Bore size (mm) 80 NLP-80A PDU-25Z PSD-33 x 25 P75 DSM-30 CA80-1609 CA80-1604 P5 Description Material No. 40 NLP-40A PDU-16Z PSD-22 x 16 P44 DSM-20 CA40-1606 CA40-1601 P3 50 NLP-50A PDU-20Z PSD-27 x 20 P50 DSM-25 CA63-1608 CA50-1602 P3 63 NLP-63A PDU-20Z PSD-27 x 20 P60 DSM-25 CA63-1608 CA63-1603 P3 100 NLP-100A PDU-30Z PSD-38 x 30 P90 DSM-35 CA100-1610 CA100-1605 P5 Piston seal Rod seal A
Description Material 40 NLP-40A PDU-16Z PSD-22 x 16 P44 DSM-20 CA40-1606 CA40-1601 P3 50 NLP-50A PDU-20Z PSD-27 x 20 P50 DSM-25 CA63-1608 CA50-1602 P3 63 NLP-63A PDU-20Z PSD-27 x 20 P60 DSM-25 CA63-1608 CA63-1603 P3 100 NLP-100A PDU-30Z PSD-38 x 30 P90 DSM-35 CA100-1610 CA100-1605 P5 Piston seal Rod seal A Rod seal B Brake piston seal Cushion seal Piston gasket Tube gasket Cushion valve seal
(Panel adaptor A + Panel adaptor B + Mounting bracket) ZS-22-D (With 4 pcs. of M3 tapping screws) ZS-22-E Panel adaptor A ZS-22-03 Panel adaptor B ZS-22-02 Mounting bracket ..
18 36 18.5 10 105 to 200 63 50 to 200 22 30 22 44 37.4 14 205 to 500 505 to 800 Material: Cast iron (Coating) The A and CL measurements are when the unit is in the Z-phase rst detecting position.
22 26 1/4 1/4 19 20.5 515 Series ARM11A/B End Block Pressure Gauge ARM11E L Part no.
Body Shim B Retaining ring 1 18 35 Tool steel Aluminum alloy Stainless steel t = 0.5 mm Guide pin Cylinder tube Magnet 2 19 36 Stainless steel Aluminum alloy Clamp arm Lock body Wear ring 3 20 37 Resin Aluminum alloy Structural steel Seat Intermediate collar Rod seal A 4 21 38 NBR Aluminum alloy Stainless steel Guide tube Lock ring Rod seal B 5 22 39 NBR Structural steel Tool steel Ring
L Dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ZK2 SE2 A 1 No.
L 21 22 23 24 25 26 27 28 29 30 273 285.5 298 310.5 323 335.5 348 360.5 373 385.5 No. L 31 32 33 34 35 36 37 38 39 40 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 No.
L-bracket 2.3 30 36 52 40 22 Straight type 3 m Cable connector TM-4DSX3HG4 50 Right angle type 3 m 4 x 5.5 8 x 4.5 4 x 7 22 TM-4DLX3HG4 50 36 40 84 40 36 22 40 5 36 7 4 x 5.5 8 x 4.5 22 14 20 60 70 12 1.6 14-8-15 16 Series ITV1000/2000/3000 Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF.
ZSP AWG24-26 (0.14 to 0.2 mm2) AWG24-26 (0.14 to 0.2 mm2) AWG20-22 (0.3 to 0.5 mm2) AWG20-22 (0.3 to 0.5 mm2) PSE510, PSE530 ZS-26-E ZS-26-E-1 ZS-26-E-2 ZS-26-E-3 ISA2 1.4 to 2.0 PSE521 1.0 to 1.4 IS PSE520 1.4 to 2.0 Refer to the following diagram for connecting Series PSE520 to the connector. ZSM PF2 Brown Black Blue N.C. 1 2 3 4 IF Data F.G.
POSITION TERMINAL STRIP 22 POSITION TERM P7=OUT 6 TERM P7=OUT 6 TERM P1=OUT 0 TERM P1=OUT 0 TERM P13=OUT 12 TERM P13=OUT 12 TERM P19=PE TERM P19=PE TERM P20=ITV +24 TERM P20=ITV +24 TERM P8=OUT 7 TERM P8=OUT 7 TERM P14=OUT 13 TERM P14=OUT 13 TERM P2=OUT 1 TERM P2=OUT 1 TERM P21=ITV_IN0 TERM P21=ITV_IN0 TERM P9=OUT 8 TERM P9=OUT 8 TERM P15=OUT 14 TERM P15=OUT 14 TERM P3=OUT 2 TERM P3=OUT
2.3 33 (8.5) 50 4 x 5.5 8 x 4.5 22 50 4 x 7 <36 40 84 40 36 22 40 5 36 7 4 x 5.5 8 x 4.5 22 14 20 60 70 12 1.6 Working Principle When the input signal rises, the air supply solenoid valve q turns ON, and the exhaust solenoid valve w turns OFF.
PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.
P3 P4 P3 P4 P1 P1 10[ms] 10[ms] -100 P2 P2 Disconnected Time ON-OFF output ON Time ON Normal mode OFF Operate in the manner same as ordinary since autoshift function is used. Time OFF Time Since autoshift signal is inputted at applying 50kPa, switching is done at pressures of 90[kPa] and 70[kPa].
(5) The release confirmation bit is set to 1 until the release pressure reaches P3 and then drops to P3-H3. -22No.EX-OMY0014-A 5. Process data 5.1. Process data on Vacuum / Release module The Vacuum / Release module occupies 2(4) bytes of input data and 2(4) bytes of output data. The number of occupied bytes differ by the selected head module.
Refer to Manifold option on page 22. Note2) When increasing over 4, 8, 12 manifold stations, exchange the Control Unit, Tension bolts, Protection plate and DIN rail for suitable parts for manifold stations. Refer to Replacement Parts on page 21. -23No. ZKJ-OM00201-D 8. Maintenance 8.1.
S1 S2 Preset pressure OFF OFF P1 ON OFF P2 OFF ON P3 ON ON P4 For safety reasons, it is recommended that one of the preset pressures be set to 0MPa. 1.12-16
Refer to "Connecting to other series" on page 22. Features 2 Pressure Sensor Series PSE530 How to Order PSE53 0 M5 Pressure sensing range High pressure [0 to 1MPa] Vacuum [0 to 101kPa] Low pressure [0 to 101kPa] Compound pressure [101 to 101kPa] 0 1 2 3 Option Without cable Nil Sensor cable (3m) M5 Port size L M5 Options Sensor cable (3m) + Connector (1 pc.)
An alarm code is assigned to both byte 21 and byte 22 in the response. 20 21 22 23 24 ALM_DATA 25 26 27 28 29 8.17.5 Write Non-volatile Parameter (PPRM_WR: 1CH) PPRM_WR Byte Description Command Response 17 1CH 1CH Writes the parameters.
L 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ITV NO.