(800) 526-7661 Parallel Run LTees 3/8 7/16 1/4 5/16 5/16 1/4 5/16 1/4 8 T1-L1-1 T4-L4-4 T3-L3-3 T2-L2-2 Parallel Run Reducing LTees 3/8 5/16 5/16 5/16 3/4 15/16 5/16 5/16 5/16 5/16 5/16 5/16 1/4 1/4 MEM 27/32 5/8 5/8 3/4 9 RT3-2L-2 RT3-2L-3 RT4-3L-4 RT1-3L-1 RT3-1L-1 RT2-3L-2 1 11/16 Crosses 1/2 15/16 5/16 5/16 11/16 15/16 MEM 1/4 27/32 1 1 33/64 5/8 15/16 3/8 11/16 1 1/8 1/4 5/8 27/32

Option Note ZS-38-A1 ZS-38-A2 ZS-38-A3 ZS-27-C ZS-27-D ZS-27-01 ZS-38-3L ZS-38-4L ZS-38-3G ZS-38-4G ZS-38-5L ZS-38-U ZS-38-C4H ZS-38-C6H ZS-38-N7H ZS-38-C4L ZS-38-C6L ZS-38-N7L Bracket A Bracket B Bracket C Panel mount adapter Lead wire with connector (with connector cover) Lead wire with a connector for copying Lead wire unit with a connector for copying One-touch fittings 4 mm straight

C85 Series CY1B Series REA C95 Bolt fixed from the upside CP95 Herisert tapped NCM F Note 1) For 6, 10 (CY1B) NCA R Note 2) Bolt fixed from the underside: MD D-X 20Body For 6, 10 (CY1B) Data F (1) MM LA R (2) L PA C HB M B HA W MD A Bore size (mm) 6 10 15 20 25 32 40 50 63 M3 x 0.5 x 3l 15 35 12 11 17 6.3 18 10 2.5 M3 x 0.5 x 3l 18 38 17 15 25 9.5 26 10 2.5 25 57 25 6.5 23 4 35 16.5

CY3B series REA series Bolt fixed from the upside Herisert tapped F Note 1) R Note 2) For 6, 10 Bolt fixed from the underside: MD Body For 6, 10 B F (1) A C HA HB L LA MM MD M PA R (2) W Bore size (mm) 6 10 15 20 25 32 40 50 63 10 17 2.5 6.3 11 35 15 M3 x 0.5 x 3L 12 18 10 25 2.5 9.5 15 38 18 M3 x 0.5 x 3L 17 26 16 35 5.5 16.5 23 57 25 25 36 M4 x 0.7 6.5 M3 4 6 18 36 5.5 17 23.5 66 30 27

temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 8 L/min Approx.900W(water), 600W(Fluorinert FC-77) Heating capacity Conditions: set temp. 25C, ambient temp. 25C, radiating water temp. 20C, radiating water flow rate 8 L/min Recirculating fluid : Water, Fluorine solvent(GALDEN HT-135 Fluorinert FC-77, FC-3283) Recirculating fluid Reservoir capacity : Approx.3L

Construction/Dimensions (mm) R Note 2) F Note 1) PA M MD MM LA L C HB B HA W Model A CY1B 6 12 M3 x 0.5 x 3l 15 17 6.3 11 35 18 10 2.5 CY1B10 17 M3 x 0.5 x 3l 15 38 18 25 9.5 26 10 2.5 CY1B15 4 25 M3 57 25 M4 x 0.7 6.5 23 16 35 5.5 16.5 6 36 CY1B20 27 4 30 M4 x 0.7 M3 66 18 36 6.5 5.5 17 23.5 6 37 CY1B25 36 M5 x 0.8 M4 5 30 46 8.0 21 28.5 70 47 20 5.5 7 CY1B32 M5 6 47 M6 x 1.0 9.5

Or for applications in which a pneumatic speed controller suffices (3l/min).

0.2% of full span Repeatability Within 0.5% of full span Linearity Within 1% of full span Note 3) Bleed port: 9.5l/min (ANR) or less (supply pressure: 1.0MPa) Exhaust port: 2l/min (ANR) or less (at maximum set pressure) Bleed port: 9.5l/min (ANR) or less (supply pressure: 1.0MPa) Exhaust port: 2l/min (ANR) or less (at maximum set pressure) 4l/min (ANR) or less (supply pressure: 1.0MPa) 3l

hlog l{0, u'lodel) A A, I D t l H K (tR)Otlll l.5ilr I 144 162 5l |il4z x 1.5 t3 38 44 9Z 46 'Jl 32 (1Rl0tl,ll.5lllx2 r95 213 5t M42 x 1.5 t3 38 44 E 59 3l 45 0 tl.5tlx3 246 ?64 5l M4? x 1.5 l3 38 44 143 37 (LR)0Iil2.0llx2 226 243 t3 M64x2 t9 50 57 140 70 48 50 0Ifi2.0Sx4 328 345 1164 x 2 t9 50 57 l9l 96 48 t6 0t 2.0tlxd 456 413 73 M 6 4 x ?

Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 piping adapter ZS-46-N1 NPT1/8 piping adapter ZS-46-N2 7

+0.1MPa Note 2) Air is always bleeding to atmosphere Regulating 3000: 0.01~0.2MPa 0.005~0.8MPa 0.01~0.8MPa Pressure 3010: 0.01~0.4MPa Range 3020: 0.01~0.8MPa Sensitivity 0.2% FS Max H O W T O O R D E R P R E C I S I O N R E G U L AT O R S E R I E S IR1/2/3000 Repeatability +0.5% FS Max Air Supply Pressure at 1MPa <9.5l/min (Bleed P) <4l/min <9.5l/min Consumption at 0.7MPa <2l/min (EXH) <3l

+0.1MPa Note 2) Air is always bleeding to atmosphere Regulating 3000: 0.01~0.2MPa 0.005~0.8MPa 0.01~0.8MPa Pressure 3010: 0.01~0.4MPa Range 3020: 0.01~0.8MPa Sensitivity 0.2% FS Max H O W T O O R D E R P R E C I S I O N R E G U L AT O R S E R I E S IR1/2/3000 Repeatability +0.5% FS Max Air Supply Pressure at 1MPa <9.5l/min (Bleed P) <4l/min <9.5l/min Consumption at 0.7MPa <2l/min (EXH) <3l

Response time Liie VOZ]000I0 rns -l VOZ2000 l2 ms 1 200 rfillion VoZsooo ls ms -l cYcres DIN rail mounting 3 Port Solenoid Valve Metal Seal/Rubber Seal 5 Port Solenoid Valve Metal Slsal/Rubber Seal Base Mounted Up to 063 0 . 1 7 0 3 3 0.39 0 4 5 o.3l 0 r 0 0 4 5 0.56 N C Vdlve Base Mounted N C .

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2 (Refresh), Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: G [Grommet (Lead Wire Length 300mm)], Surge Suppressor: S (w/

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 160, Flange Type: D [K (DN)], Valve Direction: G (w/Indicator, Rear Flange Surface), Version: Legacy, Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light & Surge

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 63, Flange Type: D [K (DN)], Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2 (Refresh), Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: L (L Type Plug Connector), Surge Suppressor: Z (w/Light &

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 50, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2 (Refresh), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed), Voltage: 5 (24 VDC), Electrical Entry: G [Grommet (Lead Wire Length

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 40, Flange Type: KF (NW), Valve Direction: G (w/Indicator, Rear Flange Surface), Version: 2 (Refresh), Auto Switch: M9P--Solid State, Gen.

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 63, Flange Type: D [K (DN)], Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2 (Refresh), Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: G [Grommet (Lead Wire Length 300mm)], Surge Suppressor: Z

Valve Type: XLFV (Normally Closed, O-ring Seal), Flange Size: 25, Flange Type: KF (NW), Valve Direction: F (w/Indicator, Left Flange Surface), Version: 2 (Refresh), Auto Switch: M9// (w/o Auto Switch w/Built-in Magnet), Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 5 (24 VDC), Electrical Entry: G [Grommet (Lead Wire Length 300mm)], Surge Suppressor: Z (w/