Valve Type: Smooth Exhaust, Normally Closed, Bellows, O-ring Seal, Flange Size: 40, Flange Type: KF (NW), Valve Direction: w/o Indicator, Rear Flange Surface; Std. Indicator, Rear Flange Surface, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Voltage: 24 VDC, Electrical Entry: M
Item Display Content Setting of connection product [4L] 4 L range [16L] 16 L range [40L] 40 L range [PFW] is selected [100L] 100 L range [250L] 250 L range [10L] 10 L range [rAnG] [50L] 50 L range Selection of flow range [100L] 100 L range [PFA] is selected [200L] 200 L range [500L] 500 L range [4L] 4 L range [PFd] is selected [16L] 16 L range [40L] 40 L range Press the SET button to set.
Rated flow range of sensor Set flow rate range of sensor Sensor 4L/min 20L/min 40L/min 1.8L/min 0.4L/min Flow rate range 10L/min 0.4L/min 4L/min PF2D504 0.25L/min 4.5L/min 1.8L/min 20L/min PF2D520 1.3L/min 21L/min 4L/min 40L/min PF2D540 2.5L/min 45L/min Flow Rate Characteristics (Pressure Characteristics) PF2D504 PF2D520 PF2D540 0.040 0.035 0.030 0.035 0.030 0.025 Pressure loss [MPa] Pressure
Applicable series AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS-10D AS-20D AS-25D AS-30D AS-40D AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Prepare DIN rail by user. Bracket for AS1002F-02 is not available.
Maximum flow rate: 40l/min, 80l/min. Features 1 Operating principle Flow flow Air flow Filtering Back-flushing Cylinder Cylinder The element compressed by the cylinder filters the fluid. As the cylinder extends downward, the element is decompressed. Air pressure forces the fluid in the reservoir out to the filter and back-flushes the element. Automatic back-flushing.
Applicable series AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS-10D AS-20D AS-25D AS-30D AS-40D AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Prepare DIN rail by user. Bracket for AS1002F-02 is not available.
Applicable model AS-10L AS1002Fm AS-20L AS2002Fm AS-25L AS2052Fm AS-30L AS3002Fm AS-40L AS4002Fm Part no.
Applicable series AS-10D AS-20D AS-25D AS-30D AS-40D AS-12L AS-10L AS-20L AS-25L AS-30L AS-40L AS1002F-02 AS1002F AS2002F AS2052F AS3002F AS4002F AS1002F AS2002F AS2052F AS3002F AS4002F DIN rail mounting bracket L-bracket Bracket for AS1002F-02 is not available. Prepare DIN rail by user.
Applicable model AS-10L AS1002FS AS-20L AS2002FS AS-25L AS2052FS AS-30L AS3002FS AS-40L AS4002FS Part no.
Floating with flat bar Floating with round bar Bracket +0.3 40+0.1 112 +0.3 20+0.1 150 Floating bracket positioning pin (10 x 18L) Bracket mounting hole (80) Hexagon socket head cap screw (M10 x 1.5 x 40L) Bracket mounting hole (100) Hexagon socket head cap screw (M12 x 1.75 x 40L) Support bracket 31 18 C B A Hexagon socket head cap screw tightening torque Unit: Nm Applicable cylinder MY1B
PF2A30 series PF2A31 series 1 to 10 L/min type (PF2A510) 5 to 50 L/min type (PF2A550) [11L]: [21L]: [51L]: 10 to 100 L/min type (PF2A511) 20 to 200 L/min type (PF2A521) 50 to 500 L/min type (PF2A551) [10L]: [50L]: PF2W30 series PF2W33 series [11L]: 10 to 100 L/min type (PF2W511) 0.5 to 4 L/min type (PF2W504) [04L]: [20L]: [40L]: 2 to 16 L/min type (PF2W520) 5 to 40 L/min type (PF2W540) PF2D30
PF2A20 series 1 to 5 to 10 L/min type (PF2A510) 50 L/min type (PF2A550) [10L]: [50L]: [11L]: [21L]: [51L]: 10 to 20 to 50 to 100 L/min type (PF2A511) 200 L/min type (PF2A521) 500 L/min type (PF2A551) PF2W20 series 0.5 to 4 L/min type (PF2W504) (PF3W504) [04L]: [20L]: [40L]: [11L]: 2 to 5 to 16 L/min type (PF2W520) (PF3W520) 40 L/min type (PF2W540) (PF3W540) 10 to 100 L/min type (PF2W511)
thread Supply port RcNPTG 1/8 Female thread Port size Pilot air Exhaust port M50.8 Female thread Body wetted areas Polypropylene(PP), Stainless steel(SUS316) Diaphragm PTFE Check valve PTFE, Polypropylene(PP) Material Liquid contact seals FKM Maximum discharge rate 2000mL/minNote1) 1000mL/minNote1) Average discharge pressurer 0 to 0.6MPa Pilot air pressure 0.2 to 0.7MPa Air consumption 40L
CL Bore size (mm) 20, 25, 32 40, 50, 63 80, 100 Thread size Pulling force Stroke (mm) MLGC M2.5 X 0.45 X 25l 4.9N 2 M3 X 0.5 X 3l 10N 3 CNA M5 X 0.8 X 40l 24.5N 3 Bolt should be detached under normal operation, otherwise it may cause malfunction of the locking feature. CB wThe lock piston is pushed further upward.
Element dimension 65 x 250mm 65 x 500mm Fluid Cleaning solvent, Coolant Note 1) Operating pressure Maximum 1.0MPa No need to replace filter element No generation of industrial waste (clogged element) Fluid temperature Maximum 80C (176 F) Flow rate Note 2) 40L/min 80L/min Port size Rc 1 (IN, OUT, DRAIN) Material Case and cover: SUS304; O-ring: NBR/FPM 2 types of element (cylindrical type
Pulling force N 4.9 Stroke (mm) Bore size (mm) Thread size Rubber cap M2.5 x 0.45 x 25l or more 2 20, 25, 32 M3 x 0.5 x 30l or more 3 40, 50, 63 10 M5 x 0.8 x 40l or more 3 80, 100 24.5 Remove the bolt for normal operation. It can cause lock malfunction or faulty release. 2. Locking type While pushing the M/O knob, turn it 90 counterclockwise.
M3 x 0.5 x 30l or more 40, 50, 63 10N 3 M5 x 0.8 x 40l or more 80, 100 24.5N 3 Remove the bolt for normal operation. It can cause lock malfunction or faulty release. 2. Locking type manual release While pushing the M/O knob turn it 90 counter clockwise. The lock is released (and remains in a released state) by aligning the mark on the cap with the OFF mark on the M/O knob.
Supply Unit: W (Flow Adjustment Valve + Stop Valve), Rated Flow Range: 40 (5~40L/min), Thread: N (NPT), Port Size: 06 (3/4)
Supply Unit: W (Flow Adjustment Valve + Stop Valve), Rated Flow Range: 40 (5~40L/min), Thread: N (NPT), Port Size: 04 (1/2)