In such places, use of antistatic fittings (Series KA) and antistatic tubing (Series TA) are recommended. 6. Do not use the ordinary fittings and tubing in locations where spatter is generated. Spattering may result in a fire hazard. In such a place, use of flame resistant fittings (Series KR/KRM) and flame resistant tubing (Series TRS/TRB) are recommended. 7.
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOG REFERENCE N301 1.14 LINEAR ACTUATORS: AIR CYLINDERS SERIES NCJ2 D I M E N S I O N S ( I N C H) N O N-R O TAT I N G S I N G L E A C T I N G S P R I N G E X T E N D B A S I C T Y P E NCJ2KB_-_T S Z 50 100 300 400 500 50 100 150 200 300 400 500 150 200 NB GA H KA Bore Size A BA BB CA CB F MM NN NA 1.92
RZQ R V Basic style (B): CG5BAS : With air cushion MI W S WA WB GA GB 2-P W 10 H1 Width across flats B1 CEP1 M BM CE1 Max.WH (E1) D CE2 B2 BZ MM AL A Plug bolt (4 pcs. included) ML2B K KA 8-J (F1) C 0.1 H S + Stroke ZZ + Stroke C J G5-S NA CV Stroke range A Bore size (mm) AL B1 B2 BM BZ C D E1 F1 GA GB H H1 I J K KA M MM NA P S MVGQ 20 Up to 350 18 15.5 13 7 M4 x 0.7 9 16.5 8 15 3 18 12
Y1 X1 Y4 Electromagnetic brake output ABS transfer mode Electromagnetic brake interlock (MBR) (f) Positioning completion To create the status information for positioning completion. During ABS data transfer (for several seconds after the servo-on (SON) is turned on), the servo motor must be at a stop.
T Note1) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com EB LL Concentrated piping on right (CY1F10 to 25R--) KA KB HW EW GD GC 2-P (Hexagon socket head plug) Hexagon socket head bolt For adjustment bolt fixing ES 2-P (Piping port) EY HA EH KC GB KH H GB GA GA G HB
X1 5 5 6 6 4 4 3 3 7 7 2 2 8 8 1 1 9 9 0 0 Set the units. (initial value: 1) Set the tens. (initial value: 0) 3 6 3. CC-LINK COMMUNICATION FUNCTIONS 3.2.4 Communication baud rate setting Set the transfer baud rate of CC-Link with the transfer baud rate switch (MODE) on the driver front. The initial value is set to 156kbps.
In such places, use of antistatic fittings (KA series) and antistatic tubing (TA series) are recommended. (3) Drain flushing (6) Do not use the ordinary fittings and tubing If condensate in the drain bowl is not emptied on a regular basis, the bowl will overflow and this may cause the malfunction of pneumatic equipment.
In such places, use of antistatic fittings (KA series) and antistatic tubing (TA series) are recommended. (6) Do not use the ordinary fittings and tubing in locations where spatter is generated. Spattering may result in a fire hazard.
This connection example complies with the requirement of ISO/EN ISO 13849-1 category 3 PL d. 24 V EMG S4 S3 KM1 S2 KM1 Fuse K3 +24 V XS0 XS1 Z00 Z10 Z20 KM1 Safety relay module MELSEC (QS90SR2S) Power supply Control circuit KM1 Driver Servo amplifier X0 COM0 24G X1 COM1 Z01 Z11 Z21 CN8 Control circuit STO1 S1 or EMG (Note) EMG STO2 STOCOM K3 TOFB1 TOFCOM 0 V TOFB2 20 S1: STO shut-off switch
Actuators Antistatic Air Cylinder (Made to Order) CM2-X1051 Vacuum Equipment Series KA Vacuum Pad Series ZP Fittings and Tubings Antistatic One-touch Fittings Series KA Miniature Fittings/Stainless Steel 316 Series MS Miniature Fittings Series M Antistatic Tubing Series TA Series TA Flow Control Equipment Antistatic Speed Controller (Made to Order) AS-X260 Front matter 16 Related Products
Air-hydro cylinder: CA1lHl-l, CQ2lHl-l, CS1lHl-l, CM2lHl-l, CG1lHl-l(to 63), HC03-X1-lXl Air-hydro rotary actuator: CRA1 Hl-l wWhen determining the size of a converter based on the
This connection example complies with the requirement of ISO/EN ISO 13849-1 category 3 PL d. 24 V EMG S4 S3 KM1 S2 KM1 Fuse K3 +24 V XS0 XS1 Z00 Z10 Z20 KM1 Safety relay module MELSEC (QS90SR2S) Pow er supply Control circuit KM1 Driver Servo amplifier X0 COM0 24G X1 COM1 Z01 Z11 Z21 CN8 Control circuit STO1 S1 or EMG (Note) EMG STO2 STOCOM K3 TOFB1 TOFCOM 0 V TOFB2 20 S1: STO shut-off sw
(b) Short-circuit current rating (SCCR) Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 kA rms Symmetrical Amperes, 500 Volts Maximum. App. 6 APPENDIX (c) Overload protection characteristics The LECSS2-T drivers have servo motor overload protective function. (It is set on the basis (full load current) of 120% rated current of the driver.)
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Cup Series: ZP (Basic), Cup Diameter: 25 (ø25), Cup Form: C (Flat with Rib), Cup Material: N (NBR), Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: C (PNP/with Unit Switching Function)
Unit Size: 75mm, Cup Flange Shape: with Flange, 42mm x 42mm, Cup Series: Basic, Cup Diameter: ø25, Cup Form: Flat with Rib, Cup Material: NBR, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: PNP/with Unit Switching Function
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Cup Series: without Cup, Cup Diameter: without Cup, Cup Form: without Cup, Cup Material: without Cup, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: A (NPN/SI Unit Only)
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Cup Series: without Cup, Cup Diameter: without Cup, Cup Form: without Cup, Cup Material: without Cup, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: B (NPN/with Unit Switching Function, Initial Value psi)
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Cup Series: without Cup, Cup Diameter: without Cup, Cup Form: without Cup, Cup Material: without Cup, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: C (PNP/with Unit Switching Function)
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Cup Series: without Cup, Cup Diameter: without Cup, Cup Form: without Cup, Cup Material: without Cup, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: D (PNP/SI Unit Only)
Unit Size: 7 (75mm), Cup Flange Shape: A (with Flange, 42mm x 42mm), Cup Series: without Cup, Cup Diameter: without Cup, Cup Form: without Cup, Cup Material: without Cup, Attachment: with (Guide) Attachment, Pressure Switch Output Spec/Unit: E (PNP/with Unit Switching Function, Initial Value psi)