP4 ::l U40 4, 43 7 18 13.7 18.5 ZP25DO 025 25 28 4 15 15,5 20 10 I 0$0, I 50 53 7 18 14.7 ' 19.5 ZP40DO 0'\0 ,40 43 7 18 ~ "24.2 29 I .t~ lIE lndlcate malerlallo be selected at the end of part No.
set range LJ1 Nominal size: 16 Nominal size: 25 6 (10) kg 11 (20) kg 4 (5) kg 8 (10) kg 2.5 (2.5) kg 4 (5) kg 1.25 (1.25) kg 2.5 (2.5) kg Note 1), Note 2) Maximum load mass LG1 Acceleration and deceleration method Moving direction Both ends (Mechanical stoppers), 1 intermediate position Both ends (Mechanical stoppers), 3 intermediate positions 0.01 mm 0.1 mm 10 N 20 N Direct teaching,
Enable Generates an error. 1 Unit Disable Does not generate an error. -10..10 V -5..5 V -20..20 mA 0..10 V 2 Analogue input range Sets the analogue input device range. Selects the analogue input range. -10..10 V Channel 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary Offset binary.